Common Baxi Boiler Problems and What Causes Them
Hertfordshire, Bedfordshire & Cambridgeshire
The most common Baxi boiler problems are low water pressure, the boiler failing to light (often because of a gas supply issue or a frozen condensate pipe), no hot water while the heating still works, and water not circulating properly. Low pressure and a frozen condensate pipe can usually be sorted safely by the homeowner, but faults with the diverter valve, pump, fan, sensors or ignition need a Gas Safe registered engineer.
In short
- Baxi’s newer boilers (the 200, 400, 600 and 800 ranges) show codes such as E.04.10 or H.02.07. Older models such as the Duo-tec, Platinum and EcoBlue show codes such as E133 or E118.
- Low pressure is the most common problem, and topping up usually clears it.
- Ignition lockouts are often caused by a gas supply problem or a frozen condensate pipe.
- No hot water with working heating usually points to the diverter valve.
- Never remove the casing. Anything inside the boiler is a job for a Gas Safe registered engineer.
Common Baxi boiler problems at a glance
Baxi has made a lot of boilers over the years, so the codes you see depend on the model. The table shows the most common problems on Baxi boilers, with the codes from Baxi’s own lists. Our boiler repair engineers work on every Baxi range.
| Problem | Codes you may see | Common causes | Can you fix it yourself? |
|---|---|---|---|
| Low water pressure | A.02.06, H.02.07 (newer). E118, or E119 on some older models | Leak, pressure relief valve, bled radiators, expansion vessel | Yes, top up. If it keeps dropping, no |
| Boiler will not light | E.04.10 (newer). E133 (older) | Gas supply, prepay meter, frozen condensate, ignition or flame sensing | Some checks, then engineer |
| No water circulation | H.01.18, E.01.17 (newer). E125 (older) | Low pressure, air, stuck pump, sludge, closed valves | Pressure and air only |
| Overheating | E110 (older) | Poor circulation, pump, sludge, sensor | Pressure and air only |
| Fan fault | E160 (older) | Fan, wiring, blocked flue | Check the flue terminal outside only |
| Sensor faults | E20, E28 (older) | Failed temperature sensor or wiring | No |
| No hot water, heating works | Often no code | Diverter valve, hot water settings | Check the settings only |
| Pressure too high, dripping pipe outside | Often no code | Filling loop left open, expansion vessel, internal fault | Check the filling loop is closed |
| Noisy boiler | No code | Air, limescale, sludge, pump | Bleed radiators only |
Low water pressure
This is the most common Baxi problem of all. Baxi boilers run on a sealed system, and if the pressure drops too far, the boiler shuts down. On older models Baxi’s list gives E118 as water pressure low (below 0.5 bar). On the newer range, A.02.06 is a low pressure warning and H.02.07 means the pressure is too low for the boiler to run.
What you can do: Check the gauge with the heating cold. If it is below about 1 bar and your user guide shows how, top it up using the filling loop to around 1 to 1.5 bar, then close the loop fully.
When to call an engineer: If you are topping up more than once every few months, there is a leak, a failing pressure relief valve or an expansion vessel that has lost its charge. Our guide to Baxi and Potterton E119 explains the causes in more detail.
Boiler will not light (ignition lockout)
On newer Baxi boilers, E.04.10 means the burner failed to ignite after four attempts. On older models, E133 means the boiler could not establish or detect a flame, which Baxi’s list describes as a gas supply fault. Either way, the boiler has locked out for safety.
What you can do:
- Check other gas appliances, such as the hob, are working.
- On a prepayment meter, check there is credit.
- In cold weather, check the condensate pipe (see below).
- Reset the boiler once or twice as your user guide describes.
When to call an engineer: If it locks out again, the cause is usually the ignition or flame sensing electrodes, the gas valve, the fan or the flue. Our Baxi E133 guide goes through it step by step.
Frozen condensate pipe
Baxi’s own advice for a boiler that has stopped includes checking for frozen pipes, especially the condensate pipe. This plastic pipe carries acidic water from the boiler to a drain. When it runs outside and the weather turns cold, it can freeze, the water backs up and the boiler locks out, often with an ignition code and sometimes with a gurgling sound.
What you can do: Find the frozen section, usually at a bend or the open end outside, and pour warm (not boiling) water over it until it clears, then reset the boiler. Our frozen condensate pipe guide has the details. If it freezes every winter, an engineer can reroute or insulate it.
No hot water but the heating works
On a Baxi combi, a diverter valve inside the boiler sends hot water either to the taps or the radiators. Baxi itself points to the diverter valve when the heating works but there is no hot water. If it sticks, you get hot radiators and cold taps.
