Air Conditioning Regulations Explained: F Gas, TM44 and More
Hertfordshire, Bedfordshire & Cambridgeshire
The main air conditioning regulations in the UK are the F gas rules, which control who can install, service and leak check a system and how often larger systems must be checked, and, for buildings other than homes, the Energy Performance of Buildings Regulations, which require systems over 12 kW to have a TM44 energy inspection at least every five years. On top of that, planning, electrical safety and noise rules can apply depending on where the system goes.
- Anyone who installs, services, repairs, leak checks or recovers refrigerant from an air conditioner must hold the right F gas qualification, and companies doing this work for others need F gas company certification.
- Systems containing refrigerant equal to 5 tonnes of CO2 or more need regular leak checks and records, and the owner or operator is responsible.
- New single split systems under 3 kg can no longer use refrigerants with a global warming potential of 750 or more.
- Air conditioning in non-domestic buildings with a combined output over 12 kW needs a TM44 inspection at least every five years. Homes are not covered.
- Planning permission is often not needed for a small home, but there is no blanket rule, and new electrical circuits must meet Part P.

Who the rules apply to
It helps to separate three groups:
- Installers and engineers, who need personal F gas qualifications.
- Companies, which need F gas company certification if they install, repair, maintain or decommission systems for other people.
- Owners and operators, usually the business or landlord responsible for the system, who must make sure leak checks are done and records kept once a system is above the size thresholds.
Homeowners with a typical single room split system have far fewer duties, but the rules still protect them: only a qualified engineer from a certified company should install or work on the refrigerant circuit. For businesses, our commercial air conditioning team carries out the servicing and leak checks the rules call for.
F gas rules: qualifications and certification
F gases are the fluorinated greenhouse gases used as refrigerants in most air conditioning and heat pump systems. Great Britain’s F gas regulations aim to stop them escaping into the atmosphere.
Government guidance says you must hold your own qualification to work on equipment containing F gas, even if you work for someone else. That covers installing new systems, servicing and maintaining them, checking for leaks, recovering gas and decommissioning old systems.
Companies that install, repair, maintain or decommission stationary F gas equipment for others must also hold company certification, renewed every three years. For refrigeration and air conditioning, the certification bodies listed by the government are Refcom, the F-Gas Register (Quidos) and Bureau Veritas. Working without the correct certification can lead to a civil penalty.
We are Refcom F-Gas registered (REF1024550). If you are choosing a contractor, ask for their company certificate number and check it. Our guide on choosing an air conditioning installer covers the other questions to ask.
Leak checks and CO2 equivalent
Leak check frequency is based on the amount of refrigerant in the system, converted into tonnes of CO2 equivalent (CO2e). You multiply the refrigerant charge in kilograms by its global warming potential (GWP), then divide by 1,000.
| Refrigerant in the system | Leak checks required | With a leak detection system fitted |
|---|---|---|
| Less than 5 tonnes CO2e | No mandatory leak checks | Not applicable |
| 5 to less than 50 tonnes CO2e | At least every 12 months | At least every 24 months |
| 50 to less than 500 tonnes CO2e | At least every 6 months | At least every 12 months |
| 500 tonnes CO2e or more | At least every 3 months, and a leak detection system must be fitted | At least every 6 months |
Hermetically sealed systems (factory sealed units) have no mandatory leak check until they contain 10 tonnes CO2e or more.
What that means in kilograms:
- R32, the most common refrigerant in new home and light commercial systems, has a GWP of 675. The 5 tonne threshold is reached at about 7.4 kg of R32, so most single room home systems are below it.
- R410A, used in many systems installed before R32 took over, has a GWP of roughly 2,090. The 5 tonne threshold is reached at about 2.4 kg, so larger R410A systems are more likely to need annual leak checks.
The refrigerant type and charge are on the label of the outdoor unit and in the installation paperwork.
When a leak is found it must be repaired as soon as possible, and the repair checked again within a month.
Records
Operators of equipment containing 5 tonnes CO2e or more must keep records, including the type and quantity of refrigerant installed and added, the dates and results of leak checks, any gas recovered, and the name and certificate number of the company that did the work. Records must be kept for five years.
Bans on certain refrigerants in new equipment
Some higher GWP refrigerants can no longer be used in new equipment:
- Single split systems. From 2025, new single split air conditioning systems containing less than 3 kg of F gas cannot use a refrigerant with a GWP of 750 or more. In practice, that rules out R410A in these new systems, while R32 (GWP 675) is still permitted.
- Portable (movable) air conditioners. HFC refrigerants with a GWP above 150 are already banned in these.
