To clear an airlock in central heating, switch the heating off and let the system cool, bleed each radiator in turn until water comes out instead of air, then top the boiler pressure back up to the level in your user guide and run the heating again. If radiators stay cold, the pump or boiler is noisy, or the air keeps coming back, the air is trapped where you cannot safely reach it or something is letting it in, and that needs a heating engineer.

In short

  • Signs of an airlock: cold radiators or cold tops, gurgling or tapping noises, and pressure that drops after bleeding.
  • Most airlocks clear by bleeding radiators and repressurising a sealed system with the filling loop.
  • On older open-vented systems, check the small feed and expansion tank in the loft has water in it.
  • Air that keeps returning points to a leak, a faulty air vent, a pump problem or corrosion inside the system.
  • Never open the boiler casing or try to free the pump inside a combi yourself.

What an airlock is

Central heating works by pumping water from the boiler around the radiators and back. Air is lighter than water, so any air in the system collects at the high points: the tops of radiators, loops of pipe that rise over doorways, the pump and parts of the boiler. A small pocket in a radiator just leaves a cold top. A bigger pocket in a pipe, pump or boiler can stop water moving through a whole circuit, which is a true airlock.

Air usually gets in when the system has been drained and refilled, for example after a new radiator or boiler, but it can also be drawn in or created inside a system that has a fault. Most airlocks can be cleared at home, and the ones that cannot are a routine job for our central heating repairs engineers.

Signs you have an airlock

  • Radiators that stay cold, or are cold at the top and warm at the bottom.
  • Upstairs radiators cold while downstairs ones are hot.
  • Gurgling, trickling or tapping noises from pipes and radiators.
  • A boiler that fires up then shuts down, or a pump that sounds noisy or rattly.
  • Boiler pressure that drops after you bleed the radiators.
  • Radiators that need bleeding again within a few weeks.

A radiator that is cold at the bottom but warm at the top is a different problem, usually sludge. Our guide to a radiator not heating up covers that.

Check these first

  1. Turn the heating off and wait until the radiators are cool. Hot water can scald, and a hot system is under more pressure.
  2. Check your system type. If your boiler has a pressure gauge on the front or underneath, it is a sealed system. If there is a small tank in the loft as well as a larger cold water tank, it is an open-vented system.
  3. Sealed system: note the pressure on the gauge. Most boilers want about 1 to 1.5 bar when cold, but check your user guide.
  4. Open-vented system: check the small feed and expansion tank in the loft has water in it and the float valve moves freely. If it is empty or stuck, air can be drawn into the system.
  5. Check the radiator valves are open on any cold radiator.
  6. Check the thermostat and timer are calling for heat, so you know the boiler and pump should be running.

How to clear an airlock step by step

Bleed the radiators

  1. Put a cloth or small bowl under the bleed valve at the top corner of the radiator.
  2. Fit the radiator key and turn it slowly anti-clockwise, a quarter to half a turn. You will hear air hissing out.
  3. When water starts to come out steadily, close the valve.
  4. Work around the house. A practical order is downstairs first, then upstairs, because air rises and gathers in the higher radiators.
  5. Pay extra attention to radiators at the end of long runs and any that were cold.

Our step-by-step guide on how to bleed a radiator has more detail, including what to do if the bleed valve is stuck.

Repressurise the boiler

Bleeding lets out air, and on a sealed system that lowers the pressure. If the gauge has dropped below the level in your user guide:

  1. Find the filling loop, usually a braided hose or built-in key under the boiler.
  2. Following your boiler’s user guide, open the valves slowly and watch the gauge.
  3. Close them when the pressure reaches the recommended cold level.
  4. If you overshoot, bleed a radiator a little to bring it back down.

Open-vented systems top up automatically from the loft tank, so there is no gauge to adjust.

Run the heating and check again

Switch the heating back on for 15 to 20 minutes, then feel each radiator. Air is sometimes pushed around the system and settles in a different radiator, so it is normal to need a second round of bleeding. Check the pressure again once the system has cooled.

What not to do

  • Do not open the boiler casing, remove covers or try to free a pump or air vent inside the boiler. Only a Gas Safe registered engineer may work on a gas appliance.
  • Do not overfill a sealed system. Too much pressure can make the safety valve discharge water outside.
  • Do not bleed radiators with the heating on. The water is hot and the system is under more pressure.
  • If radiators need bleeding every few weeks, the gas may come from corrosion inside the system rather than air, and it can be flammable. Keep naked flames away from the bleed valve and get the system checked.
  • If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows and do not use electrical switches.