What you can do: Check the hot water temperature setting, and that the boiler is not in a heating-only or holiday mode. On a system boiler with a cylinder, check the hot water timer and cylinder thermostat.
When to call an engineer: If the settings are right, the diverter valve or a hot water sensor is the likely cause, both inside the boiler. Read our guide on no hot water but the heating works for more.
Circulation and overheating faults
If water is not moving through the boiler, it heats up too fast and shuts down. On newer Baxi boilers this shows as H.01.18 (temporary) or E.01.17 (permanent). On older models, E125 is a water circulation fault and E110 is an overheat.
What you can do: Check the pressure, top up if it is low, bleed any radiators that are cold at the top, and make sure radiator valves are open. Reset once.
When to call an engineer: If it returns, the likely causes are a stuck or failing pump, sludge in the system or the boiler’s heat exchanger, or a failed sensor. Our Baxi E125 guide covers circulation faults in detail.
Fan and sensor faults
E160 on older Baxi boilers is a fan fault. E20 and E28 are temperature sensor faults (central heating and flue sensors). These are all inside the sealed case. Apart from checking the flue terminal outside is not blocked by a nest, leaves or snow, there is nothing a homeowner should do. A reset may clear a one-off glitch, but if the code returns, call an engineer.
Pressure too high or a dripping pipe outside
If the gauge reads well above the normal range, or a copper pipe outside near the boiler is dripping, the pressure relief valve may be letting water out. Check the filling loop is fully closed. If it is, the likely causes are an expansion vessel that has lost its charge, or a fault inside the boiler letting mains water into the heating. Both need an engineer.
Noisy Baxi boiler
A Baxi boiler that gurgles, bangs or makes a kettle-like noise usually has air in the system, low pressure, a struggling pump, or limescale or sludge restricting the flow through the heat exchanger. Hard water across most of Hertfordshire makes limescale more likely. Bleeding radiators and checking the pressure are safe first steps. Persistent noise needs an engineer, and sometimes a system clean.
What not to do
- Do not remove the boiler casing or touch anything inside it. Under the Gas Safety (Installation and Use) Regulations 1998, only a Gas Safe registered engineer may work on a gas appliance.
- Do not keep resetting a boiler that keeps locking out.
- Do not use boiling water on a frozen condensate pipe.
- If you smell gas, open windows, do not use electrical switches, turn off the gas at the meter if it is safe, and call the National Gas Emergency Service on 0800 111 999.
How to prevent Baxi boiler problems
- Have it serviced every year. A boiler service catches worn parts, checks the flue and combustion, and keeps the manufacturer’s guarantee valid where it requires servicing.
- Keep an eye on the pressure gauge. A slow drop is the first sign of a leak.
- Protect the condensate pipe if it runs outside.
- Look after the system water. A magnetic filter and inhibitor reduce sludge, which causes many circulation and noise problems.
- Use Baxi’s holiday or frost setting rather than switching the boiler off completely in summer, as Baxi suggests, so parts do not seize.
What we charge to fix it
Our prices, before you ring
| Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee | £150 + VAT £180 inc VAT |
| Evenings and weekends, first hour including the call-out | £297.60 inc VAT |
| Overnight, first hour including the call-out | £330 inc VAT |
| If a new boiler is the better answer, fitted | from £2,780 inc VAT |
The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.
Frequently asked questions
How do I reset my Baxi boiler?
Baxi boilers have a reset button or reset function described in the user guide for your model. Press it once and wait for the boiler to try again. If the fault returns, stop resetting and call a Gas Safe engineer.
Why does my Baxi boiler keep losing pressure?
Usually because of a leak somewhere in the system, a pressure relief valve letting water out, or an expansion vessel that has lost its charge. Bleeding radiators also lowers the pressure. If you have to top up regularly, an engineer should find the cause.
Are Baxi boilers reliable?
Baxi is one of the UK’s best-known boiler makers, and a well-installed, annually serviced Baxi boiler should give many years of service. Most of the problems in this guide are caused by the system or conditions around the boiler rather than a flaw in the boiler itself.
How long does a Baxi boiler last?
Like most modern gas boilers, a Baxi boiler typically lasts well over a decade with regular servicing. The age, how well it was installed, the condition of the system water and whether parts are still available all affect when it is worth replacing.
Can I fix a Baxi fault code myself?
You can deal with codes caused by low pressure, a frozen condensate pipe, a gas supply problem or the controls. Codes pointing to the fan, sensors, pump, ignition or diverter valve need a Gas Safe registered engineer.
When to call an engineer
If your Baxi boiler keeps showing the same code, will not light after the safe checks, or has no hot water, our Gas Safe registered engineers (registration 956889) repair and service all Baxi models. Book a boiler repair or call 01462 506374, answered 24 hours a day, 7 days a week.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.