Combi Boiler Valve Positions: Should the Valves Be Open or Closed?
Hertfordshire, Bedfordshire & Cambridgeshire
Under a combi boiler, the gas valve, the cold mains inlet valve and the heating flow and return valves should all be open in normal use, and the filling loop valves should be closed. As a rule, a valve is open when its handle or screwdriver slot lines up with the pipe, and closed when it sits at a right angle across the pipe.
In short
- Open in normal use: gas isolation valve, cold mains water inlet, central heating flow and return.
- Closed in normal use: both valves on the filling loop, or the internal filling lever or key.
- Handle or slot in line with the pipe means open. Across the pipe, at 90 degrees, means closed.
- A closed heating valve can cause overheating or no heating, a closed cold inlet means no hot water, and an open filling loop can push the pressure too high.
- If you find a valve closed and do not know why, do not simply open it. It may have been shut to isolate a leak.

The valves under a typical combi boiler
Look underneath most wall-hung combi boilers and you will see five or six pipes coming down, most with a valve on them. Exact layouts vary by make and model, and your boiler’s user guide or installation manual has a diagram, but the set is usually the same. If a valve is stiff, weeping or will not open fully, our boiler repair engineers can replace it.
| Valve or pipe | What it does | Normal position | How to tell |
|---|---|---|---|
| Gas isolation valve | Lets gas into the boiler | Open | Handle in line with the pipe. Your user guide diagram shows which pipe is gas |
| Cold mains inlet | Brings mains water in to make hot water | Open | Handle or slot in line with the pipe |
| Central heating flow | Sends hot water out to the radiators | Open | Handle or slot in line with the pipe |
| Central heating return | Brings cooler water back from the radiators | Open | Handle or slot in line with the pipe |
| Hot water outlet | Takes hot water to your taps | Usually has no valve | Nothing to set |
| Filling loop valves | Link the mains to the heating to top up pressure | Closed | Handle or slot across the pipe, or lever released |
| Pressure relief pipe | Safety outlet, copper, runs outside | Not a valve you operate | Should be dry |
| Condensate pipe | Plastic drain for condensing water | Not a valve | Drips normally when the boiler runs |
Some manufacturers colour the handles to help. On the Ideal Logic Max combi, for example, Ideal’s manual shows black handles on the heating flow and return valves and a blue handle on the domestic hot water inlet, all open when vertical, in line with the pipes, and a green handle for the filling loop. Other makes use plain valves with a screwdriver slot.
How to tell if a valve is open or closed
The rule works for almost every quarter-turn valve you will find on a boiler.
- Lever or handle valves. If the handle points along the pipe, the valve is open. If it sits across the pipe at a right angle, it is closed. This is the same rule as the emergency control valve on your gas meter: the gas network operators tell you to turn that handle a quarter turn, 90 degrees, to shut the gas off.
- Screwdriver slot valves. Many isolation valves have a slot instead of a handle. Worcester Bosch’s filling guide describes the slot being in line with the valve when open and across it when closed.
- Keyed filling loops. Some combis have a built-in filling loop operated by a removable key with padlock symbols. Worcester’s guide shows the open padlock as the position for filling, and the closed padlock as locked shut.
- Keyless filling levers. Some boilers have a lever under the casing that you hold down to fill and release to stop. Released is closed.
If a handle has been bent or fitted the wrong way round, or you simply cannot tell, check your user guide diagram before you move anything.
Symptoms of a valve in the wrong position
| What you notice | Likely valve | Why |
|---|---|---|
| No hot water, heating works | Cold mains inlet partly or fully closed | The boiler has no water to heat for the taps. See no hot water but heating works |
| Radiators cold, boiler fires then cuts out or shows an overheat fault | Heating flow or return closed | Water cannot circulate, so the boiler overheats and shuts down |
| Pressure keeps rising, water drips from the pipe outside | Filling loop left open or letting by | Mains water keeps feeding into the heating |
| Boiler will not light at all | Gas isolation valve closed | No gas is reaching the burner |
| Weak hot water flow | Cold mains inlet only partly open | Flow is restricted before the boiler |
What you can safely check yourself
These checks are safe for any homeowner. Look first, touch second.
- Turn the boiler off at the controls and let it cool if you plan to touch pipes. The pipes under a working boiler get hot.
- Find the diagram in your user guide and match each pipe to its valve.
