Air conditioning ducting is the network of insulated ducts that carries cooled or heated air from a hidden indoor unit, usually in a ceiling void or loft, to grilles in one or more rooms, and brings air back to the unit to be treated again. Most UK homes do not need it, because a ductless wall-mounted split system cools a room with no ductwork at all, but ducting is the right answer when you want the equipment completely out of sight, in offices, shops, new builds, extensions and loft conversions with space above the ceiling.

In short

  • Ducting moves conditioned air. It is not the same as the refrigerant pipes that link the indoor and outdoor units.
  • A ducted system hides the indoor unit and shows only grilles, so it suits projects where ceilings are open or being built.
  • Duct size, length, bends and insulation decide whether a ducted system is quiet and efficient or noisy and weak.
  • Cold ducts running through a warm loft must be properly insulated, or they drip condensation onto ceilings.
  • The flexible hose on a portable air conditioner is an exhaust, not true ducting, and should not be lengthened beyond the manufacturer’s limit.
Wall mounted air conditioning unit installed by Vantage in a lounge
A wall-mounted air conditioning unit we installed in a lounge.

What counts as air conditioning ducting

People use the word for three different things, so it helps to separate them:

  • Ductwork for a ducted air conditioning system. Rigid or flexible ducts that distribute air from a concealed fan coil unit to ceiling or wall grilles. This is what installers mean by ducted air conditioning.
  • The exhaust hose on a portable unit. A single flexible hose that pushes hot air out of a window. It carries waste heat away rather than distributing cool air.
  • Fresh air and ventilation ducting. Ducts that bring outside air into a building or extract stale air. Some commercial systems combine this with cooling, but a standard split air conditioner does not bring in fresh air.

What ducting is not: the pair of copper refrigerant pipes, the cable and the condensate drain that run between the indoor and outdoor units of a normal split system. Those are called the line set or pipework, and they are covered in our guide to air conditioning installation.

How a ducted air conditioning system works

A ducted system is a split system with a different kind of indoor unit.

  1. The outdoor unit holds the compressor and condenser, exactly as on a wall-mounted system.
  2. Refrigerant pipes run to a fan coil unit hidden in a ceiling void, loft, bulkhead or cupboard.
  3. The fan coil pulls air across a coil that the refrigerant cools (or warms in heating mode).
  4. The treated air is pushed into a plenum box and along supply ducts to diffusers or grilles in each room or zone.
  5. Air returns to the unit through a return grille, often in a hallway or ceiling, passing through a filter on the way.
  6. Water taken out of the air drains away through a condensate pipe, or is lifted by a small condensate pump where there is no fall.

Because only the grilles and a wall controller are visible, ducted systems are popular in offices, meeting rooms, retail units, hotels and high-end home projects. For business premises see our commercial air conditioning service.

The main types of ducting

Duct typeWhere it is usedStrengthsWatch out for
Rigid rectangular sheet metalCommercial ceilings, plant roomsSmooth airflow, durable, easy to clean through access panelsNeeds space and careful support
Rigid circular (spiral) steelMain runs in offices and larger homesEfficient, strong, low air leakage when sealedBends and fittings add resistance
Semi-rigid or flexible insulated ductShort final runs to grilles, loftsEasy to route around joists and obstructionsKinks, sags and long runs choke airflow and add noise
Plastic or PVC ductExtract fans, portable unit hosesCheap and lightNot suited to cold conditioned air without insulation

A good design usually combines rigid ducting for the main run with short, straight flexible connections to each grille.

Design details that decide whether it works

Airflow and static pressure

Every duct, bend, grille and filter resists the air. Ducted indoor units are rated by how much resistance (called external static pressure) their fan can overcome. If the ducts are too small, too long or full of tight bends, the fan cannot move enough air. The result is a unit that runs flat out, sounds noisy, cools some rooms and not others, and can freeze its coil. The installer should size ducts from the airflow the unit needs, not from what fits.

Insulation and condensation

In cooling mode the air inside the ducts is cold. Where those ducts pass through a warm, humid loft or ceiling void, moisture condenses on the outside of any uninsulated or poorly sealed section and drips onto plasterboard. Supply ducts need continuous insulation with a sealed vapour barrier, and joints need sealing, not just taping loosely.

Noise

Air rushing through undersized ducts and grilles creates noise. Correct sizing, flexible connections to reduce vibration and good grille selection keep a ducted system quiet enough for bedrooms and meeting rooms.

