Skip to main content

Vantage Plumbing and Heating

Baxi Boiler Fault Codes: What Each Error Code Means

Hertfordshire, Bedfordshire & Cambridgeshire

Fully Stocked Vans12 Month Labour GuaranteeGas Safe Registered 956889

A Baxi fault code tells you why the boiler has stopped or is warning you, and the meaning depends on which Baxi you have: the current 200, 400, 600 and 800 models use codes such as E.04.10 or H.02.07, while older Duo-tec, EcoBlue, Platinum and Assure boilers use codes such as E133 or E118. Many codes are caused by things you can check safely yourself, such as low pressure, a frozen condensate pipe or a problem with the gas supply, but anything inside the boiler needs a Gas Safe registered engineer.

In short

  • Newer Baxi boilers show a letter and four digits. Older Baxi boilers show E followed by two or three digits.
  • The codes we see most are ignition and flame faults, low water pressure, circulation faults and frozen condensate.
  • You can safely check the gas supply, the pressure gauge, the condensate pipe, the power and the controls.
  • Reset only as your user guide describes, once or twice. A code that keeps returning needs an engineer.
  • Never remove the boiler casing. Everything inside it is a job for a Gas Safe registered engineer.

Which type of Baxi fault code do you have?

Baxi uses two main code systems, and the same number can mean different things on different boilers, so start by working out which one yours uses.

Newer boilers: letter plus four digits. Baxi’s current Combi 2 and System 2 boilers (the 200, 400, 600 and 800, plus the Assure 500) show codes such as A.02.06, H.01.18 or E.04.10. As a rough guide from Baxi’s list, A codes are warnings, many H codes describe a stoppage the boiler can recover from once the cause clears, and E codes are lockouts that stop the boiler until the cause is fixed and it is reset.

Older boilers: E plus two or three digits. The Platinum, Duo-tec Compact, MainEco Compact, EcoBlue, Assure and several Potterton models show codes such as E133, E118 or E160. On some of these the display alternates between two parts of the code, for example E1 and 33 for E133.

Some older models use their own codes. For example, low pressure shows as E119 on the Duo-tec Combi HE A, the Platinum Combi HE and some Potterton boilers, but as E118 on later ranges.

If you are not sure, the model name is on the front of the boiler or on the data badge, usually visible when you lower the front flap. Our engineers can also confirm it on a boiler repair visit.

Newer Baxi fault codes (200, 400, 600 and 800)

These are the codes from Baxi’s own list for the Combi 2 and System 2 range that homeowners report most often.

CodeWhat Baxi says it meansWhat it usually points to
A.02.06Low system pressure in the heating circuitPressure needs topping up
H.02.07Low pressure in the heating circuit (permanent)Pressure too low to run, or a leak
E.02.39Minimum pressure not reached after 6 minutes of automatic fillingOn boilers with auto fill, a leak or a filling problem
H.01.18No water circulation (temporary)Air, low pressure, a closed valve or a pump issue
E.01.17No water circulation (permanent)As above, but the boiler has locked out
E.04.10Burner failed to ignite after 4 attemptsGas supply, frozen condensate, flue or ignition parts
E.04.12Ignition failure, flame monitoringFlame not detected, often electrode or gas related
H.03.02Temporary flame lossThe flame dropped out, often gas or condensate related
E.01.04Flame loss detected five times in 24 hoursA recurring flame problem that needs investigating
E.04.13Fan impeller blocked or maximum speed exceededFan or flue problem
E.01.20Maximum flue gas temperature reachedOverheating on the flue side, needs an engineer
H.00.81Room unit disconnectedA control or thermostat communication problem
H.03.05Power supply voltage too lowAn electrical supply problem

Our guide to the Baxi E.04.10 fault code goes through the most common lockout on this range step by step.

Older Baxi fault codes

These codes appear on Baxi’s list for the Platinum, Duo-tec Compact, MainEco Compact, Megaflo Compact, EcoBlue and Assure ranges.

CodeWhat Baxi says it means
E09Gas valve connection fault
E10External probe (outdoor sensor) fault
E20Central heating NTC sensor fault, short or open circuit
E28Flue NTC sensor fault, short or open circuit
E110Boiler maximum temperature exceeded (probable pump jammed or air in the circuit), or safety thermostat tripped
E118Water pressure low, below 0.5 bar
E125Water circulation fault
E128Safety error for frequent loss of flame
E130Flue thermostat sensor tripped (lockout)
E133Gas supply fault: check the power supply, sensing electrode, spark electrode and cable
E160Fan fault
E83 to E87No communication

The ones we are called to most often are E133, E118 or E119 and E125. Our guides to Baxi E133, Baxi and Potterton E119 and Baxi E125 cover each one in detail.

Check these first

Whatever code you have, these checks are safe for a homeowner and clear a surprising number of breakdowns.

