Combi Boiler Error Codes: What the Common Ones Mean
Hertfordshire, Bedfordshire & Cambridgeshire
A combi boiler error code tells you which of the boiler’s safety checks has failed, and although every manufacturer uses its own codes, most of them fall into a few groups: low water pressure, the boiler failing to light, water not circulating or overheating, and fan, sensor or electronics faults. Low pressure and a frozen condensate pipe can usually be sorted safely by the homeowner, but anything inside the boiler casing needs a Gas Safe registered engineer.
In short
- The same code means different things on different brands, so always note the make and model with the code.
- The most common codes are low pressure, ignition or flame failure, and circulation or overheat faults.
- Safe checks: gas supply and prepay meter, the pressure gauge, the condensate pipe, the controls, then one or two resets.
- If a code keeps coming back after a reset, the boiler needs an engineer.
- Never remove the boiler casing. Work inside it is Gas Safe work by law.

How combi boiler error codes work
Every modern boiler constantly checks itself: is there enough water pressure, did the burner light, is the flame still there, is water moving, is the fan spinning at the right speed, are the temperatures within limits. When one of those checks fails, the boiler stops and shows a code.
Codes usually fall into two kinds:
- Blocking or temporary faults stop the boiler until the condition clears, then it restarts on its own. Low pressure is a typical example.
- Lockouts keep the boiler off until someone presses reset. Ignition failures and overheats usually cause a lockout, because the boiler wants a person to know something went wrong.
Brands write their codes differently. Vaillant and Glow-worm use F followed by a number (F.28). Ideal uses F and L codes (F1, L2). Worcester Bosch uses a two-character display code with a three-digit cause code (EA and 227). Newer Baxi boilers use a letter and four digits (E.04.10), while older Baxi models use E and two or three digits (E133).
The most common codes, by brand
These are among the most common codes on combi boilers. The meanings are taken from each manufacturer’s own fault code lists and user guides. Not every model uses every code, so treat your user guide as the final word.
| Brand | Code | What it means | Can you do anything? |
|---|---|---|---|
| Vaillant | F.22 | Low water pressure in the system | Yes, top up the pressure if your user guide allows |
| Vaillant | F.28 | No flame detected when the boiler tried to light | Check the gas, prepay meter and condensate pipe, then reset |
| Vaillant | F.29 | Flame lost while running and could not relight | Same checks as F.28 |
| Vaillant | F.75 | No pressure rise detected when the pump started | Check the pressure, then call an engineer |
| Ideal | F1 | Low water pressure | Yes, top up to about 1 to 1.5 bar |
| Ideal | F2 | Flame loss | Check the gas and condensate pipe, then reset |
| Ideal | L2 | Ignition lockout: no flame detected | Check the gas and condensate pipe, then reset |
| Ideal | L1 | Flow overheat or no water flow | Check pressure, bleed radiators, open valves, reset once |
| Ideal | F3 | Fan fault | Reset once, then engineer |
| Worcester Bosch | EA with 227 | No flame signal after ignition | Check the gas and condensate pipe, then reset |
| Worcester Bosch | A1 with 281 | Pump stuck or running with air or too little water | Check and top up the pressure |
| Worcester Bosch | E9 | Overheat protection has tripped | Check the pressure and radiator valves, then engineer |
| Worcester Bosch | C6 | Fan not running at the right speed | Check the flue terminal outside is clear, then engineer |
| Baxi (newer) | E.04.10 | Burner failed to ignite after four attempts | Check the gas and condensate pipe, then reset |
| Baxi (newer) | H.02.07 | Low pressure in the heating circuit | Top up the pressure |
| Baxi (newer) | E.01.17 | No water circulation | Check the pressure, then engineer |
| Baxi (older) | E133 | Gas supply or ignition fault | Check the gas and condensate pipe, then reset |
| Baxi (older) | E118 or E119 | Low water pressure (E119 on some older models) | Top up the pressure |
| Baxi (older) | E125 | Water circulation fault | Check the pressure, then engineer |
| Glow-worm | F.22 | Low water pressure | Top up the pressure |
| Glow-worm | F.28 | Failed to light, no flame detected | Check the gas and condensate pipe, then reset |
For full details on the most common lockouts, see our guides to Vaillant F28, Ideal L2 and Baxi E.04.10, and our full list of Worcester Bosch fault codes. If the code needs an engineer, our boiler repair service covers all the major makes.
