Air Conditioning Refrigerant Explained: R32, R410A, R22 and the Rules
Hertfordshire, Bedfordshire & Cambridgeshire
Air conditioning refrigerant is the fluid sealed inside the pipes between the indoor and outdoor units, which absorbs heat as it evaporates indoors and gives it out as it condenses outside. Most new home systems in the UK use R32, many older ones use R410A, and R22 can no longer be used to service existing equipment, and because the circuit is sealed a correctly installed system should never need topping up unless it has a leak.
In short
- Refrigerant is not used up. If a system is short of it, there is a leak that needs finding and fixing.
- R32 is the common refrigerant in new home split systems. It has a global warming potential of 675, less than a third of R410A at 2,088.
- R22 is an ozone-depleting substance and must not be used to service existing equipment.
- Only F-gas qualified engineers may handle refrigerant. DIY regas kits are not a legal or safe option.
- Larger systems above set thresholds need regular legal leak checks.
- The refrigerant type and charge are printed on the outdoor unit’s rating label.

What refrigerant actually does
Refrigerant is chosen because it boils at a very low temperature and can be switched between liquid and gas by changing its pressure. In the indoor coil it is at low pressure, so it boils and absorbs heat from the room air. The compressor then raises its pressure and temperature, and in the outdoor coil it condenses back to a liquid and releases that heat outside. An expansion valve drops the pressure again and the cycle repeats.
In heating mode, the same refrigerant runs the other way round, collecting heat from outside air and releasing it indoors.
The amount of refrigerant, called the charge, is set by the manufacturer for each system and adjusted for the length of the pipe run. Too little or too much and the system cools poorly, uses more electricity and puts strain on the compressor. That is why checking pressures and temperatures is part of every proper air conditioning service.
The main refrigerants you will come across
| Refrigerant | Type | Global warming potential | Where you find it | Status |
|---|---|---|---|---|
| R22 | HCFC, ozone-depleting | Not relevant, it is banned for servicing | Older systems, mostly installed before the mid 2000s | Must not be used to service existing equipment |
| R410A | HFC blend | 2,088 | Many systems from the 2000s and 2010s | Still serviced, but no longer allowed in new single split systems under 3kg |
| R32 | Single-component HFC | 675 | Most new home split systems | Current mainstream choice |
| R290 (propane) | Natural refrigerant | Very low | Many portable units and some newer products | Growing use, highly flammable, needs specific training |
Global warming potential (GWP) figures for R32 and R410A are from UK government F-gas guidance. GWP compares how much a gas warms the atmosphere with the same weight of carbon dioxide.
Why the industry moved to R32
UK F-gas rules ban new single split air conditioning systems containing less than 3kg of refrigerant with a GWP of 750 or more from 2025. R410A, at 2,088, is over that limit, while R32 at 675 is under it. R32 is also a single refrigerant rather than a blend, which makes it simpler to recover and reuse.
R32 is classed as mildly flammable, so installers need to follow the manufacturer’s rules on room size, charge and pipework, which is another reason installation is a job for trained engineers.
Can an R410A system be converted to R32?
Manufacturers do not approve putting R32 into a system designed for R410A. The components, charge and safety design are specific to each refrigerant. If an older R410A system fails badly, the choice is to repair it with R410A or replace it with a new system.
What if I still have an R22 system?
The rules on ozone-depleting substances say they must not be used to service existing equipment. An R22 system can keep running, but if it develops a leak or a compressor fault, it cannot be recharged with R22, and replacement is usually the only sensible option. If you have an older system and are not sure what it uses, the rating label on the outdoor unit will tell you.
The law on refrigerant: F-gas in plain English
- Qualified engineers only. It is against the law to install, service, repair, leak check or recover refrigerant from air conditioning without the right F-gas qualification. Companies doing this work also need company certification. We are Refcom F-Gas registered (REF1024550).
