Air Conditioning Parts Explained: Compressors, Coils, Valves and More

Hertfordshire, Bedfordshire & Cambridgeshire

Fully Stocked Vans12 Month Labour GuaranteeGas Safe Registered 956889

A split air conditioner has two halves: an outdoor unit containing the compressor, condenser coil, fan and expansion device, and an indoor unit containing the evaporator coil, fan, filters and control board, joined by insulated refrigerant pipes, a power and signal cable and a condensate drain. The compressor is the heart of the system, pumping refrigerant around the circuit so it can pick up heat indoors and release it outside.

In short

  • The refrigerant circuit has four key parts: compressor, condenser, expansion valve and evaporator.
  • The compressor does the hard work. Most home systems use an inverter-driven rotary compressor that speeds up and slows down to match demand.
  • A reversing valve lets most modern systems run backwards to heat as well as cool.
  • Fans, filters, sensors, the control board and the condensate drain are the parts most often involved in faults.
  • Compressor failures are usually caused by something else, such as a leak, dirty coils or an electrical problem.
  • All work on the refrigerant circuit must be done by an F-gas qualified engineer.
Wall mounted air conditioning unit installed by Vantage in a lounge
A wall-mounted air conditioning unit we installed in a lounge.

How the parts work together

Air conditioning does not make cold. It moves heat from inside to outside using a refrigerant that boils at a very low temperature.

  1. Compressor (outdoor unit). Squeezes low-pressure refrigerant vapour into a hot, high-pressure gas.
  2. Condenser coil (outdoor unit). The hot gas passes through a finned coil. The outdoor fan blows air across it, the refrigerant gives up its heat and condenses into a liquid.
  3. Expansion valve. The liquid passes through a restriction that drops its pressure sharply, which makes it very cold.
  4. Evaporator coil (indoor unit). The cold refrigerant flows through the indoor coil. The indoor fan blows room air across it, the refrigerant absorbs the heat and boils back into a vapour, and the cooled air returns to the room.
  5. The vapour returns to the compressor and the cycle repeats.

In heating mode, the reversing valve swaps the roles of the two coils, so the indoor coil gives out heat and the outdoor coil collects it from outside air.

A fault in any one of these parts stops the whole cycle working properly, which is why air conditioning repair starts with measuring pressures, temperatures and electrical signals rather than guessing at parts.

Outdoor unit parts

PartWhat it doesCommon problems
CompressorPumps and pressurises refrigerantOverheating, electrical faults, mechanical wear, often caused by other faults
Condenser coilReleases heat to outside airBlocked by leaves or dirt, bent fins, corrosion
Outdoor fan and motorMoves air across the coilWorn bearings, failed motor, debris
Reversing (four-way) valveSwitches between cooling and heatingSticking, coil failure, stuck in one mode
Electronic expansion valveControls refrigerant flow and pressure dropSticking, faulty coil or signal
Service valvesWhere the engineer connects gauges and isolates the circuitLeaks at caps or seals
Inverter board and PCBDrives the compressor and fan, runs protectionPower surges, moisture, component failure
Sensors (thermistors)Measure pipe, coil and air temperaturesDrift or failure causing error codes

Indoor unit parts

PartWhat it doesCommon problems
Evaporator coilAbsorbs heat from room airDirt build-up, mould, icing from low airflow
Indoor fanCross-flow barrel fan that moves room airDust and mould on blades, motor faults, noise
FiltersCatch dust before it reaches the coilClogging, the most common cause of poor cooling
Louvres and swing motorDirect the airflowStuck louvre, failed swing motor
Drain trayCollects water from the coilBlockage, sludge, overflow
Control PCB and receiverRuns the unit, receives remote signalsError codes, no response to remote
Room sensorReads room temperatureUnit cycles oddly or ignores the set point

Connecting parts

  • Refrigerant pipes. Two insulated copper pipes, one larger than the other, link the units. Flare or brazed joints must be made and tested correctly, because poor joints are a common source of slow leaks.
  • Interconnecting cable. Carries power and communication between the units.
  • Condensate drain. Carries away water removed from the air. Some installations use a small condensate pump where the water cannot fall by gravity.
  • Isolator. A local switch so the system can be made safe for servicing.

The compressor in detail

Types of compressor

  • Rotary. Compact and quiet, and widely used in wall-mounted home systems. Many are twin rotary designs for smoother running.
  • Scroll. Two interleaved spiral scrolls, one fixed and one orbiting. Common in larger split and commercial systems.
  • Reciprocating. Piston-driven. Found in older and some specialist equipment, rarely in modern home air conditioning.

