The best bathroom lighting uses layers: an even main light for the whole room, bright shadow-free light at the mirror, and softer accent or night lighting for relaxing, all on separate switches or dimmers. Every light also has to suit its position, because bathrooms are divided into safety zones around the bath and shower, and each zone needs fittings with the right water protection (IP rating) installed to the wiring regulations.

In short

  • Plan three layers: general light, task light at the mirror and accent light for mood.
  • Light the face from the sides or front, not only from above, to avoid shadows when shaving or doing make-up.
  • Zone 0 is inside the bath or shower tray, zone 1 is directly above it, and zone 2 extends 600mm beyond that.
  • Fittings in zone 1 and zone 2 need at least IPX4. Anything in zone 0 needs IPX7 and a safe extra-low voltage supply of no more than 12V AC.
  • New lighting or alterations in the zones around a bath or shower are notifiable under Part P, so use a registered electrician.
  • Every circuit in a bathroom should have 30mA RCD protection.
White marble shower room fitted by Vantage
A marble shower room we designed and fitted.

Start with layers, not a single ceiling light

A single light in the middle of the ceiling is the most common bathroom lighting mistake. It lights the floor well and your face badly, casting shadows under the eyes exactly where you need to see. Layered lighting fixes that, and makes the room feel larger and more comfortable. It is one of the first things we plan in any bathroom renovation.

1. General (ambient) light

This is the light that fills the room. In most bathrooms that means recessed downlights or one or two flush ceiling fittings. Space downlights so the light overlaps evenly rather than making bright pools, and do not put one directly above where you stand at the mirror. In a small bathroom, two or three well-placed fittings are often enough.

2. Task light at the mirror

The mirror is where you need the best light. Options include:

  • Illuminated mirrors or mirror cabinets with built-in lighting around the edge, which give even light across the face.
  • Wall lights either side of the mirror at roughly face height, which remove shadows better than a single light above.
  • A light bar above the mirror, which works well when it is wide enough to reach beyond both sides of the face.

3. Accent and mood light

This layer is what makes a bathroom feel finished. Popular ideas include:

  • LED strip lighting in a shower niche or recessed shelf.
  • Lighting under a wall-hung vanity or toilet, which makes the floor appear to float and doubles as a night light.
  • Lighting behind a mirror for a soft glow on the wall.
  • Low-level lights in the floor or wall along a walkway.
  • A statement pendant or chandelier, only where the zones allow it, usually well away from the bath and shower.

4. Night lighting

A low, warm light on a sensor or separate switch lets people use the bathroom at night without switching on the bright main lights. Under-vanity strips are ideal for this.

Colour, brightness and control

  • Colour temperature. Warm white feels relaxing in the evening. A cooler, neutral white at the mirror shows colours more accurately. Keep all the fittings in one layer the same colour temperature so the room does not look patchy.
  • Colour rendering. LED fittings list a colour rendering index (CRI). A higher CRI shows skin tones more naturally, which matters most at the mirror.
  • Dimming. Put the main lights on a dimmer so the same room works for a quick shower in the morning and a long bath at night. Check the fittings and drivers are compatible with the dimmer you choose.
  • Separate circuits for layers. Wire each layer so it can be switched on its own. It costs little extra at first fix and a lot to add later.
  • Switching. A standard wall switch must be outside the zones. That is why most bathrooms use a ceiling pull cord inside the room or a switch outside the door.

Bathroom safety zones and IP ratings

Water and electricity are a dangerous mix, so the wiring regulations (BS 7671) divide a bathroom into zones based on how likely each area is to get wet.

ZoneWhere it isMinimum protectionWhat can go there
Zone 0Inside the bath or shower tray, where water can collectIPX7 (protected against immersion)Only fittings designed for it, supplied at safe extra-low voltage of no more than 12V AC
Zone 1Directly above the bath or shower tray, up to 2.25m from the floor or the highest fixed shower head if that is higherAt least IPX4 (splash proof)Suitable fixed lights and equipment, with specific limits on voltage and protection
Zone 2600mm beyond the edge of zone 1, up to 2.25m from the floorAt least IPX4Suitable light fittings, shaver supply units and extractor fans
Outside the zonesThe rest of the roomNo zone requirement, though IP44 is a sensible minimum anywhere steam gathersMost fittings, still on an RCD-protected circuit

In a wet room without a tray, zone 1 is measured as a distance around the fixed shower head rather than the edge of a tray, so a wider area of the room counts. Always check where the water will actually reach.