- Leak checks on larger systems. A system containing F gas equivalent to 5 tonnes of CO2 or more must be leak checked at least every 12 months, and every 6 months from 50 tonnes. To work it out, multiply the charge in kilograms by the GWP and divide by 1,000. For R32 the 5 tonne threshold is about 7.4kg, which almost no single-room home system reaches. For R410A it is about 2.4kg, which some larger systems exceed.
- No venting. Refrigerant must be recovered by an engineer when a system is repaired or removed. It must never be released to the air.
- Portable units. Movable room air conditioners containing HFCs with a GWP above 150 are banned from sale, which is why most portable units now use natural refrigerants.
Does air conditioning need regassing?
No, not as routine maintenance. Unlike a car air conditioning system, which runs flexible hoses and moving seals, a split system is a sealed circuit of copper pipes and brazed or flared joints. If it is short of refrigerant, it has leaked.
Signs of low refrigerant:
- the system runs for long periods but the room never gets properly cool
- ice or frost on the indoor coil or the pipes at the outdoor unit
- a hissing or bubbling noise near the pipework
- error codes related to low pressure or high discharge temperature
- oily residue around pipe joints or service valves
The correct fix is to find the leak, repair it, pressure test the circuit, evacuate it with a vacuum pump and then recharge it with the correct weight of refrigerant. Simply adding more refrigerant without finding the leak wastes money and releases more gas into the atmosphere.
Stay safe around refrigerant
- Never buy or use DIY regas kits or cylinders. Handling refrigerant without the right qualification is against the law.
- Refrigerant escaping as liquid can cause frostbite on skin and eyes.
- If you suspect a large leak indoors, switch the system off, ventilate the room and keep ignition sources away, particularly with R32 or R290 systems.
- Do not remove service valve caps or loosen pipe joints.
Choosing a refrigerant when you replace a system
For a new home system, the refrigerant is chosen by the manufacturer, not by you, and it will almost always be R32 for wall-mounted split systems. What matters more is that the system is:
- sized properly for the room
- installed with the correct pipe lengths and a proper pressure test and vacuum
- charged by weight to the manufacturer’s figure
- serviced every year
Brands we offer include Alpha, Panasonic and Fujitsu. See our air conditioning installation page for how we survey and quote, or our air conditioning repair page if your existing system has a leak.
What it costs with Vantage
Leak finding, repair and servicing are charged by time. In normal working hours there is no call-out fee. The first hour is charged at a set rate, after that time is charged in half-hour steps, and refrigerant and parts are quoted before we use them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive.
New systems are quoted as a fixed price after a free survey, so the price you agree is the price you pay. You can start with our air conditioning quote.
Frequently asked questions
What refrigerant does my air conditioning use?
Look at the rating label on the outdoor unit. It shows the refrigerant type, the factory charge in kilograms and often the CO2 equivalent. If the label is missing or faded, an engineer can identify it from the model number.
Is R32 refrigerant safe?
Yes, when installed and serviced correctly. It is classed as mildly flammable, so manufacturers set rules on room size, charge and installation that trained engineers follow.
How often does air conditioning need refrigerant topping up?
It should never need topping up. The circuit is sealed, so a shortage means a leak, which should be found and repaired before the system is recharged.
Can I still get R22 for my old air conditioner?
No. R22 is an ozone-depleting substance and must not be used to service existing equipment. An R22 system can run until it fails, but it cannot be recharged, so plan for replacement.
Do I need a leak check certificate for home air conditioning?
Most single-room home systems using R32 hold far less than the 5 tonne CO2 equivalent threshold, so a legal leak check is not required. A yearly service is still recommended and is often a condition of the manufacturer’s warranty.
Air conditioning servicing across Hertfordshire, Bedfordshire and Cambridgeshire
If your system is not cooling like it used to, or you think it has lost refrigerant, book a service or repair with an F-gas qualified engineer rather than a top-up. See our air conditioning servicing page or call 01462 506374. The phone is answered 24 hours a day, 7 days a week.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Air conditioning near you
Want air con fitted? We install and service it across the area
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374