Boiler Pressure Too High: Causes and What to Do

Hertfordshire, Bedfordshire & Cambridgeshire

Fully Stocked Vans12 Month Labour GuaranteeGas Safe Registered 956889

If your boiler pressure is too high, the usual cause is too much water in the sealed heating system, either from a filling loop left open or from a faulty expansion vessel, and you can often bring it down safely by bleeding a radiator with the heating off. Most boilers should read about 1 to 1.5 bar when cold, so a gauge near or in the red zone around 3 bar needs attention, and if the pressure climbs again after you lower it, a Gas Safe registered engineer needs to find out why.

In short

  • Check the pressure with the heating off and the boiler cold. Around 1 to 1.5 bar is normal for most boilers.
  • Pressure rises a little when the system heats up. A rise of a few tenths of a bar is normal, a jump towards 3 bar is not.
  • The most common causes are an open or leaking filling loop, overfilling and a flat expansion vessel.
  • You can lower the pressure by closing the filling loop and bleeding a radiator, then rechecking the gauge.
  • If water is dripping from the small pipe outside, the pressure relief valve has opened and the fault needs an engineer.
Ideal boiler installed by Vantage in a fitted cupboard, with copper pipework and a magnetic system filter
One of our boiler installations: an Ideal combi in a fitted cupboard with a magnetic system filter.

What boiler pressure should be

Combi and system boilers work on a sealed system. The water in your radiators and pipes is kept under a little pressure so the pump can move it and the boiler can run safely. The gauge on the front of the boiler, or the reading on its display, shows that pressure in bar.

Manufacturers give slightly different figures, so your own user guide has the final word, but as a guide:

ReadingWhat it usually means
Below 1 bar (cold)Low. Many boilers will stop and show a fault at around 0.5 bar.
1 to 1.5 bar (cold)Normal for most homes.
Up to about 2 bar (hot)Normal. Pressure rises as the water expands when it heats up.
Above 2.5 barHigh. Ideal’s guidance treats anything over 2.75 bar as high pressure.
3 bar or in the red zoneThe pressure relief valve on most domestic sealed systems is set to open at 3 bar.

The key test is to compare the pressure cold and hot. Switch the heating off, let the boiler cool for an hour, and note the reading. Then run the heating for half an hour and look again. A small rise is expected. A big swing, for example from 1.5 bar cold to nearly 3 bar hot, points to the expansion vessel.

Is high boiler pressure dangerous?

Not usually in the short term. Your boiler has safety devices designed for exactly this: the pressure relief valve will open to let water out before the pressure becomes unsafe, and many boilers will lock out and show a fault. Still, you should not ignore it. Every time the relief valve opens it can let dirt settle on its seat, and it may not seal properly afterwards, which leads to a slow drip and then low pressure. A system that swings between high and low pressure is also taking in fresh water each time it is topped up, which speeds up corrosion inside radiators.

If your boiler shows high pressure and you are worried about it, turn the heating off and book a boiler repair visit. If you smell gas at any point, that is a different emergency: call the National Gas Emergency Service on 0800 111 999.

Why boiler pressure goes too high

The filling loop was left open or is letting by

The filling loop is the braided hose or built-in key with one or two valves, usually under the boiler, that connects the heating system to the mains water. It is only meant to be open while you top up. If it is left slightly open, mains pressure keeps pushing water in. Valves also wear, so a loop that looks closed can still let water pass slowly, and the pressure creeps up over days.

The system was overfilled

It is easy to overshoot when topping up, especially if you fill the system while it is hot or do not watch the gauge closely. The same thing can happen after radiators have been taken off for decorating and the system has been refilled.

The expansion vessel has lost its air charge

Water expands when it heats up. The expansion vessel, a small tank usually inside the boiler case, has a rubber diaphragm with air on one side to absorb that expansion. Over time the air charge leaks away, or the diaphragm fails. With nowhere for the extra volume to go, the pressure shoots up as the heating warms and drops back when it cools. This is one of the most common causes of both high and low pressure, and it is a job for an engineer.

A leak inside a combi’s plate heat exchanger

On a combi boiler, mains water and heating water pass each other inside the plate heat exchanger. If an internal leak develops, mains water at higher pressure can push into the heating side. The sign is pressure that rises when you run the hot taps, even with the filling loop closed.

A faulty gauge or pressure sensor

Now and then the reading is wrong rather than the pressure. An engineer can check the true pressure with a separate gauge.

