Baxi Boiler Fault Codes: What Each Error Code Means
Hertfordshire, Bedfordshire & Cambridgeshire
A Baxi fault code tells you why the boiler has stopped or is warning you, and the meaning depends on which Baxi you have: the current 200, 400, 600 and 800 models use codes such as E.04.10 or H.02.07, while older Duo-tec, EcoBlue, Platinum and Assure boilers use codes such as E133 or E118. Many codes are caused by things you can check safely yourself, such as low pressure, a frozen condensate pipe or a problem with the gas supply, but anything inside the boiler needs a Gas Safe registered engineer.
In short
- Newer Baxi boilers show a letter and four digits. Older Baxi boilers show E followed by two or three digits.
- The codes we see most are ignition and flame faults, low water pressure, circulation faults and frozen condensate.
- You can safely check the gas supply, the pressure gauge, the condensate pipe, the power and the controls.
- Reset only as your user guide describes, once or twice. A code that keeps returning needs an engineer.
- Never remove the boiler casing. Everything inside it is a job for a Gas Safe registered engineer.
Which type of Baxi fault code do you have?
Baxi uses two main code systems, and the same number can mean different things on different boilers, so start by working out which one yours uses.
Newer boilers: letter plus four digits. Baxi’s current Combi 2 and System 2 boilers (the 200, 400, 600 and 800, plus the Assure 500) show codes such as A.02.06, H.01.18 or E.04.10. As a rough guide from Baxi’s list, A codes are warnings, many H codes describe a stoppage the boiler can recover from once the cause clears, and E codes are lockouts that stop the boiler until the cause is fixed and it is reset.
Older boilers: E plus two or three digits. The Platinum, Duo-tec Compact, MainEco Compact, EcoBlue, Assure and several Potterton models show codes such as E133, E118 or E160. On some of these the display alternates between two parts of the code, for example E1 and 33 for E133.
Some older models use their own codes. For example, low pressure shows as E119 on the Duo-tec Combi HE A, the Platinum Combi HE and some Potterton boilers, but as E118 on later ranges.
If you are not sure, the model name is on the front of the boiler or on the data badge, usually visible when you lower the front flap. Our engineers can also confirm it on a boiler repair visit.
Newer Baxi fault codes (200, 400, 600 and 800)
These are the codes from Baxi’s own list for the Combi 2 and System 2 range that homeowners report most often.
| Code | What Baxi says it means | What it usually points to |
|---|---|---|
| A.02.06 | Low system pressure in the heating circuit | Pressure needs topping up |
| H.02.07 | Low pressure in the heating circuit (permanent) | Pressure too low to run, or a leak |
| E.02.39 | Minimum pressure not reached after 6 minutes of automatic filling | On boilers with auto fill, a leak or a filling problem |
| H.01.18 | No water circulation (temporary) | Air, low pressure, a closed valve or a pump issue |
| E.01.17 | No water circulation (permanent) | As above, but the boiler has locked out |
| E.04.10 | Burner failed to ignite after 4 attempts | Gas supply, frozen condensate, flue or ignition parts |
| E.04.12 | Ignition failure, flame monitoring | Flame not detected, often electrode or gas related |
| H.03.02 | Temporary flame loss | The flame dropped out, often gas or condensate related |
| E.01.04 | Flame loss detected five times in 24 hours | A recurring flame problem that needs investigating |
| E.04.13 | Fan impeller blocked or maximum speed exceeded | Fan or flue problem |
| E.01.20 | Maximum flue gas temperature reached | Overheating on the flue side, needs an engineer |
| H.00.81 | Room unit disconnected | A control or thermostat communication problem |
| H.03.05 | Power supply voltage too low | An electrical supply problem |
Our guide to the Baxi E.04.10 fault code goes through the most common lockout on this range step by step.
Older Baxi fault codes
These codes appear on Baxi’s list for the Platinum, Duo-tec Compact, MainEco Compact, Megaflo Compact, EcoBlue and Assure ranges.
| Code | What Baxi says it means |
|---|---|
| E09 | Gas valve connection fault |
| E10 | External probe (outdoor sensor) fault |
| E20 | Central heating NTC sensor fault, short or open circuit |
| E28 | Flue NTC sensor fault, short or open circuit |
| E110 | Boiler maximum temperature exceeded (probable pump jammed or air in the circuit), or safety thermostat tripped |
| E118 | Water pressure low, below 0.5 bar |
| E125 | Water circulation fault |
| E128 | Safety error for frequent loss of flame |
| E130 | Flue thermostat sensor tripped (lockout) |
| E133 | Gas supply fault: check the power supply, sensing electrode, spark electrode and cable |
| E160 | Fan fault |
| E83 to E87 | No communication |
The ones we are called to most often are E133, E118 or E119 and E125. Our guides to Baxi E133, Baxi and Potterton E119 and Baxi E125 cover each one in detail.
Check these first
Whatever code you have, these checks are safe for a homeowner and clear a surprising number of breakdowns.
- Check the gas supply. Is the hob working? If you have a prepayment meter, does it have credit? If other gas appliances are off too, the problem is the supply, not the boiler.
- Check the pressure gauge. Most systems should read about 1 to 1.5 bar when cold. If it is low, top it up with the filling link or loop exactly as your Baxi user guide shows. Many current Baxi boilers have a green EasyFill link under the gauge.