These bans apply to new equipment placed on the market. Existing systems can carry on running and be serviced.
Older R22 systems
R22 is an ozone depleting refrigerant found in older air conditioning. Government guidance says you can still use equipment containing ozone depleting substances as long as it is not leaking. However, R22 can no longer be used to service or top up systems, so when an R22 system develops a refrigerant leak, replacement is usually the only practical answer.
TM44 air conditioning inspections
The Energy Performance of Buildings (England and Wales) Regulations 2012, as amended in 2020, require air conditioning systems in buildings with an effective rated output over 12 kW to be inspected by an accredited energy assessor at least every five years. TM44 is the inspection method published by CIBSE (the Chartered Institution of Building Services Engineers), and the reports are commonly called TM44 inspections.
Key points:
- Outputs are added together. All the units in a building controlled by one person count as one system. Several small splits can easily add up to more than 12 kW.
- Who can inspect. Only an accredited energy assessor who is a member of a government approved scheme.
- What the report covers. The likely efficiency of the system, the adequacy of maintenance and controls, whether the system is sized correctly for the cooling load, and suggestions for improvement.
- Penalties. There are fixed penalties for not having a valid inspection report, and for not producing it when asked by an enforcement officer.
- Homes are not covered. The inspection rules do not apply to dwellings.
A TM44 inspection is separate from servicing. The inspection assesses energy efficiency; regular air conditioning servicing and leak checks keep the system running and legal.
Planning permission
In June 2026, the government’s housing department said that planning permission is not usually needed to install air conditioning on a small home if it would not materially affect the external appearance of the building, but that there is no blanket rule and people should check with their local council.
Extra care is needed for:
- Listed buildings, where listed building consent may be needed for any alteration.
- Conservation areas, where councils look more closely at anything visible from the street.
- Flats and leasehold properties, where the lease or freeholder’s consent often matters as much as planning.
- Commercial premises, where the council, landlord and building management may all have a say.
Electrical rules
Most fixed air conditioning needs its own electrical supply. In England, adding a new circuit is notifiable building work under Part P of the Building Regulations, so it must be done by an electrician registered with a competent person scheme or signed off by building control. The installation should be tested and certified to the wiring regulations. Our electrical installations team can handle this as part of an air conditioning project.
Noise and neighbours
There is no single noise limit for home air conditioning units, but councils can act against noise that amounts to a statutory nuisance under the Environmental Protection Act 1990. Choosing a quiet unit, positioning it away from neighbours’ windows and using anti-vibration mounts avoids most problems before they start.
Workplaces
Employers must keep indoor workplace temperatures reasonable under the Workplace (Health, Safety and Welfare) Regulations 1992. Air conditioning is one way to do that, and once installed it becomes part of the building services an employer should maintain.
What it costs with Vantage
Installations are quoted as a fixed price after a free survey, so the price you agree is the price you pay. For servicing, leak checks and repairs, there is no call-out fee in normal working hours, time after the first hour is charged in half-hour steps, and parts are quoted before we fit them. Every rate is published on our prices page, so you know what you will pay before we arrive.
Frequently asked questions
Do I need an F gas engineer to install air conditioning at home?
Yes, for any split system. Connecting the refrigerant pipes, pressure testing, evacuating and charging the system all involve the refrigerant circuit, which by law must be done by a qualified engineer working for an F gas certified company.
Does my home air conditioning need a yearly leak check by law?
Usually not. Mandatory leak checks start at 5 tonnes CO2e, which is about 7.4 kg of R32, and most single room home systems contain less. Regular servicing is still recommended to keep the system efficient and spot problems early.
Is a TM44 inspection required for homes?
No. TM44 inspections apply to air conditioning in buildings other than dwellings where the combined output is over 12 kW. Offices, shops, schools and similar buildings are the typical cases.
Are air conditioning units being banned in the UK?
No. The government has said that air conditioning units are not banned. What has changed is which refrigerants can be used in some new equipment, such as the limit for new single split systems under 3 kg.
Who is responsible for F gas compliance in a rented office?
The operator, usually whoever has actual control over how the system runs and is maintained, is responsible for leak checks and records. In a lease this may be the landlord or the tenant, so check the lease and agree it in writing.
Commercial air conditioning in Hertfordshire, Bedfordshire and Cambridgeshire
We install, service and leak check air conditioning for businesses and homes across the area. See our commercial air conditioning service or call 01462 506374, answered 24 hours a day, 7 days a week.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Air conditioning near you
Want air con fitted? We install and service it across the area
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374