Check these first

  1. Read the gauge cold. Switch the heating off and let the boiler cool before you judge the pressure.
  2. Check the filling loop. Make sure both valves are fully closed (usually a quarter turn so the lever sits across the pipe). If your loop is a removable braided hose, your user guide may say to disconnect it after use.
  3. Bleed a radiator to lower the pressure. With the heating off and the radiators cool, hold a cloth under the bleed valve and open it slowly with a radiator key. Let water out a little at a time while someone watches the gauge, and close the valve when it reads about 1 to 1.5 bar. Our guide on how to bleed a radiator walks through it.
  4. Recheck over the next day. If the pressure stays where you set it, the likely cause was overfilling. If it climbs again with the loop closed, there is a fault.
  5. Look outside for a dripping pipe. Most boilers have a small copper pipe, the pressure relief discharge, running to an outside wall. Water dripping from it means the relief valve has opened.

What not to do

  • Do not touch the pressure relief valve or try to open it by hand. It is a safety device and may not reseal.
  • Do not block, cap or cut the discharge pipe outside.
  • Do not remove the boiler casing to reach the expansion vessel. Under the Gas Safety (Installation and Use) Regulations 1998, only a Gas Safe registered engineer may work on a gas appliance.
  • Do not bleed radiators with the heating on. The water is hot and the pressure is at its highest.
  • If you smell gas, call 0800 111 999, open windows, do not use electrical switches, and turn the gas off at the meter if it is safe to do so.

Common causes at a glance

CauseWhat you might noticeCan you fix it yourself?What the engineer does
Filling loop left openPressure creeping up steadilyYes, close both valvesChecks the valves seal properly
Filling loop letting byPressure rises with the valves closedNoReplaces the filling loop valve
Overfilled systemHigh after topping up, stable once loweredYes, by bleeding a radiatorSets the correct cold pressure
Flat expansion vesselNormal cold, very high when hot, then dropsNoRecharges the vessel or replaces it
Combi plate heat exchanger leakPressure rises when hot taps runNoConfirms the leak and replaces the plate heat exchanger
Faulty relief valveDripping discharge pipe, pressure falls afterNoReplaces the valve and finds what made it open
Faulty gauge or sensorReading does not match a test gaugeNoReplaces the gauge or sensor

What an engineer will check

An engineer starts by confirming the real pressure, then works through the system in a logical order. They check the filling loop for leaks by isolating it, measure the air charge in the expansion vessel with the system drained down on the boiler side, and watch how the pressure behaves as the boiler heats. On a combi they check whether running hot water pushes the pressure up. If the relief valve has been discharging, they replace it rather than trusting it to reseal, and make sure the discharge pipe is safe.

If the pressure problem has been going on for a while and the system has been topped up often, they may also look at the water quality. Frequent refilling brings in fresh oxygen and, across most of Hertfordshire, hard water, both of which add to sludge and scale.

Repair or replace?

High pressure on its own is rarely a reason to replace a boiler. A filling loop valve, a relief valve or recharging an expansion vessel are all routine repairs. A failed plate heat exchanger or a replacement expansion vessel is a larger job, and on an old boiler with other faults it can tip the balance. Our repair or replace guide sets out how we help customers decide.

What we charge to fix it

Our prices, before you ring

Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee£150 + VAT
£180 inc VAT
Evenings and weekends, first hour including the call-out£297.60
inc VAT
Overnight, first hour including the call-out£330
inc VAT
If a new boiler is the better answer, fittedfrom £2,780
inc VAT

The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.

Frequently asked questions

What should my boiler pressure be when the heating is on?

It will read higher than when cold, commonly up to about 2 bar on most systems. Manufacturers such as Baxi describe 1 to 2 bar as the normal operating range. Check your own user guide, because figures differ slightly between models.

Can high boiler pressure cause a leak?

It can make the pressure relief valve open and discharge water through the pipe outside, and repeated high pressure puts extra strain on joints and valves. It is also often linked to the opposite problem, because once the relief valve has let water out the pressure then falls too low. Our guide to a boiler that keeps losing pressure explains that side of the cycle.

Why does my boiler pressure go up when the heating is on?

Water expands as it heats, so a small rise is normal. A large rise, towards 2.5 or 3 bar, usually means the expansion vessel has lost its air charge and can no longer absorb the extra volume.

Why does my boiler pressure rise when I use hot water?

On a combi, this usually points to an internal leak in the plate heat exchanger, letting mains water into the heating circuit. It needs a Gas Safe registered engineer to confirm and repair.

Should I turn my boiler off if the pressure is too high?

If the pressure is at or near 3 bar, or water is coming from the discharge pipe, switch the heating off, let it cool and lower the pressure by bleeding a radiator. If it rises again, leave it off and book an engineer.

When to call an engineer

If the pressure keeps rising with the filling loop closed, swings a long way between cold and hot, or the discharge pipe outside is dripping, it is time for a proper repair. We are Gas Safe registered (956889), our phones are answered 24 hours a day with 24/7 emergency cover, and our engineers carry the common parts on fully stocked vans. See our boiler repair page or call 01462 506374.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.