  1. Check the gas supply. Is the hob working? If you have a prepayment meter, does it have credit? If other gas appliances are off too, the problem is the supply, not the boiler.
  2. Check the pressure gauge. Most systems should read about 1 to 1.5 bar when cold. If it is low, top it up with the filling link or loop exactly as your Baxi user guide shows. Many current Baxi boilers have a green EasyFill link under the gauge.
  3. Check the condensate pipe in cold weather. Baxi says a frozen condensate pipe usually shows as E133 or E28 on most of its boilers. Thaw the outside section with warm, not boiling, water, then reset.
  4. Check the power. Make sure the fused spur is on and the fuse has not blown, and that there has been no power cut.
  5. Check the controls. Make sure the thermostat is calling for heat and the timer is set to on.
  6. Reset the boiler once or twice. Baxi’s guide describes three methods depending on the model: a reset button, turning the temperature knob fully anticlockwise until the lockout light goes out, or holding the selector on R for at least five seconds. Follow the method in your user guide.

If the code clears and the boiler runs normally, keep an eye on it. If it returns, stop resetting and book an engineer.

What not to do

  • Do not remove the boiler casing or touch anything inside it. Under the Gas Safety (Installation and Use) Regulations 1998, only a Gas Safe registered engineer may work on a gas appliance.
  • Do not keep resetting. Baxi says frequent lockouts indicate a fault. Each reset on an ignition fault sends gas to a burner that has already failed to light.
  • Do not use boiling water on a frozen condensate pipe. It can crack the plastic and scald you.
  • Do not overfill the system. Too much pressure makes the relief valve discharge.
  • If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows, do not use electrical switches, and turn the gas off at the meter if it is safe to do so.

Common causes behind Baxi fault codes

CauseWhat you might noticeCan you fix it yourself?What the engineer does
Low system pressureGauge below 1 bar, E118, E119, A.02.06 or H.02.07Often, by topping upFinds the leak, checks the expansion vessel and relief valve
Frozen condensate pipeE133 or E28 in freezing weather, gurglingYes, with warm waterReroutes or insulates the pipe so it does not freeze again
Gas supply problemHob also off, prepay meter emptySometimesChecks the meter, pressure and gas valve
Worn ignition or flame sensing electrodeIgnition codes that come and goNoInspects and replaces the electrode
Air or sludge in the systemCirculation codes, noisy boiler, cold radiatorsBleeding radiators may helpChecks the pump, cleans the system and fits a filter
Failed sensor or fanSensor or fan codes that return after a resetNoTests and replaces the part
Control or power faultCommunication or voltage codesCheck the fused spur and controlsTests wiring and the circuit board

When a code points to a bigger problem

Some codes are nearly always a job for an engineer: fan faults, flue temperature faults, gas valve faults, sensor faults and any code that keeps coming back after a reset. The engineer will check the gas pressure at the boiler, the flue, the condensate trap, the electrodes, the fan and the sensors, and then look at the history of codes to see whether one part is wearing out.

Circulation and pressure codes that keep returning are also worth taking seriously. A system that keeps losing pressure has a leak somewhere, and a system full of sludge wears out pumps and heat exchangers. Cleaning the system and fitting a magnetic filter often stops the same codes returning.

Repair or replace?

Most Baxi fault codes are fixed with a single part or a straightforward repair, and a code on its own is rarely a reason to replace a boiler. It is worth thinking about replacement if the boiler is old, the heat exchanger is failing, parts are getting hard to find, or several faults are building up at once. We will give you an honest view of both options.

What we charge to fix it

Our prices, before you ring

Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee£150 + VAT
£180 inc VAT
Evenings and weekends, first hour including the call-out£297.60
inc VAT
Overnight, first hour including the call-out£330
inc VAT
If a new boiler is the better answer, fittedfrom £2,780
inc VAT

The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.

Frequently asked questions

How do I reset a Baxi boiler?

It depends on the model. Baxi describes three methods: pressing a reset button, turning the temperature knob fully anticlockwise until the lockout light goes out, or turning the selector to R and holding it for at least five seconds. Your user guide shows which applies to your boiler.

Why does my Baxi boiler show E1 and 33?

On older Baxi boilers the display alternates between two parts of the code, so E1 and 33 means E133. Baxi links it to the gas supply, ignition or flame, or a blocked condensate pipe.

What is the low pressure code on a Baxi boiler?

On newer Baxi boilers it is A.02.06 as a warning and H.02.07 when the pressure is too low to run. On many older Baxi boilers it is E118, and on some older models and Potterton boilers it is E119.

Can a frozen condensate pipe cause a Baxi fault code?

Yes. Baxi says a frozen condensate pipe usually shows as E133 or E28 on most of its boilers. Thaw the outside section with warm water and reset the boiler.

Is it safe to keep using a Baxi boiler that shows a fault code?

A warning such as a low pressure alert is not dangerous in itself, but a boiler that has locked out should not be repeatedly reset. If a code keeps returning, leave the boiler off and book a Gas Safe registered engineer.

When to call an engineer

If the checks above do not clear the code, or it keeps coming back, it needs a Gas Safe registered engineer. We repair and service Baxi and Potterton boilers across Hertfordshire, Bedfordshire and Cambridgeshire, our phone is answered 24 hours a day with 24/7 emergency cover, and we are Gas Safe registered (956889). Book a boiler repair or call 01462 506374.

What our customers say

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.