What the code groups usually mean
Low pressure codes
A combi boiler runs on a sealed system that needs water pressure of around 1 to 1.5 bar when cold. If it drops too far, usually below about 0.5 to 1 bar depending on the model, the boiler stops. Topping up with the filling loop usually clears the code. If you have to do it more than once every few months, there is a leak somewhere or a faulty part, such as the pressure relief valve or expansion vessel. Our guide on a boiler that keeps losing pressure explains how to track it down.
Ignition and flame codes
These mean the boiler tried to light and did not see a flame, or lost the flame while running. The most common causes are no gas reaching the boiler (including an empty prepayment meter) and, in winter, a frozen condensate pipe backing up into the boiler. After those, it is usually the ignition electrode, flame sensing, the gas valve or the flue, all of which are engineer jobs.
Circulation and overheat codes
If water is not moving through the boiler, it heats up too quickly and the boiler shuts down to protect itself. Low pressure and air are the easy causes. A seized pump, sludge, a blocked heat exchanger or closed valves need an engineer.
Fan, sensor and electronics codes
The fan, temperature sensors and control board are all inside the sealed case. A reset can clear a one-off glitch, but if these codes come back, they need an engineer.
Check these first
- Photograph the display so you have the exact code, and note the make and model.
- Check the gas. Try a gas hob if you have one. On a prepayment meter, check there is credit.
- Check the pressure gauge. Most combis want around 1 to 1.5 bar when cold. Top up with the filling loop if your user guide shows you how.
- Check the condensate pipe in cold weather. If it is frozen, pour warm (not boiling) water over it. See our frozen condensate pipe guide.
- Check the power and controls. Make sure the fused spur is on, the thermostat is calling for heat and the timer is set.
- Reset once or twice, exactly as your user guide describes. If the code returns, stop and call an engineer.
What not to do
- Do not remove the boiler casing or touch the gas valve, fan, circuit board, heat exchanger or flue. Under the Gas Safety (Installation and Use) Regulations 1998, only a Gas Safe registered engineer may work on a gas appliance.
- Do not keep pressing reset. Some boilers block further resets after several attempts.
- If you smell gas, open windows, do not use electrical switches, turn off the gas at the meter if it is safe, and call the National Gas Emergency Service on 0800 111 999.
What an engineer will check
An engineer will read the code and the boiler’s fault history, then test the relevant part: gas pressure and supply, ignition and flame sensing, the fan and flue, the pump, pressure sensor and expansion vessel, the diverter valve and temperature sensors. The code tells them where to start, which is why noting it before you reset is so useful.
Repair or replace?
Most error codes lead to a straightforward repair. It is worth talking about replacement when the boiler is old, parts are becoming hard to get, a major part such as the heat exchanger has failed, or the boiler has needed several repairs in a short time. We will give you an honest view either way.
What we charge to fix it
Our prices, before you ring
| Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee | £150 + VAT £180 inc VAT |
| Evenings and weekends, first hour including the call-out | £297.60 inc VAT |
| Overnight, first hour including the call-out | £330 inc VAT |
| If a new boiler is the better answer, fitted | from £2,780 inc VAT |
The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.
Frequently asked questions
What is the most common combi boiler error code?
Low pressure and ignition failure codes are the most common across all brands. Low pressure is usually easy to fix by topping up, and ignition codes are often down to the gas supply or a frozen condensate pipe in winter.
How do I reset my combi boiler?
Most combis have a reset button, or a reset option in the menu, described in the user guide. Press it once and wait for the boiler to try again. If the same code comes back, do not keep resetting.
Can I clear a boiler error code myself?
You can clear codes caused by low pressure, a frozen condensate pipe, a gas supply problem or the controls. Codes pointing to parts inside the boiler, such as the fan, pump, sensors or ignition, need a Gas Safe registered engineer.
Why does my boiler show a code only in cold weather?
The usual reason is the condensate pipe freezing. When the pipe carrying water away from the boiler freezes, the water backs up and the boiler shuts down, often showing an ignition or flame code.
Do different boiler brands use the same error codes?
No. Each manufacturer has its own codes, and even two models from the same brand can use different systems. Always check the code against your model’s user guide or ask an engineer.
When to call an engineer
If the code keeps returning, points to a part inside the boiler, or you are not comfortable doing the checks, our Gas Safe registered engineers (registration 956889) can diagnose and fix it. Book a boiler repair or call 01462 506374, answered 24 hours a day, 7 days a week.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374