The most common boiler problems are low pressure, no heating or hot water, a boiler that will not fire up or keeps locking out, strange noises, leaks, a frozen condensate pipe in winter and radiators that stay cold. Several of these you can safely check or fix yourself, such as repressurising, resetting the controls or thawing the condensate pipe, but anything inside the boiler casing needs a Gas Safe registered engineer.
- Low pressure is the most common cause of a boiler stopping. Most boilers want around 1 to 1.5 bar when cold, but check your user guide.
- A frozen condensate pipe is a very common winter fault and can usually be thawed with warm water.
- Many “boiler faults” are actually controls: a thermostat set too low, a timer in the wrong mode or flat batteries.
- A fault code on the display tells an engineer where to start. Note it down before you call.
- Leaks, gas smells, repeated lockouts and anything inside the case are jobs for a Gas Safe engineer.

Common boiler problems at a glance
| Problem | Likely causes | What you can safely check | When to call an engineer |
|---|---|---|---|
| No heating or hot water | Low pressure, controls, power, gas supply, frozen condensate | Pressure gauge, thermostat, timer, power, other gas appliances | If checks do not fix it or a fault code returns |
| Boiler losing pressure | Leak on the system, faulty pressure relief valve, expansion vessel | Look for drips under the boiler and on radiators, repressurise if the manual allows | If you top up more than occasionally |
| Boiler will not fire up | Gas supply, ignition fault, flame sensor, fan or pressure switch | Other gas appliances, prepay meter credit, reset once or twice | If it locks out again after a reset |
| No hot water but heating works | Diverter valve (combi), zone valve or cylinder thermostat | Programmer and hot water settings | Almost always |
| Banging, kettling or gurgling | Limescale, sludge, air, pump fault | Bleed radiators if there is air | If the noise continues |
| Leaking or dripping | Failed seal, pressure relief valve, corroded component | Note where the water is coming from and turn the boiler off if it is heavy | Always |
| Boiler keeps switching off | Low pressure, blocked system, thermostat, overheating | Pressure and thermostat position | If it keeps happening |
| Radiators cold or cold spots | Air, sludge, balancing, stuck valve | Bleed the radiator, check the valve | If bleeding does not help |
| Boiler stopped in freezing weather | Frozen condensate pipe | Thaw the pipe with warm water | If it does not restart |
No heating or hot water
When a boiler gives you nothing at all, start with the simple things. Check the pressure gauge, make sure the boiler has power and the fused spur is on, check the timer and thermostat are calling for heat, and see whether your gas hob works. If you have a prepayment meter, check it has credit. Work through these in order before assuming the boiler itself has failed.
If the display shows a fault code, write it down. Codes differ between makers. We have guides for many of them, and if you cannot find a solution, our boiler repair engineers can diagnose it.
Low pressure and a boiler that keeps losing it
Modern boilers on a sealed system need the right water pressure to run. Vaillant gives about 1.5 bar as a typical level, and most boilers want somewhere around 1 to 1.5 bar when the system is cold. If it falls too low, the boiler stops and usually shows a fault code.
You can usually top it up using the filling loop, if your boiler’s user guide allows it. If you need to top up more than once or twice a year, water is escaping somewhere: a leak on a radiator valve or pipe, a pressure relief valve letting by, or an expansion vessel that has lost its charge. Our guide to a boiler that keeps losing pressure explains how to tell which.
Boiler not firing up or locking out
If the boiler tries to light and then locks out, it has not detected a flame. Common causes include a problem with the gas supply, a faulty ignition electrode or flame sensor, a blocked condensate pipe or a fault with the fan or air pressure switch. Check your other gas appliances work and press reset once or twice. If it keeps locking out, stop resetting and call an engineer, because repeated resets will not fix the cause. Our guide to a boiler not firing up goes into more detail.
Older boilers with a pilot light can have a similar problem when the pilot keeps going out. Relighting it is covered in the user guide on those models. If it will not stay lit, a Gas Safe engineer needs to check it.