- Check the condensate pipe in cold weather. Baxi says a frozen condensate pipe usually shows as E133 or E28 on most of its boilers. Thaw the outside section with warm, not boiling, water, then reset.
- Check the power. Make sure the fused spur is on and the fuse has not blown, and that there has been no power cut.
- Check the controls. Make sure the thermostat is calling for heat and the timer is set to on.
- Reset the boiler once or twice. Baxi’s guide describes three methods depending on the model: a reset button, turning the temperature knob fully anticlockwise until the lockout light goes out, or holding the selector on R for at least five seconds. Follow the method in your user guide.
If the code clears and the boiler runs normally, keep an eye on it. If it returns, stop resetting and book an engineer.
What not to do
- Do not remove the boiler casing or touch anything inside it. Under the Gas Safety (Installation and Use) Regulations 1998, only a Gas Safe registered engineer may work on a gas appliance.
- Do not keep resetting. Baxi says frequent lockouts indicate a fault. Each reset on an ignition fault sends gas to a burner that has already failed to light.
- Do not use boiling water on a frozen condensate pipe. It can crack the plastic and scald you.
- Do not overfill the system. Too much pressure makes the relief valve discharge.
- If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows, do not use electrical switches, and turn the gas off at the meter if it is safe to do so.
Common causes behind Baxi fault codes
| Cause | What you might notice | Can you fix it yourself? | What the engineer does |
|---|---|---|---|
| Low system pressure | Gauge below 1 bar, E118, E119, A.02.06 or H.02.07 | Often, by topping up | Finds the leak, checks the expansion vessel and relief valve |
| Frozen condensate pipe | E133 or E28 in freezing weather, gurgling | Yes, with warm water | Reroutes or insulates the pipe so it does not freeze again |
| Gas supply problem | Hob also off, prepay meter empty | Sometimes | Checks the meter, pressure and gas valve |
| Worn ignition or flame sensing electrode | Ignition codes that come and go | No | Inspects and replaces the electrode |
| Air or sludge in the system | Circulation codes, noisy boiler, cold radiators | Bleeding radiators may help | Checks the pump, cleans the system and fits a filter |
| Failed sensor or fan | Sensor or fan codes that return after a reset | No | Tests and replaces the part |
| Control or power fault | Communication or voltage codes | Check the fused spur and controls | Tests wiring and the circuit board |
When a code points to a bigger problem
Some codes are nearly always a job for an engineer: fan faults, flue temperature faults, gas valve faults, sensor faults and any code that keeps coming back after a reset. The engineer will check the gas pressure at the boiler, the flue, the condensate trap, the electrodes, the fan and the sensors, and then look at the history of codes to see whether one part is wearing out.
Circulation and pressure codes that keep returning are also worth taking seriously. A system that keeps losing pressure has a leak somewhere, and a system full of sludge wears out pumps and heat exchangers. Cleaning the system and fitting a magnetic filter often stops the same codes returning.
Repair or replace?
Most Baxi fault codes are fixed with a single part or a straightforward repair, and a code on its own is rarely a reason to replace a boiler. It is worth thinking about replacement if the boiler is old, the heat exchanger is failing, parts are getting hard to find, or several faults are building up at once. We will give you an honest view of both options.
What we charge to fix it
Our prices, before you ring
| Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee | £150 + VAT £180 inc VAT |
| Evenings and weekends, first hour including the call-out | £297.60 inc VAT |
| Overnight, first hour including the call-out | £330 inc VAT |
| If a new boiler is the better answer, fitted | from £2,780 inc VAT |
The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.
Frequently asked questions
How do I reset a Baxi boiler?
It depends on the model. Baxi describes three methods: pressing a reset button, turning the temperature knob fully anticlockwise until the lockout light goes out, or turning the selector to R and holding it for at least five seconds. Your user guide shows which applies to your boiler.
Why does my Baxi boiler show E1 and 33?
On older Baxi boilers the display alternates between two parts of the code, so E1 and 33 means E133. Baxi links it to the gas supply, ignition or flame, or a blocked condensate pipe.
What is the low pressure code on a Baxi boiler?
On newer Baxi boilers it is A.02.06 as a warning and H.02.07 when the pressure is too low to run. On many older Baxi boilers it is E118, and on some older models and Potterton boilers it is E119.
Can a frozen condensate pipe cause a Baxi fault code?
Yes. Baxi says a frozen condensate pipe usually shows as E133 or E28 on most of its boilers. Thaw the outside section with warm water and reset the boiler.
Is it safe to keep using a Baxi boiler that shows a fault code?
A warning such as a low pressure alert is not dangerous in itself, but a boiler that has locked out should not be repeatedly reset. If a code keeps returning, leave the boiler off and book a Gas Safe registered engineer.
When to call an engineer
If the checks above do not clear the code, or it keeps coming back, it needs a Gas Safe registered engineer. We repair and service Baxi and Potterton boilers across Hertfordshire, Bedfordshire and Cambridgeshire, our phone is answered 24 hours a day with 24/7 emergency cover, and we are Gas Safe registered (956889). Book a boiler repair or call 01462 506374.
What our customers say
Rather have an engineer look at it?
Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374