Air Conditioner Leaking Water: Causes and What to Do
Hertfordshire, Bedfordshire & Cambridgeshire
An air conditioner leaking water from the indoor unit almost always has a problem with the water it removes from the air: a blocked or kinked condensate drain, a failed condensate pump, a dirty filter that lets the coil ice up and then overflow, or a unit that is not level. Switch it off, protect the floor and check the filter, then call an F-Gas registered engineer if the leak comes back. Water dripping from the outdoor unit while it is heating is usually normal.
- Air conditioners pull moisture out of the air when cooling. That water has to drain away through a pipe or be pumped out.
- A leak from the indoor unit usually means the water is not getting away: a blockage, a kink, a failed pump or a unit that has tilted.
- A clogged filter can make the coil ice over. When the ice melts, it can overflow the drip tray.
- Clean the filter yourself if the user manual allows. Leave the drain, pump and refrigerant to an engineer.
- Water from the outdoor unit in heating mode is normal defrost water.

Why an air conditioner makes water at all
When an air conditioner cools, warm room air is blown across the indoor coil, which is very cold. The moisture in the air condenses on the coil, just as it does on a cold glass of water on a summer day. The water runs into a drip tray under the coil and away through a condensate pipe, either by gravity to an outside wall or drain, or with a small pump where gravity will not work.
On a humid day, a split system can remove a surprising amount of water. As long as the drain is clear and the pump works, you never see it. When something stops that water getting away, it has only one place to go: out of the front or bottom of the indoor unit, and down your wall.
Is the leak normal? Where is the water?
| Where you see water | Mode | Is it normal? | Likely cause |
|---|---|---|---|
| Dripping from the indoor unit onto the wall or floor | Cooling or dry | No | Blocked drain, kinked pipe, failed pump, unit not level |
| Water spitting from the indoor unit’s air outlet | Cooling | No | Dirty filter or coil, or low refrigerant causing icing |
| Dripping from the outdoor unit or its base | Heating | Yes | Defrost water from the outdoor coil |
| Water dripping from the pipe end outside | Cooling | Yes | Condensate draining correctly |
| Water running down the pipework insulation | Cooling | No | Damaged or missing insulation on the refrigerant pipes |
| Damp patch on the wall behind the unit | Any | No | Leaking drain joint inside the wall or behind the unit |
In heating mode, the outdoor unit becomes the cold side. Frost and ice build up on its coil in cold, damp weather, and the unit regularly runs a short defrost cycle to melt it. The water drips from the base of the outdoor unit. That is normal, but it should drain somewhere sensible, not onto a path where it can freeze.
What to do right now
- Switch the unit off with the remote, then at its isolator if water is anywhere near the electrics.
- Protect the area. Put towels or a tray under the unit and move electrical items and furniture out of the way.
- Check the filter. Most wall-mounted indoor units have washable filters behind the front panel. If your user manual shows how to remove and clean them, do so. A heavily clogged filter is one of the most common causes of icing and leaks.
- Check the outside end of the drain pipe. Find where the condensate pipe comes out, often on an outside wall near the unit. Make sure the end is not blocked by leaves, soil, a plant pot or ice, and that the pipe is not squashed or kinked.
- Listen for a pump. If your unit has a condensate pump, often in a small box or trunking near the indoor unit, you may normally hear it run. Silence while the unit is leaking can point to a failed pump.
- Let it dry and try again. If the filter was the problem, run the unit in cooling mode later and watch it. If the leak returns, call an engineer.
Our air conditioning repair engineers deal with leaking indoor units across Hertfordshire, Bedfordshire and Cambridgeshire.
What not to do
- Do not open the refrigerant circuit, add refrigerant or undo pipe connections. Handling refrigerant is legally restricted to F-Gas certified engineers.
- Do not take the casing off the indoor or outdoor unit beyond the filter panel your user manual describes. There are live electrical parts inside.
- Do not poke wire or rods up the condensate pipe from the unit end. It is easy to puncture the drip tray or dislodge the drain connection.
- Do not keep running a leaking unit. Water near the electrics and inside a wall can do real damage.