No hot water but the heating works
On a combi boiler, this usually points to the diverter valve, which switches the boiler between heating and hot water. On a system with a cylinder, it is often the motorised zone valve, the cylinder thermostat or the programmer. Check the hot water is switched on and the programmer is not in heating only mode. Our guide to no hot water but the heating works covers both kinds of system.
Noises: banging, kettling and gurgling
- Kettling sounds like a kettle boiling. It is usually caused by limescale or sludge on the heat exchanger restricting the flow, which is common in the hard water areas across most of Hertfordshire.
- Banging can come from the boiler overheating in places because of restricted flow, from a pump fault, or from pipes moving as they heat up.
- Gurgling usually means air in the system. Bleeding the radiators often cures it.
If a noise does not stop after bleeding, an engineer will check the flow through the boiler, the pump and the condition of the system water.
Leaks and drips
A leak from the boiler itself is not something to live with. Water inside the case can damage electrical parts. Common sources are perished seals, the pressure relief valve, the pump or a corroded component. If the leak is heavy, turn the boiler off and isolate the water if you can, then call an engineer. Do not remove the casing to look.
Frozen condensate pipe
A condensing boiler produces water that drains away through a plastic pipe, often outside. In freezing weather that water can freeze and block the pipe, and the boiler shuts down, often with a fault code and a gurgling sound. You can usually thaw it by pouring warm (not boiling) water over the outside section of the pipe, then resetting the boiler. Our guide to a frozen condensate pipe shows how.
Radiators cold or with cold spots
Cold at the top usually means air, which bleeding fixes. Cold at the bottom or in the middle usually means sludge, which needs the system cleaning. One radiator cold while others are hot can be a stuck valve or a system that needs balancing. Our guide to a radiator not heating up covers each case.
Stay safe while you check
- If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows, do not use electrical switches and turn off the gas at the meter if it is safe to do so.
- Never remove the boiler casing or touch anything inside it, including the gas valve, fan, circuit board, heat exchanger or flue.
- Do not keep pressing reset. A couple of attempts is enough.
- If your carbon monoxide alarm sounds, get everyone out into fresh air and call 0800 111 999.
Repair or replace?
Most boiler problems are repairs, not a reason to replace the boiler. Replacement starts to make sense when a boiler is old, parts are hard to get, the same faults keep coming back, or a major part such as the heat exchanger has failed on an older boiler. Age alone is not a reason to replace a boiler that is safe and reliable, but it is worth planning ahead once repairs become regular.
What we charge to fix it
Our prices, before you ring
| Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee | £150 + VAT £180 inc VAT |
| Evenings and weekends, first hour including the call-out | £297.60 inc VAT |
| Overnight, first hour including the call-out | £330 inc VAT |
| If a new boiler is the better answer, fitted | from £2,780 inc VAT |
The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.
Frequently asked questions
What is the most common problem with boilers?
Low pressure is one of the most common reasons a boiler stops working, along with problems with the controls and, in winter, frozen condensate pipes. All three can often be sorted without an engineer, if the user guide allows you to repressurise.
Why is my boiler running but not heating?
Check the thermostat is set above the room temperature and the programmer is calling for heating. If the boiler is firing but radiators stay cold, the cause may be a pump fault, a stuck diverter or zone valve, air or sludge in the system.
Is it safe to keep resetting my boiler?
Pressing reset once or twice is fine. If the boiler keeps locking out, there is an underlying fault that needs finding, and repeatedly resetting it will not fix it.
Should I turn my boiler off if it is leaking?
Yes, if the leak is more than a small drip. Turn it off, isolate the water if you can, put a container underneath and call an engineer. Water and electrics inside the boiler do not mix.
Can I fix my boiler myself?
You can check the pressure and top it up if the user guide allows, bleed radiators, check the controls and thaw a frozen condensate pipe. Anything inside the boiler casing is gas work and must be done by a Gas Safe registered engineer.
Boiler repairs in Hertfordshire, Bedfordshire and Cambridgeshire
If your boiler is showing a fault, losing pressure or making new noises, our Gas Safe registered engineers (registration 956889) repair all the major brands. See our boiler repair page or call 01462 506374. The phone is answered 24 hours a day, 7 days a week, and we offer 24/7 emergency cover.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374