There is no single national decibel limit for a home air conditioning unit in the UK. Instead, noise from the outdoor unit is controlled in three ways: planning rules, including the MCS 020(a) noise check that applies to permitted development in England, conditions your council may set if planning permission is needed, and statutory nuisance law if the unit disturbs your neighbours once it is running.

  • In England, air-to-air heat pumps that heat as well as cool can be installed under permitted development, if they meet conditions that include the MCS 020(a) noise standard.
  • Units used only for cooling, and installations on listed buildings, fall outside those rights and usually need planning permission.
  • Where permission is needed, councils often set noise limits relative to the existing background noise.
  • Any unit, permitted or not, can be a statutory nuisance under the Environmental Protection Act 1990 if it is too loud.
  • Careful siting, anti-vibration mounts and good maintenance make the biggest difference to noise.
Wall mounted air conditioning unit installed by Vantage in a lounge
A wall-mounted air conditioning unit we installed in a lounge.

Why the outdoor unit is the part that matters

A split air conditioning system has two halves. The indoor unit on your wall is usually quiet, especially on its lowest fan speed or night mode. The outdoor unit holds the compressor and a large fan, and that is the part that can be heard next door. Planning rules and noise complaints are almost always about the outdoor unit.

Our air conditioning installation service starts with where the outdoor unit can go legally and quietly, before we look at anything else.

Planning and permitted development in England

Permitted development for air-to-air units

Since 29 May 2025, air-to-air heat pumps, the type most home air conditioning systems are, have been able to use the same permitted development rights in England as other air source heat pumps. That means you may not need planning permission, as long as the installation meets the conditions. According to the Planning Portal and the legislation, these include:

ConditionWhat it means
Must comply with MCS 020(a)The installation must pass the noise calculation in the MCS planning standard, whether or not the installer is MCS certified
Not used solely for coolingA unit that only cools does not qualify
Size of the outdoor unitNo more than 1.5 cubic metres on a house, or 0.6 cubic metres on a block of flats
Number of unitsOne on a non-detached house or flat, up to two on a detached house
Not on a pitched roofOn a flat roof it must be at least one metre from the edge
Listed buildings and scheduled monumentsPermitted development does not apply
Conservation areasNot on a wall or roof facing a road, or nearer to that road than the house
Other areasNot above ground floor level on a wall facing a road
SitingPlaced, as far as practicable, to minimise its effect on the look of the building and the area

The rules are different in Scotland, Wales and Northern Ireland, which still use the earlier MCS 020 standard.

What the MCS 020(a) noise check does

MCS 020(a) is the planning standard that decides whether an air source heat pump is quiet enough to be permitted development. The installer takes the sound power level published for the product and works out the sound level at an assessment position linked to the nearest neighbouring habitable room, such as a bedroom or living room. The calculation allows for distance, for solid barriers between the unit and the window, and for reflective surfaces such as walls and corners that bounce sound back. If the result is over the limit, the unit either has to move, be screened or go through a full planning application.

When you need planning permission

You will usually need to apply if:

  • the unit is for cooling only
  • the property is listed, or the unit would break the conservation area or road-facing rules
  • the MCS 020(a) calculation fails
  • it is a commercial property
  • your council has removed permitted development rights in your area with an Article 4 direction

If you live in a flat, the lease will almost always need the freeholder’s consent for anything fixed to the outside, whatever the planning position.

How councils set noise limits

When a planning application is needed, the council’s environmental health team usually comments on noise. There is no single national figure. Many councils set limits relative to the existing background noise, because a unit that would go unnoticed on a busy road can be intrusive on a quiet cul-de-sac at night.

Westminster City Council, for example, asks for plant noise to be designed so that, measured one metre outside the nearest affected window, it is 10 dB below the lowest measured background level. Other councils use their own figures and methods, and many base their assessments on the British Standard used for rating industrial and commercial sound, BS 4142. For a planning application, the council may ask for a noise assessment with the manufacturer’s sound data and a plan showing distances.

Statutory nuisance: the rule that always applies

Even a unit that is fully permitted, or has planning permission, must not become a nuisance. Under section 79 of the Environmental Protection Act 1990, noise emitted from premises that is prejudicial to health or a nuisance is a statutory nuisance. Councils must take reasonably practicable steps to investigate complaints, and if they find a nuisance they can require it to stop.

