Skip to main content

Vantage Plumbing and Heating

Combi Boiler Error Codes: What the Common Ones Mean

Hertfordshire, Bedfordshire & Cambridgeshire

Fully Stocked Vans12 Month Labour GuaranteeGas Safe Registered 956889

A combi boiler error code tells you which of the boiler’s safety checks has failed, and although every manufacturer uses its own codes, most of them fall into a few groups: low water pressure, the boiler failing to light, water not circulating or overheating, and fan, sensor or electronics faults. Low pressure and a frozen condensate pipe can usually be sorted safely by the homeowner, but anything inside the boiler casing needs a Gas Safe registered engineer.

In short

  • The same code means different things on different brands, so always note the make and model with the code.
  • The most common codes are low pressure, ignition or flame failure, and circulation or overheat faults.
  • Safe checks: gas supply and prepay meter, the pressure gauge, the condensate pipe, the controls, then one or two resets.
  • If a code keeps coming back after a reset, the boiler needs an engineer.
  • Never remove the boiler casing. Work inside it is Gas Safe work by law.
Ideal boiler installed by Vantage in a fitted cupboard, with copper pipework and a magnetic system filter
One of our boiler installations: an Ideal combi in a fitted cupboard with a magnetic system filter.

How combi boiler error codes work

Every modern boiler constantly checks itself: is there enough water pressure, did the burner light, is the flame still there, is water moving, is the fan spinning at the right speed, are the temperatures within limits. When one of those checks fails, the boiler stops and shows a code.

Codes usually fall into two kinds:

  • Blocking or temporary faults stop the boiler until the condition clears, then it restarts on its own. Low pressure is a typical example.
  • Lockouts keep the boiler off until someone presses reset. Ignition failures and overheats usually cause a lockout, because the boiler wants a person to know something went wrong.

Brands write their codes differently. Vaillant and Glow-worm use F followed by a number (F.28). Ideal uses F and L codes (F1, L2). Worcester Bosch uses a two-character display code with a three-digit cause code (EA and 227). Newer Baxi boilers use a letter and four digits (E.04.10), while older Baxi models use E and two or three digits (E133).

The most common codes, by brand

These are among the most common codes on combi boilers. The meanings are taken from each manufacturer’s own fault code lists and user guides. Not every model uses every code, so treat your user guide as the final word.

BrandCodeWhat it meansCan you do anything?
VaillantF.22Low water pressure in the systemYes, top up the pressure if your user guide allows
VaillantF.28No flame detected when the boiler tried to lightCheck the gas, prepay meter and condensate pipe, then reset
VaillantF.29Flame lost while running and could not relightSame checks as F.28
VaillantF.75No pressure rise detected when the pump startedCheck the pressure, then call an engineer
IdealF1Low water pressureYes, top up to about 1 to 1.5 bar
IdealF2Flame lossCheck the gas and condensate pipe, then reset
IdealL2Ignition lockout: no flame detectedCheck the gas and condensate pipe, then reset
IdealL1Flow overheat or no water flowCheck pressure, bleed radiators, open valves, reset once
IdealF3Fan faultReset once, then engineer
Worcester BoschEA with 227No flame signal after ignitionCheck the gas and condensate pipe, then reset
Worcester BoschA1 with 281Pump stuck or running with air or too little waterCheck and top up the pressure
Worcester BoschE9Overheat protection has trippedCheck the pressure and radiator valves, then engineer
Worcester BoschC6Fan not running at the right speedCheck the flue terminal outside is clear, then engineer
Baxi (newer)E.04.10Burner failed to ignite after four attemptsCheck the gas and condensate pipe, then reset
Baxi (newer)H.02.07Low pressure in the heating circuitTop up the pressure
Baxi (newer)E.01.17No water circulationCheck the pressure, then engineer
Baxi (older)E133Gas supply or ignition faultCheck the gas and condensate pipe, then reset
Baxi (older)E118 or E119Low water pressure (E119 on some older models)Top up the pressure
Baxi (older)E125Water circulation faultCheck the pressure, then engineer
Glow-wormF.22Low water pressureTop up the pressure
Glow-wormF.28Failed to light, no flame detectedCheck the gas and condensate pipe, then reset

For full details on the most common lockouts, see our guides to Vaillant F28, Ideal L2 and Baxi E.04.10, and our full list of Worcester Bosch fault codes. If the code needs an engineer, our boiler repair service covers all the major makes.

