Air Conditioning Parts Explained: Compressors, Coils, Valves and More
Hertfordshire, Bedfordshire & Cambridgeshire
A split air conditioner has two halves: an outdoor unit containing the compressor, condenser coil, fan and expansion device, and an indoor unit containing the evaporator coil, fan, filters and control board, joined by insulated refrigerant pipes, a power and signal cable and a condensate drain. The compressor is the heart of the system, pumping refrigerant around the circuit so it can pick up heat indoors and release it outside.
In short
- The refrigerant circuit has four key parts: compressor, condenser, expansion valve and evaporator.
- The compressor does the hard work. Most home systems use an inverter-driven rotary compressor that speeds up and slows down to match demand.
- A reversing valve lets most modern systems run backwards to heat as well as cool.
- Fans, filters, sensors, the control board and the condensate drain are the parts most often involved in faults.
- Compressor failures are usually caused by something else, such as a leak, dirty coils or an electrical problem.
- All work on the refrigerant circuit must be done by an F-gas qualified engineer.

How the parts work together
Air conditioning does not make cold. It moves heat from inside to outside using a refrigerant that boils at a very low temperature.
- Compressor (outdoor unit). Squeezes low-pressure refrigerant vapour into a hot, high-pressure gas.
- Condenser coil (outdoor unit). The hot gas passes through a finned coil. The outdoor fan blows air across it, the refrigerant gives up its heat and condenses into a liquid.
- Expansion valve. The liquid passes through a restriction that drops its pressure sharply, which makes it very cold.
- Evaporator coil (indoor unit). The cold refrigerant flows through the indoor coil. The indoor fan blows room air across it, the refrigerant absorbs the heat and boils back into a vapour, and the cooled air returns to the room.
- The vapour returns to the compressor and the cycle repeats.
In heating mode, the reversing valve swaps the roles of the two coils, so the indoor coil gives out heat and the outdoor coil collects it from outside air.
A fault in any one of these parts stops the whole cycle working properly, which is why air conditioning repair starts with measuring pressures, temperatures and electrical signals rather than guessing at parts.
Outdoor unit parts
| Part | What it does | Common problems |
|---|---|---|
| Compressor | Pumps and pressurises refrigerant | Overheating, electrical faults, mechanical wear, often caused by other faults |
| Condenser coil | Releases heat to outside air | Blocked by leaves or dirt, bent fins, corrosion |
| Outdoor fan and motor | Moves air across the coil | Worn bearings, failed motor, debris |
| Reversing (four-way) valve | Switches between cooling and heating | Sticking, coil failure, stuck in one mode |
| Electronic expansion valve | Controls refrigerant flow and pressure drop | Sticking, faulty coil or signal |
| Service valves | Where the engineer connects gauges and isolates the circuit | Leaks at caps or seals |
| Inverter board and PCB | Drives the compressor and fan, runs protection | Power surges, moisture, component failure |
| Sensors (thermistors) | Measure pipe, coil and air temperatures | Drift or failure causing error codes |
Indoor unit parts
| Part | What it does | Common problems |
|---|---|---|
| Evaporator coil | Absorbs heat from room air | Dirt build-up, mould, icing from low airflow |
| Indoor fan | Cross-flow barrel fan that moves room air | Dust and mould on blades, motor faults, noise |
| Filters | Catch dust before it reaches the coil | Clogging, the most common cause of poor cooling |
| Louvres and swing motor | Direct the airflow | Stuck louvre, failed swing motor |
| Drain tray | Collects water from the coil | Blockage, sludge, overflow |
| Control PCB and receiver | Runs the unit, receives remote signals | Error codes, no response to remote |
| Room sensor | Reads room temperature | Unit cycles oddly or ignores the set point |
Connecting parts
- Refrigerant pipes. Two insulated copper pipes, one larger than the other, link the units. Flare or brazed joints must be made and tested correctly, because poor joints are a common source of slow leaks.
- Interconnecting cable. Carries power and communication between the units.
- Condensate drain. Carries away water removed from the air. Some installations use a small condensate pump where the water cannot fall by gravity.
- Isolator. A local switch so the system can be made safe for servicing.
The compressor in detail
Types of compressor
- Rotary. Compact and quiet, and widely used in wall-mounted home systems. Many are twin rotary designs for smoother running.
- Scroll. Two interleaved spiral scrolls, one fixed and one orbiting. Common in larger split and commercial systems.
