Central Heating Not Working: What to Check First
Hertfordshire, Bedfordshire & Cambridgeshire
If your central heating is not working, start with the simple things: check the boiler has power, that the thermostat is set above the room temperature, that the timer is calling for heat, and that the pressure gauge reads around 1 to 1.5 bar. Most winter heating failures come down to one of those, a fault code on the boiler, or a frozen condensate pipe, and anything beyond those checks is a job for a Gas Safe registered engineer.
In short
- Check power, thermostat, timer and boiler pressure before anything else.
- Look at the boiler display. A fault code tells you, and your engineer, where to start.
- In cold weather, a frozen condensate pipe is one of the most common causes of a boiler that will not light.
- If some radiators work and others do not, the boiler is usually fine and the problem is in the pipework or radiators.
- Never remove the boiler casing. Work inside the boiler is Gas Safe work by law.
- Smell gas? Call the National Gas Emergency Service on 0800 111 999.
First, work out what “not working” means
“The heating is not working” can mean several different faults, and each points somewhere different. Before you start checking things, notice which of these describes your home. If none of the checks below help, our central heating repairs team can find the fault.
| What you notice | What it usually points to | Where to start |
|---|---|---|
| No heating and no hot water | Boiler not running: power, gas, pressure, a lockout or a failed part | The boiler display and the checks below |
| Hot water works, heating does not | Controls, a diverter valve (combi) or a motorised zone valve (system or regular boiler) | Thermostat and timer first |
| Heating works, no hot water | Diverter valve, hot water settings or cylinder controls | Our guide to no hot water but the heating works |
| Some radiators cold, others hot | Air, a stuck valve, poor balancing or sludge | Bleed and check valves |
| Radiators cold at the bottom, warm at the top | Sludge settling in the radiator | Usually needs a cleanse or powerflush |
| Boiler fires up then cuts out | Low pressure, a circulation problem or a flame fault | Pressure gauge and display code |
| Heating will not turn off | Controls, a stuck zone valve or a wiring fault | Thermostat and programmer, then an engineer |
Check these first
These checks are all safe for a homeowner or tenant to do, and none of them involve opening the boiler.
- Is there power to the boiler? Look for lights or a display. If it is completely dead, check the fused spur (the switch near the boiler) is on, and look at your consumer unit for a tripped switch. If the fuse in the spur keeps blowing, stop and call an engineer.
- Check the thermostat. Turn it up a few degrees above the current room temperature. If it is a wireless or battery thermostat, replace the batteries. A thermostat in a warm hallway or next to a lamp can think the house is already warm.
- Check the timer or programmer. After a power cut, many timers lose the time or reset to off. Make sure the heating is set to on or to a timed period that covers now, and that no holiday or frost mode is active. If you have a smart thermostat, check the app has not lost its connection.
- Look at the boiler display. Write down or photograph any fault code before you do anything else. The code tells you what the boiler has detected.
- Check the pressure gauge. On most combi and system boilers the gauge should read about 1 to 1.5 bar with the heating cold. Below about 1 bar, many boilers will not run. If your boiler’s user guide shows how to top up with the filling loop, you can do this yourself. If you are topping up regularly, read our guide on a boiler that keeps losing pressure.
- Check the gas. Try a gas hob if you have one. If that will not light either, the problem is the supply, not the boiler. On a prepayment meter, check there is credit, including emergency credit.
- In freezing weather, check the condensate pipe. This is the plastic pipe that runs from a condensing boiler to a drain, often outside. If it freezes, the boiler locks out. Pour warm (not boiling) water over the frozen section, then reset the boiler. Our frozen condensate pipe guide shows how.
- Reset once or twice. If the boiler shows a lockout, use the reset button as your user guide describes. If the same code comes back, stop resetting. Repeated resets do not fix the cause and some boilers stop accepting resets after a few attempts.
What not to do
- Do not remove the boiler casing or touch anything inside it. Under the Gas Safety (Installation and Use) Regulations 1998, only a Gas Safe registered engineer may work on a gas appliance.
- Do not keep resetting a boiler that keeps locking out.
- Do not use boiling water on a condensate pipe, as it can crack the plastic.
- If you smell gas, open the windows, do not use electrical switches, turn off the gas at the meter if it is safe to do so, and call the National Gas Emergency Service on 0800 111 999.
If the boiler is running but the radiators are cold
When the boiler lights and the hot water is fine, but the house is not warming up, the fault is usually in the heating side of the system rather than the boiler itself.
Controls and valves
On a combi boiler, a single diverter valve inside the boiler sends hot water either to the taps or to the radiators. If it sticks in the hot water position, you get hot taps but cold radiators. That is an engineer’s job, because the valve is inside the case.