Access for maintenance

The fan coil, filter and condensate pump need to be reachable. Plan an access hatch or removable ceiling tile before the ceiling goes up, not after.

Ducted or ductless: which suits you

Ducted systemWall-mounted split (ductless)
What you seeGrilles and a controllerAn indoor unit on the wall
Building workNeeds ceiling void or loft space, usually during a build or renovationMinimal, a small hole for pipework
Rooms servedOne unit can serve several rooms or a zoneOne indoor unit per room (or multi-split)
EfficiencyCan lose some performance through ducts if poorly designedAir is treated in the room itself
MaintenanceFilters, ducts, grilles and condensate pumpFilters and indoor unit cleaning
Best forOffices, shops, new builds, extensionsMost existing homes

For most homes in Hertfordshire, a wall-mounted split or a multi-split is simpler and more efficient. Ducted makes sense when ceilings are already down, when appearance matters most, or when a single unit needs to serve an open-plan or commercial space.

Portable air conditioner hoses

A portable air conditioner has the compressor inside the room, so it must dump its heat outside through a hose. A few practical points:

  • Keep the hose as short and straight as possible. A long or kinked hose makes the unit work harder and pushes heat back into the room.
  • Do not extend the hose beyond the length the manufacturer allows, and do not swap in a narrower duct.
  • Seal the window gap with a proper window kit, otherwise warm air comes straight back in.
  • Expect it to be louder and less effective than a fixed split system. If you are using one every summer, a permanent system is usually the better long-term answer.

Looking after ducted systems

Leave refrigerant and electrical work to an engineer

  • Only F-gas qualified engineers may work on the refrigerant circuit, including connecting, repairing or recharging it.
  • Always isolate the power before opening a filter hatch or grille.
  • Do not remove the fan coil casing, disconnect the condensate pump or cut into ducts yourself.

What you can do safely:

  1. Clean or replace the return air filter as often as the manufacturer’s manual says, which is usually every few weeks in heavy use.
  2. Keep supply and return grilles clear of furniture and dust.
  3. Listen for the condensate pump running constantly or alarms on the controller, and report drips from ceilings straight away.
  4. Book a yearly service so the coil, drain, pump, controls and refrigerant circuit are checked. Our air conditioning servicing page explains what that covers.

For business premises in England and Wales, air conditioning systems with a combined effective rated output of more than 12kW must also have an energy inspection by an accredited energy assessor at least every five years.

How we price it

Installations are quoted as a fixed price after a free survey, so the price you agree is the price you pay. For ducted work the survey checks ceiling space, duct routes, return air paths, condensate falls and access, because those decide the design. You can start with our air conditioning quote.

Repairs and servicing are charged by time. In normal working hours there is no call-out fee. The first hour is charged at a set rate, after that time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive.

We are Refcom F-Gas registered (REF1024550), and brands we offer include Alpha, Panasonic and Fujitsu. Our labour carries a 12 month guarantee.

Frequently asked questions

Can I install air conditioning ducting myself?

A builder or competent DIYer can physically fit duct runs, but the system still needs an F-gas qualified engineer to install and commission the indoor unit and refrigerant circuit. In practice the ducts should be designed by the air conditioning installer, because the sizes and route have to match the unit’s airflow and static pressure rating.

What size ducting do I need for my air conditioner?

For a portable unit, use only the hose diameter and length the manufacturer supplies. For a ducted system, the size depends on the airflow each room needs and the length of each run, so it is calculated during design rather than picked from a chart.

Is ducted air conditioning noisy?

A well designed ducted system is very quiet because the fan coil sits away from the room. Noise usually means ducts or grilles that are too small, flexible duct that is kinked or too long, or a unit without proper anti-vibration mounting.

Do air conditioning ducts need cleaning?

Filters need regular cleaning, and grilles should be kept dust-free. Ducts themselves need inspection during servicing and cleaning if dust or debris has built up, which is more likely where filters have been neglected.

Can ducted air conditioning heat as well as cool?

Most modern ducted split systems are heat pumps and can run in heating mode as well as cooling. Check the heating capacity of the unit during design if you plan to rely on it in winter.

Ducted and split air conditioning across Hertfordshire

If you are planning an office fit-out, an extension or a loft conversion and want the air conditioning hidden, involve an installer before the ceilings are finished so ducts, access and drainage can be designed in. See our commercial air conditioning service or call 01462 506374 to arrange a free survey. The phone is answered 24 hours a day, 7 days a week.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.