Unlike planning, nuisance is judged on the real effect on your neighbours: how loud the unit is, when it runs, and what the area is normally like. A unit that runs all night in summer beside a neighbour’s bedroom window is the classic case.

Understanding decibels

Sound is measured in decibels, and air conditioning figures are usually given in dB(A), which is weighted to match how the human ear hears. The scale is logarithmic, which makes it easy to misread:

  • 3 dB more means twice the sound energy. Two identical units side by side are about 3 dB louder than one.
  • 10 dB more is heard as roughly twice as loud.
  • Distance helps. Out in the open, the sound level from a single unit drops by about 6 dB each time you double the distance from it.
  • Walls and corners hurt. Placing a unit in a corner or a narrow gap reflects sound and makes it louder.

Manufacturers publish two figures, and they are not the same. Sound power describes the noise the unit produces. Sound pressure is what you would measure at a particular distance. Only compare like with like.

How to keep an air conditioner quiet

Good siting checklist

  • Keep the outdoor unit as far as practical from neighbours’ bedroom and living room windows.
  • Avoid tight corners, narrow side passages and enclosed yards that reflect sound.
  • Mount it on a solid wall or a level ground base, not a thin partition wall or a lightweight fence.
  • Use anti-vibration mounts or pads so vibration does not travel into the structure.
  • Leave the clearances the manufacturer asks for, so the fan does not strain.
  • Consider a solid barrier between the unit and the nearest window where there is room.

Beyond siting:

  1. Choose a quiet model. Compare published sound power levels and look for a night or quiet mode on the outdoor unit.
  2. Size it correctly. An undersized unit runs flat out more of the time. A correctly sized inverter unit spends most of its time running gently.
  3. Keep it maintained. Worn fan bearings, loose panels and blocked coils all add noise. A regular air conditioning service keeps it running quietly.
  4. Deal with new noises quickly. Rattling, grinding or a unit that has become louder is a fault, not normal wear. Our air conditioning repair team can find the cause.

Leave this to the engineer

  • Do not open the outdoor unit’s casing or try to reposition a unit yourself. The refrigerant pipework is pressurised.
  • Anyone handling refrigerant must hold the right F-Gas qualification. We are Refcom F-Gas registered, REF1024550.

What it costs with Vantage

Air conditioning installations are quoted as a fixed price after a free survey, so the price you agree is the price you pay. The survey covers where the outdoor unit can go, whether permitted development applies and whether a noise calculation or planning application is needed. You can start with our air conditioning quote, and our guides on how to choose an air conditioning installer and what an air conditioning quote should include explain what a good survey covers.

For repairs and servicing, parts are quoted before we fit them, and every rate is published on our prices page.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Frequently asked questions

How loud can my air conditioner be?

There is no single legal decibel limit for home air conditioning in the UK. Under permitted development in England, the installation must pass the MCS 020(a) noise calculation at the nearest neighbouring window. If planning permission is needed, the council sets its own limit, and any unit can be treated as a statutory nuisance if it disturbs neighbours.

Do I need planning permission for air conditioning?

Not always. In England, air-to-air heat pumps that heat as well as cool can be installed under permitted development if they meet the conditions, including size, position and the MCS 020(a) noise check. Cooling-only units, listed buildings and many conservation area locations need permission.

Can my neighbour complain about my air conditioning unit?

Yes. Your neighbour can complain to the council, which must investigate. If the council decides the noise is a statutory nuisance, it can require you to stop it, which may mean moving, screening or replacing the unit.

Are air conditioning units noisy at night?

A modern, correctly sized inverter unit is usually quiet at night, and many have a night mode that lowers fan and compressor speed. Noise problems at night usually come from poor siting close to a bedroom window, reflections from nearby walls, or a unit that needs servicing.

Do the noise rules apply to commercial air conditioning?

Commercial premises fall outside the householder rules described here and usually need planning permission, often with noise conditions attached. Statutory nuisance law applies to commercial premises too.

Air conditioning advice in Hertfordshire, Bedfordshire and Cambridgeshire

If you want air conditioning that keeps you cool without upsetting the neighbours, our F-Gas registered engineers will survey your home, check the planning and noise position and find the right place for the outdoor unit. See our air conditioning installation service or call 01462 506374, answered 24 hours a day, 7 days a week.

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.

    Or get your air con price online now →