Inverter or fixed speed

Most modern systems are inverter-driven. The inverter board varies the compressor speed to match the load, so the system runs gently most of the time instead of switching fully on and off. That means steadier temperatures, quieter running and better efficiency. Older fixed-speed systems run the compressor at full speed and cycle it on and off, and often use start and run capacitors, which are a common failure point.

Signs of compressor trouble

  • the outdoor fan runs but the air indoors is not cold
  • the outdoor unit hums, clicks or trips the power
  • repeated error codes relating to the compressor, high pressure or discharge temperature
  • a loud knocking or grinding from the outdoor unit

These symptoms can also come from much cheaper faults, such as a failed sensor, a board fault or low refrigerant, so proper diagnosis matters before anyone suggests a new compressor.

Why compressors fail

Compressors rarely fail on their own. The usual root causes are:

  • Low refrigerant from a leak, which reduces cooling of the compressor and can let it overheat.
  • Dirty or blocked coils, which raise pressures and temperatures.
  • Electrical problems, such as poor supply, loose connections or board faults.
  • Moisture or contamination in the circuit after a poor installation or repair.

That is why a yearly service, which checks coils, pressures and electrics, protects the most expensive part of the system.

Leave the internals to an engineer

  • Only F-gas qualified engineers may open or work on the refrigerant circuit. It is against the law to do so without the right qualification.
  • Both units contain mains voltage, and inverter boards can hold a charge after the power is switched off.
  • Do not remove casings, straighten fins with tools or spray cleaners into the units.

What you can check yourself

  1. Make sure the remote is set to cooling (or heating) at a sensible temperature, with fresh batteries.
  2. Check the power at the isolator and the consumer unit.
  3. Clean the indoor filters.
  4. Clear leaves and debris from around the outdoor unit.
  5. Note any error code or flashing light pattern, and the make and model from the rating label, before you call.

If those do not help, our air conditioning repair engineers can diagnose the fault.

Repair or replace?

A single failed fan motor, sensor, valve coil or drain pump is usually worth repairing. A compressor failure or major leak on an older system is a different decision. Consider:

  • Age and condition. A system near the end of its life with corroded coils may not justify major work.
  • Refrigerant. Systems that used R22 can no longer be serviced with it, and older R410A systems are becoming less common.
  • Parts availability. Boards and compressors for older or less common models can be hard to source.
  • Efficiency. A modern inverter system may use noticeably less electricity than an old fixed-speed unit.

If replacement makes sense, our air conditioning installation service quotes a fixed price after a free survey. We will explain the options honestly, including when a repair is the better choice.

What it costs with Vantage

Air conditioning diagnosis and repair visits are charged by time. In normal working hours there is no call-out fee. The first hour is charged at a set rate, after that time is charged in half-hour steps, and parts are quoted before we fit them, so you can decide before any work goes ahead. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page.

As a rough guide to the size of the bill, filters, sensors and drain pumps cost far less to replace than a fan motor or control board, and a compressor is the most expensive part of all. Regular air conditioning servicing is the best way to avoid that.

Frequently asked questions

What is the most important part of an air conditioner?

The compressor, because it drives the whole refrigerant cycle. It is also the most expensive part to replace, which is why keeping the coils clean and the refrigerant charge correct matters so much.

Where is the compressor on a split air conditioner?

In the outdoor unit. That is why split systems are quieter indoors than portable units, which have the compressor inside the room.

Can a single air conditioning part be replaced?

Yes. Fans, sensors, boards, valves, drain pumps and even compressors can be replaced individually. Any part in the refrigerant circuit needs an F-gas qualified engineer to recover, repair, pressure test, evacuate and recharge the system.

How do I know if my air conditioning compressor has failed?

Typical signs are warm air from the indoor unit while the outdoor fan runs, humming or tripping power, and compressor-related error codes. The same symptoms can come from cheaper faults, so have it diagnosed before assuming the worst.

How long do air conditioning parts last?

It depends on use, installation quality and maintenance. Filters, drain pumps and fan motors are the parts most likely to need attention during a system’s life, while a well maintained compressor often lasts as long as the system itself.

Air conditioning repairs in Hertfordshire, Bedfordshire and Cambridgeshire

If your system is not cooling, is leaking, or is showing an error code, our Refcom F-Gas registered (REF1024550) engineers can find the faulty part and quote before fitting it. See our air conditioning repair page or call 01462 506374. The phone is answered 24 hours a day, 7 days a week.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.

    Or get your air con price online now →