Why air keeps coming back

If you have to bleed the same radiators every few weeks, there is a cause behind it.

CauseWhat you might noticeCan you fix it yourself?What the engineer does
Small leak on a sealed systemPressure keeps dropping, damp patches, drips at valvesYou can look for drips, but not repair inside the boilerFinds and repairs the leak, checks the expansion vessel and safety valve
Corrosion inside the systemFrequent bleeding, dark water from bleed valves, cold spotsNoTests the water, cleans the system and adds inhibitor
Failed automatic air ventAir never clears from the boiler or pump areaNoReplaces the air vent
Pump problem or airlocked pumpBoiler fires then stops, noisy pump, no circulationNoFrees or bleeds the pump, checks speed and position
Open-vented system pumping over or drawing airWater splashing into the loft tank, gurgling, frequent airNoChecks pump position, vent and feed pipework, and fixes the design fault
Pipework high pointsOne radiator or circuit always airlocksNoAdds or relocates an air vent, or changes the pipe route

Corrosion is worth taking seriously. When steel radiators corrode inside, they produce gas and black sludge that blocks radiators and damages pumps and boilers. A chemical clean or power flushing followed by fresh inhibitor usually solves it. Our article on power flushing and the signs your radiators need it explains when that is worthwhile.

If the pressure keeps falling after you have cleared the air, read our guide to a boiler that keeps losing pressure.

Airlocks in hot water pipes

Taps that splutter or deliver no water after the mains has been off can also have an airlock, but this is in the water supply rather than the heating. A common approach is to turn off the stopcock, open the taps to drain them, then close them partly, turn the stopcock back on and open the taps gradually so the flow pushes the air out. Take care with unvented cylinders and combi boilers, and if water still will not flow, call a plumber rather than forcing valves.

What an engineer will check

  • System pressure, the expansion vessel charge and the pressure relief valve.
  • The boiler’s automatic air vent and the pump, including bleeding the pump where the design allows.
  • Radiators, valves and pipework for leaks, and the water quality for signs of corrosion.
  • On open-vented systems, the feed and expansion tank, the vent pipe and the pump position.
  • Whether the system needs cleaning, inhibitor or a magnetic filter.

Our engineers are Gas Safe registered (956889) for any work on the boiler, and our labour carries a 12 month guarantee.

What we charge to fix it

Our prices, before you ring

Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee£150 + VAT
£180 inc VAT
Evenings and weekends, first hour including the call-out£297.60
inc VAT
Overnight, first hour including the call-out£330
inc VAT
If a new boiler is the better answer, fittedfrom £2,780
inc VAT

The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.

Frequently asked questions

Will an airlock in central heating clear itself?

Small amounts of air often work their way to a radiator or the boiler’s automatic air vent and can then be bled out. A true airlock that stops circulation rarely clears on its own and needs bleeding, repressurising or an engineer to clear the pump or pipework.

Can an airlock stop my boiler working?

Yes. If air collects in the pump or the boiler’s heat exchanger, water cannot circulate and the boiler may overheat and lock out. Try bleeding the radiators and checking the pressure first, and call an engineer if it will not restart.

Why is only my upstairs heating cold?

Air rises, so upstairs radiators are the first to fill with it. Bleed them, top up the pressure on a sealed system and check the loft tank on an open-vented one. If upstairs stays cold, the pump or a zone valve may be at fault.

How do I know if my central heating has air in it?

Gurgling noises, radiators cold at the top, and air hissing from the bleed valve are the classic signs. On a sealed system you may also see the pressure fall after bleeding.

Can I clear an airlock in a combi boiler myself?

You can bleed the radiators and repressurise using the filling loop if your user guide allows it. Air trapped inside the boiler or pump needs a Gas Safe registered engineer, because it means working inside the casing.

When to call an engineer

If you have bled every radiator and topped up the pressure but radiators are still cold, the pump is noisy, the pressure keeps falling or you are bleeding the system every few weeks, book a heating engineer. See our central heating repairs page or call 01462 506374. The phone is answered 24 hours a day, 7 days a week, with 24/7 emergency cover.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.