- Check the filling loop is closed. If you have recently topped up the pressure, make sure both valves or the lever are fully shut. This is the most common valve left in the wrong position.
- Look at the pressure gauge. It should read roughly 1 to 1.5 bar cold. If it is too low, you can top it up with the filling loop as your user guide explains, then close it again. If it is too high, our boiler pressure guide explains what the readings mean.
- Note, but do not force, any valve that looks closed. Write down which one, then read the section below.
- Turn the boiler back on and see whether the symptom has changed.
Before you turn anything
- If the gas isolation valve under the boiler is closed and you did not close it, leave it closed and call an engineer. Someone may have shut it for a safety reason.
- If a water valve is closed, it may have been shut to isolate a leak or after a repair. Look for any signs of water before opening it, and open it slowly.
- Never remove the boiler casing or touch the gas valve, fan, circuit board, heat exchanger or anything inside the case. Under the Gas Safety (Installation and Use) Regulations 1998 only a Gas Safe registered engineer may work on a gas appliance.
- If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows, do not use electrical switches, and turn the gas off at the meter if it is safe to do so.
Why valves end up in the wrong position
Valves are rarely moved by accident. The usual reasons are:
- After a service or repair. Engineers close the heating and water valves to work on the boiler. A good engineer reopens them and checks the system before leaving, but it is worth knowing where they are.
- After topping up. The filling loop is the valve most often left open, sometimes only slightly.
- To isolate a leak. A previous occupant or tradesperson may have shut a valve to stop a drip from the boiler or a pipe.
- Old valves seizing. Isolation valves that have not been turned for years can stick partly closed, or start to weep at the spindle when finally moved.
- Stiff filling loop valves letting by. A worn filling loop can pass water even when the handle says closed, which slowly raises the pressure.
If a valve is stiff, weeping or will not fully open, it needs replacing rather than forcing. That is a quick job for an engineer.
What an engineer will check
- That every isolation valve opens and closes fully and does not weep.
- That the filling loop is sealing properly, and, on external loops, whether the hose should be disconnected after use, as many manufacturers instruct.
- The system pressure and the expansion vessel charge.
- Whether heating water is circulating properly through the boiler and radiators.
- Whether the gas supply to the boiler gives the correct working pressure.
What we charge to fix it
Our prices, before you ring
| Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee | £150 + VAT £180 inc VAT |
| Evenings and weekends, first hour including the call-out | £297.60 inc VAT |
| Overnight, first hour including the call-out | £330 inc VAT |
| If a new boiler is the better answer, fitted | from £2,780 inc VAT |
The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.
Frequently asked questions
Should the valves under my boiler be open or closed?
The gas valve, cold mains inlet and heating flow and return valves should be open. The filling loop valves should be closed except when you are topping up the pressure.
How can I tell if a boiler valve is open or closed?
Look at the handle or screwdriver slot. In line with the pipe means open. At a right angle across the pipe means closed. If the valve has a lever or key, your user guide shows which position is which.
Should the filling loop be left open?
No. Leaving the filling loop open lets mains water keep feeding into the heating, so the pressure rises until the pressure relief valve opens. Close it as soon as the gauge reaches about 1 to 1.5 bar.
Why is the gas valve under my boiler off?
It may have been turned off during a repair, a service or a safety visit. If you did not turn it off and do not know why it is shut, do not turn it back on yourself. Call a Gas Safe registered engineer to check the boiler first.
Can a closed valve stop my radiators heating?
Yes. If the heating flow or return valve under the boiler is closed, water cannot circulate. The boiler will usually overheat and shut down, and the radiators will stay cold. If only one radiator is cold, the valves on that radiator are the more likely cause. Our guide to a radiator not heating up explains the checks.
Help from a Gas Safe engineer
If you have checked the valves and the boiler still is not working properly, or a valve is stiff, weeping or letting by, our own Gas Safe registered engineers (registration 956889) can put it right. We cover Hertfordshire, Bedfordshire and Cambridgeshire from our base in Stevenage and are rated 4.9 on Google. Book a boiler repair or call 01462 506374, answered 24 hours a day, 7 days a week.
Need help today?
Call and speak to a person, any hour, any day of the year, or get a fixed price quote online.
Get a fixed price quote Call 01462 506 374Rather have an engineer look at it?
Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374