- Reciprocating. Piston-driven. Found in older and some specialist equipment, rarely in modern home air conditioning.
Inverter or fixed speed
Most modern systems are inverter-driven. The inverter board varies the compressor speed to match the load, so the system runs gently most of the time instead of switching fully on and off. That means steadier temperatures, quieter running and better efficiency. Older fixed-speed systems run the compressor at full speed and cycle it on and off, and often use start and run capacitors, which are a common failure point.
Signs of compressor trouble
- the outdoor fan runs but the air indoors is not cold
- the outdoor unit hums, clicks or trips the power
- repeated error codes relating to the compressor, high pressure or discharge temperature
- a loud knocking or grinding from the outdoor unit
These symptoms can also come from much cheaper faults, such as a failed sensor, a board fault or low refrigerant, so proper diagnosis matters before anyone suggests a new compressor.
Why compressors fail
Compressors rarely fail on their own. The usual root causes are:
- Low refrigerant from a leak, which reduces cooling of the compressor and can let it overheat.
- Dirty or blocked coils, which raise pressures and temperatures.
- Electrical problems, such as poor supply, loose connections or board faults.
- Moisture or contamination in the circuit after a poor installation or repair.
That is why a yearly service, which checks coils, pressures and electrics, protects the most expensive part of the system.
Leave the internals to an engineer
- Only F-gas qualified engineers may open or work on the refrigerant circuit. It is against the law to do so without the right qualification.
- Both units contain mains voltage, and inverter boards can hold a charge after the power is switched off.
- Do not remove casings, straighten fins with tools or spray cleaners into the units.
What you can check yourself
- Make sure the remote is set to cooling (or heating) at a sensible temperature, with fresh batteries.
- Check the power at the isolator and the consumer unit.
- Clean the indoor filters.
- Clear leaves and debris from around the outdoor unit.
- Note any error code or flashing light pattern, and the make and model from the rating label, before you call.
If those do not help, our air conditioning repair engineers can diagnose the fault.
Repair or replace?
A single failed fan motor, sensor, valve coil or drain pump is usually worth repairing. A compressor failure or major leak on an older system is a different decision. Consider:
- Age and condition. A system near the end of its life with corroded coils may not justify major work.
- Refrigerant. Systems that used R22 can no longer be serviced with it, and older R410A systems are becoming less common.
- Parts availability. Boards and compressors for older or less common models can be hard to source.
- Efficiency. A modern inverter system may use noticeably less electricity than an old fixed-speed unit.
If replacement makes sense, our air conditioning installation service quotes a fixed price after a free survey. We will explain the options honestly, including when a repair is the better choice.
What it costs with Vantage
Air conditioning diagnosis and repair visits are charged by time. In normal working hours there is no call-out fee. The first hour is charged at a set rate, after that time is charged in half-hour steps, and parts are quoted before we fit them, so you can decide before any work goes ahead. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page.
As a rough guide to the size of the bill, filters, sensors and drain pumps cost far less to replace than a fan motor or control board, and a compressor is the most expensive part of all. Regular air conditioning servicing is the best way to avoid that.
Frequently asked questions
What is the most important part of an air conditioner?
The compressor, because it drives the whole refrigerant cycle. It is also the most expensive part to replace, which is why keeping the coils clean and the refrigerant charge correct matters so much.
Where is the compressor on a split air conditioner?
In the outdoor unit. That is why split systems are quieter indoors than portable units, which have the compressor inside the room.
Can a single air conditioning part be replaced?
Yes. Fans, sensors, boards, valves, drain pumps and even compressors can be replaced individually. Any part in the refrigerant circuit needs an F-gas qualified engineer to recover, repair, pressure test, evacuate and recharge the system.
How do I know if my air conditioning compressor has failed?
Typical signs are warm air from the indoor unit while the outdoor fan runs, humming or tripping power, and compressor-related error codes. The same symptoms can come from cheaper faults, so have it diagnosed before assuming the worst.
How long do air conditioning parts last?
It depends on use, installation quality and maintenance. Filters, drain pumps and fan motors are the parts most likely to need attention during a system’s life, while a well maintained compressor often lasts as long as the system itself.
Air conditioning repairs in Hertfordshire, Bedfordshire and Cambridgeshire
If your system is not cooling, is leaking, or is showing an error code, our Refcom F-Gas registered (REF1024550) engineers can find the faulty part and quote before fitting it. See our air conditioning repair page or call 01462 506374. The phone is answered 24 hours a day, 7 days a week.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.