What the code groups usually mean

Low pressure codes

A combi boiler runs on a sealed system that needs water pressure of around 1 to 1.5 bar when cold. If it drops too far, usually below about 0.5 to 1 bar depending on the model, the boiler stops. Topping up with the filling loop usually clears the code. If you have to do it more than once every few months, there is a leak somewhere or a faulty part, such as the pressure relief valve or expansion vessel. Our guide on a boiler that keeps losing pressure explains how to track it down.

Ignition and flame codes

These mean the boiler tried to light and did not see a flame, or lost the flame while running. The most common causes are no gas reaching the boiler (including an empty prepayment meter) and, in winter, a frozen condensate pipe backing up into the boiler. After those, it is usually the ignition electrode, flame sensing, the gas valve or the flue, all of which are engineer jobs.

Circulation and overheat codes

If water is not moving through the boiler, it heats up too quickly and the boiler shuts down to protect itself. Low pressure and air are the easy causes. A seized pump, sludge, a blocked heat exchanger or closed valves need an engineer.

Fan, sensor and electronics codes

The fan, temperature sensors and control board are all inside the sealed case. A reset can clear a one-off glitch, but if these codes come back, they need an engineer.

Check these first

  1. Photograph the display so you have the exact code, and note the make and model.
  2. Check the gas. Try a gas hob if you have one. On a prepayment meter, check there is credit.
  3. Check the pressure gauge. Most combis want around 1 to 1.5 bar when cold. Top up with the filling loop if your user guide shows you how.
  4. Check the condensate pipe in cold weather. If it is frozen, pour warm (not boiling) water over it. See our frozen condensate pipe guide.
  5. Check the power and controls. Make sure the fused spur is on, the thermostat is calling for heat and the timer is set.
  6. Reset once or twice, exactly as your user guide describes. If the code returns, stop and call an engineer.

What not to do

  • Do not remove the boiler casing or touch the gas valve, fan, circuit board, heat exchanger or flue. Under the Gas Safety (Installation and Use) Regulations 1998, only a Gas Safe registered engineer may work on a gas appliance.
  • Do not keep pressing reset. Some boilers block further resets after several attempts.
  • If you smell gas, open windows, do not use electrical switches, turn off the gas at the meter if it is safe, and call the National Gas Emergency Service on 0800 111 999.

What an engineer will check

An engineer will read the code and the boiler’s fault history, then test the relevant part: gas pressure and supply, ignition and flame sensing, the fan and flue, the pump, pressure sensor and expansion vessel, the diverter valve and temperature sensors. The code tells them where to start, which is why noting it before you reset is so useful.

Repair or replace?

Most error codes lead to a straightforward repair. It is worth talking about replacement when the boiler is old, parts are becoming hard to get, a major part such as the heat exchanger has failed, or the boiler has needed several repairs in a short time. We will give you an honest view either way.

What we charge to fix it

Our prices, before you ring

Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee£150 + VAT
£180 inc VAT
Evenings and weekends, first hour including the call-out£297.60
inc VAT
Overnight, first hour including the call-out£330
inc VAT
If a new boiler is the better answer, fittedfrom £2,780
inc VAT

The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.

Frequently asked questions

What is the most common combi boiler error code?

Low pressure and ignition failure codes are the most common across all brands. Low pressure is usually easy to fix by topping up, and ignition codes are often down to the gas supply or a frozen condensate pipe in winter.

How do I reset my combi boiler?

Most combis have a reset button, or a reset option in the menu, described in the user guide. Press it once and wait for the boiler to try again. If the same code comes back, do not keep resetting.

Can I clear a boiler error code myself?

You can clear codes caused by low pressure, a frozen condensate pipe, a gas supply problem or the controls. Codes pointing to parts inside the boiler, such as the fan, pump, sensors or ignition, need a Gas Safe registered engineer.

Why does my boiler show a code only in cold weather?

The usual reason is the condensate pipe freezing. When the pipe carrying water away from the boiler freezes, the water backs up and the boiler shuts down, often showing an ignition or flame code.

Do different boiler brands use the same error codes?

No. Each manufacturer has its own codes, and even two models from the same brand can use different systems. Always check the code against your model’s user guide or ask an engineer.

When to call an engineer

If the code keeps returning, points to a part inside the boiler, or you are not comfortable doing the checks, our Gas Safe registered engineers (registration 956889) can diagnose and fix it. Book a boiler repair or call 01462 506374, answered 24 hours a day, 7 days a week.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.