On a system or regular boiler with a hot water cylinder, a motorised zone valve (usually in the airing cupboard) opens to send water to the radiators when the thermostat calls for heat. If the valve motor or its switch fails, the heating side never opens. Many zone valves have a small manual lever, but forcing it is only a temporary test, and the wiring behind it should be left to an engineer.
One or two cold radiators
If most of the house is warm and a few radiators are cold:
- Cold at the top, warm at the bottom means trapped air. Our guide on how to bleed a radiator walks you through it. Check the boiler pressure afterwards, because bleeding lets some water out.
- Cold at the bottom, warm at the top usually means sludge. That needs a system clean, often a powerflush.
- Completely cold can be a closed valve, or a thermostatic radiator valve (TRV) with a stuck pin. The pin is under the head, and it can seize after a summer of not moving.
- Radiators furthest from the boiler are only lukewarm points to the system needing balancing, or a weak pump.
Our radiator not heating up guide covers each of these in more detail.
Common causes and who fixes them
| Cause | What you might notice | Can you fix it yourself? | What the engineer does |
|---|---|---|---|
| Thermostat or timer settings | No heating, but hot water works | Yes, check settings and batteries | Tests the controls and wiring if settings are correct |
| Low system pressure | Gauge below 1 bar, low pressure code | Yes, top up if your user guide allows | Finds the leak or faulty part if it keeps dropping |
| Frozen condensate pipe | Lockout in cold weather, gurgling | Yes, thaw with warm water | Reroutes, insulates or upsizes the pipe if it keeps freezing |
| Air in radiators | Cold at the top | Yes, bleed them | Checks for the cause of repeated air |
| Sludge | Cold at the bottom, noisy boiler | No | Cleans the system and fits or cleans a filter |
| Diverter or zone valve fault | Hot water only, or heating stuck | No | Tests and replaces the valve or motor |
| Pump failure | Boiler fires then overheats or locks out | No | Tests and replaces the pump |
| Ignition or flame fault | Lockout code, will not light | No | Checks ignition, flame sensing, gas and flue |
| Circuit board fault | Dead display, random behaviour | No | Diagnoses and replaces the board |
What an engineer will check
When you book a central heating repair, the engineer will start with the fault code and the boiler’s fault history, then check gas pressure and supply, the ignition and flame sensing, the fan and flue, the pump and circulation, the pressure sensor, and the valves and controls outside the boiler. On a system with a cylinder they will check the zone valves and wiring centre. If the fault is inside the boiler itself, it becomes a boiler repair, and our vans carry the common parts for the major brands.
Repair or replace?
Most heating faults are repairs: a valve, a pump, a sensor or a control. Replacement is worth talking about when the boiler is old and parts are getting hard to find, when you are facing a major part on an ageing boiler, or when the same faults keep coming back. We will tell you plainly which side of the line your boiler is on.
What we charge to fix it
Our prices, before you ring
| Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee | £150 + VAT £180 inc VAT |
| Evenings and weekends, first hour including the call-out | £297.60 inc VAT |
| Overnight, first hour including the call-out | £330 inc VAT |
| If a new boiler is the better answer, fitted | from £2,780 inc VAT |
The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.
Our repair work comes with a 12 month labour guarantee.
Frequently asked questions
Why is my central heating not coming on but I have hot water?
On a combi boiler, the usual causes are the thermostat or timer not calling for heat, or a diverter valve stuck in the hot water position. On a system or regular boiler, it is often a motorised zone valve that is not opening. Check the controls first, then book an engineer if they are set correctly.
Why has my heating stopped working after a power cut?
Many timers and programmers lose their settings when the power goes off, so the heating is simply switched off or on the wrong time. Some boilers also need a reset after a power cut. Check the clock and settings, then the boiler display.
Is it safe to reset my boiler?
Yes, pressing the reset button once or twice as described in your user guide is safe. If the same fault code comes back, stop, because the boiler is telling you something needs fixing. Some boilers block further resets after several attempts in a short time.
What pressure should my central heating be?
Most combi and system boilers should read around 1 to 1.5 bar when the heating is cold, rising a little when it is hot. Your boiler’s user guide gives the exact figure. If it keeps dropping below 1 bar, there is a leak or a faulty part.
Can a thermostat stop the heating working?
Yes. A thermostat with flat batteries, a lost wireless connection or a setting below the room temperature will not ask the boiler for heat, so the boiler sits idle even though nothing is wrong with it. This is one of the first things to check.
Do you offer emergency heating repairs?
Yes. Our phone is answered 24 hours a day, 7 days a week, and we offer 24/7 emergency cover for heating and boiler breakdowns.
Help in Hertfordshire, Bedfordshire and Cambridgeshire
If you have worked through the checks and the heating is still off, our Gas Safe registered engineers (registration 956889) can find the fault. Book a central heating repair online or call 01462 506374, answered 24 hours a day.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374