The common causes explained
| Cause | What you might notice | Can you fix it yourself? | What the engineer does |
|---|---|---|---|
| Blocked condensate drain | Leak from the indoor unit in cooling mode, sometimes a musty smell | Only a blockage at the outside end | Clears the drain, trap and tray, flushes the line and checks the fall |
| Kinked, sagging or badly sloped pipe | Leak started after decorating or moving furniture, or has always happened | You can free a visibly squashed pipe outside | Re-routes or re-clips the pipe with a continuous fall |
| Failed condensate pump | Leak with no pump noise, or the unit shuts down with a warning | No | Tests the pump and float switch, cleans or replaces it |
| Dirty filter causing icing | Weak airflow, ice on the coil, leak after the unit switches off | Yes, clean the filter as the manual describes | Cleans the coil and checks airflow |
| Low refrigerant | Icing even with a clean filter, poor cooling | No | Finds and repairs the leak, then recharges |
| Unit not level or bracket moved | Water runs out of one end of the unit | No | Re-levels the unit and checks the drip tray |
| Cracked or dirty drip tray | Steady leak regardless of the drain | No | Cleans or replaces the tray |
| Poor pipe insulation | Water running along the pipes from outside the unit | No | Replaces damaged insulation on the refrigerant pipes |
Blocked condensate drains
This is the most common cause. Dust, mould and slime build up in the drip tray and drain over time, especially if the filters have not been cleaned often. Fujitsu’s service manual for its wall-mounted units lists checking the drain hose connection, the trap and whether the hose is clogged among the first steps when an indoor unit is leaking. A professional clean clears the tray and the full length of the pipe and checks it drains freely.
Condensate pump failure
Where the indoor unit sits on an inside wall, or the drain has to run upwards, a small pump lifts the water away. Pumps have a float switch that turns them on as water collects. If the pump fails or the float sticks, the tray overflows. Some systems are wired so the unit stops when the pump’s safety switch trips, which avoids a leak but can look like a breakdown.
Icing from a dirty filter or low refrigerant
If air cannot pass freely over the indoor coil, the coil gets colder than it should and the condensate freezes on it. When the unit stops or goes into a defrost, the ice melts faster than the tray can drain it, and water pours out. A clogged filter is the usual reason. If the filter is clean and the coil still ices, low refrigerant is a likely cause, and that means a leak in the refrigerant circuit that must be found and repaired by an F-Gas engineer.
Installation faults
A leak that has been there since the day the unit was fitted usually points to the installation: a drain without enough fall, an unsealed joint behind the unit, or an indoor unit that is not level. Our guide on how to choose an air conditioning installer explains what a good installation should include.
What an engineer will check
- The filters, coil and fan, and whether the coil has iced
- The drip tray, drain connection and full length of the condensate pipe
- The fall on the pipe, and any traps or sags where water sits
- The condensate pump and its float switch, if fitted
- That the indoor unit is level and firmly fixed
- The refrigerant pressures and system performance, if icing is suspected
- The condition of the insulation on the refrigerant pipes
How to stop it happening again
- Clean the filters as often as the user manual says, more often if the unit runs every day in summer.
- Keep the outside end of the drain pipe clear and away from soil and plant pots.
- Have the system serviced regularly. A service includes cleaning the coil, drip tray and drain, which is where most leaks start. Our air conditioning servicing page explains what we do.
- Do not block the airflow in front of the indoor unit with shelves or curtains.
What it costs with Vantage
In normal working hours there is no call-out fee. After the first hour, time is charged in half-hour steps, and parts such as a condensate pump are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive. We are Refcom F-Gas registered (REF1024550), so our engineers can legally work on the refrigerant side of your system if the leak turns out to be caused by low refrigerant.
Frequently asked questions
Is it dangerous if my air conditioner is leaking water?
The water itself is only condensation, but it can be dangerous if it reaches electrical sockets, cables or the unit’s own electrics. Switch the unit off and keep water away from anything electrical until it has been checked.
Why is my air conditioner leaking water only in heating mode?
If the water is coming from the outdoor unit, that is normal defrost water. If water is coming from the indoor unit in heating mode, that is unusual, because the indoor coil is hot and should not produce condensate, so it needs an engineer to look at it.
Can a dirty filter make an air conditioner leak?
Yes. A clogged filter cuts the airflow, the indoor coil gets too cold and ices over, and when the ice melts it can overflow the drip tray. Cleaning the filter as the user manual shows is often the fix.
Why does my air conditioner leak water when it is turned off?
Often the coil iced up while running, and the ice melts after the unit stops. It can also be water that built up behind a blockage finally running out. Either way, the cause needs finding.
How often should air conditioning be serviced to prevent leaks?
For most home systems, a service once a year is a sensible minimum, with filters cleaned more often by you in between. Check your manufacturer’s guarantee terms too, as they may set their own service interval.
When to call an engineer
If you have cleaned the filter and the leak comes back, or you can see ice on the coil, hear no pump or see water running inside the wall, switch the system off and call our air conditioning repair team on 01462 506374. The phone is answered 24 hours a day, 7 days a week.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Air conditioning near you
Want air con fitted? We install and service it across the area
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374