What IP ratings mean

An IP rating has two digits. The first is protection against solid objects and dust, and the second is protection against water. An X means the first digit has not been tested. IPX4 means protected against splashing water from any direction. IP44 adds protection against small solid objects. IP65 means dust tight and protected against water jets, and is often chosen for shower downlights. IPX7 means protected against temporary immersion.

Bathroom electrics are not a DIY job

  • Adding or altering lighting in zones 0, 1 or 2 is notifiable under Part P of the Building Regulations. Use a registered electrician who can certify the work, or notify building control before you start.
  • Never fit an ordinary indoor light fitting in a shower area, even if it is high up.
  • Do not use a portable lamp or plug-in light strip in a bathroom.
  • If lights flicker, trip the circuit or show signs of water inside the fitting, switch off at the consumer unit and get the circuit checked.

Practical lighting ideas by bathroom type

Small bathrooms

Keep the ceiling clean with a few recessed downlights, use an illuminated mirror cabinet for task light and storage in one, and add an under-vanity strip to make the floor look larger.

Family bathrooms

Choose robust, easy to clean fittings, a bright main light for bath time, and a separate night light so children do not switch everything on at 3am.

En suites

A dimmable main light and a soft night light stop the en suite lighting up the bedroom. Consider a sensor light at low level.

Wet rooms and walk-in showers

Use shower-rated downlights and an LED niche for a clean look, and plan cable routes before tanking, so nothing has to pierce the waterproofing later. See our wet rooms page for how the floor and walls are built.

Plan the lighting before the walls are closed

Lighting is much easier to get right as part of a full bathroom renovation, because the cables, drivers for LED strips and any wall lights need to be in place before boarding, tanking and tiling. Decide where the mirror, vanity and shower niche will go first, then plan the lights around them. Remember to allow access to LED drivers, which may need replacing in future.

If you are only changing fittings in an existing bathroom, an electrician can often reuse existing points, but work in the zones is still notifiable. If your wiring is older, an EICR electrical safety check will show whether the circuits and RCD protection are up to current standards before new lighting goes in.

How we price it

Installations are quoted as a fixed price after a free survey, so the price you agree is the price you pay. That includes lighting and electrical work planned as part of a new bathroom. Smaller electrical jobs and repairs are charged at our published rates, all shown on our prices page. Our bathrooms carry a 12 month guarantee, and other work a 12 month labour guarantee.

Frequently asked questions

What IP rating do I need for bathroom lights?

Fittings in zone 1 and zone 2 need at least IPX4. Zone 0, inside the bath or shower tray, needs IPX7 and a safe extra-low voltage supply. Outside the zones there is no set rating, but IP44 is a sensible choice anywhere steam collects.

Can I have a pendant light or chandelier in a bathroom?

Yes, as long as it is outside the zones and rated for the room. In practice that usually means over the middle of a larger room or above a freestanding bath only if the height and zones allow, so check with your electrician first.

What is the best lighting for a bathroom mirror?

Light from both sides of the face, or an illuminated mirror that lights evenly around the edge, gives the fewest shadows. A single downlight directly above the mirror is the least flattering option.

Do I need an electrician to change a bathroom light?

Replacing a light fitting like for like outside the zones is simpler, but any new or altered lighting in zones 0, 1 or 2 is notifiable under Part P. For safety and certification, use a registered electrician.

Can LED strip lights go in a shower?

Yes, if they are rated for the zone, usually a sealed strip with a high IP rating, and the driver is fitted outside the zones where it can be reached. The cable route needs planning before the waterproofing goes on.

Bathroom lighting and electrics across Hertfordshire

We plan lighting as part of every bathroom we design and install, and carry out electrical work in bathrooms to the current regulations. To talk through your ideas, see our electrical installations page or our bathroom pages, or call 01462 506374.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.