Common Vokera Boiler Problems and What Causes Them
Hertfordshire, Bedfordshire & Cambridgeshire
The most common Vokera boiler problems are low system pressure, the boiler failing to light, heating or hot water not working while the other does, and a blocked or frozen condensate pipe, followed by fan, sensor and overheating faults. Many Vokera boilers show a code starting with A, such as A04 for low water pressure, and checking the pressure, gas and condensate is safe to do yourself, but anything inside the case needs a Gas Safe registered engineer.
In short
- Low pressure (A04 on many models) is one of the most common Vokera problems. Top up if your user guide allows, then find out why it dropped.
- A01 on current models means the boiler could not light or detect its flame. Check the gas and condensate first.
- Hot water but no heating, or the reverse, usually points to a diverter valve or the controls.
- A frozen condensate pipe causes winter lockouts. Thaw it with warm water, never boiling.
- Vokera boilers are repairable, and parts are widely available.
Vokera boilers and their fault codes
Vokera has made boilers for the UK market for many years, including the Compact, Unica, Vision, Easi-Heat, Mynute, Linea, Evolve and Vibe ranges. Most current Vokera boilers display fault codes in an A series, while some models, such as the Vision Plus, use E codes instead. Older models may show a flashing light pattern rather than a code, so the user guide for your model is always the final word. We carry out Vokera boiler repair work on all of these ranges.
This is how Vokera’s user instructions for the Mynute i, a typical current model, describe the main A codes:
| Code | What Vokera says it means | What to do first |
|---|---|---|
| A01 | Ignition failure, flame not sensed | Check gas and condensate, then reset |
| A02 | Limit thermostat fault (overheat) | Check pressure and bleed radiators, then reset |
| A03 | Fan fault | Reset once. If it returns, call an engineer |
| A04 | Insufficient system water pressure | Top up to the correct pressure, then reset |
| A07 | Primary thermistor fault | Reset. If it returns, call an engineer |
| A08 | Return thermistor fault | Reset. If it returns, call an engineer |
| A09 | Flue thermistor fault | Call an engineer |
| A11 | False flame | Call an engineer |
On some models the labels differ. The Easi-Heat Plus user guide, for example, lists A01 as an electronics fault and A02 as a flue or air intake obstruction, and the Vision Plus lists E010 as a flame lockout or blocked condensate discharge. Always check the guide for your model.
The most common Vokera boiler problems
1. Low pressure or a boiler that keeps losing pressure
Vokera advises that a sealed system should be at about 1 bar and never higher than 1.5 bar. The Easi-Heat Plus guide says the gauge should read between 1 and 1.5 bar when the boiler is off and cool, with 0.5 bar as the minimum for safe operation. Below that, the boiler stops and shows A04 or its equivalent.
Topping up with the filling loop is usually something you can do yourself if the user guide shows you how. The real question is why it dropped. A system that needs topping up more than a few times a year is losing water from a leak, a weeping pressure relief valve or a failing expansion vessel. If water is dripping from a copper pipe outside, Vokera notes the pressure may be too high. Our guide to a boiler that keeps losing pressure explains the causes.
2. The boiler will not light
A01 on most current models means the boiler tried to light and could not detect a flame. Vokera’s own checklist for a boiler that will not light is to check your prepayment meter has credit, check for any disruption to the gas supply and check the gas tap is in the correct position. In winter, a frozen condensate pipe is a common cause. If those are fine, the usual suspects are the ignition or flame sensing electrode, the ignition leads, the gas valve or low gas pressure. See our guide to a boiler not firing up.
3. Hot water but no heating, or heating but no hot water
On a Vokera combi, a diverter valve sends hot water either to the taps or to the radiators. When it sticks, you get one without the other. Before blaming the valve, check the timer, the room thermostat and, for hot water, that the mode setting has not been changed. On system boilers with a cylinder, a failed zone valve does the same job. See no hot water but the heating works.
4. Frozen or blocked condensate pipe
Condensing boilers drain acidic water through a plastic pipe, usually to an outside drain. In a hard frost that water freezes, the pipe blocks and the boiler locks out, often with a gurgling noise first. Vokera’s guidance calls for external condensate pipework to be at least 32 mm and insulated. Thawing it is a safe job with warm water or a hot water bottle, as our frozen condensate pipe guide explains.
5. Overheating and the limit thermostat
A02 on many models means the limit thermostat has tripped because the boiler got too hot. The water is not moving fast enough to carry the heat away, usually because of low pressure, air, a failing pump or sludge. Bleeding radiators and checking the pressure are safe first steps. Repeated overheating needs an engineer.
6. Fan and sensor faults
Fan faults (A03) and thermistor faults (A07, A08, A09) usually mean a part has failed or a connection has worked loose. A reset may clear a one-off, but these are engineer jobs.
7. Noisy boiler or kettling
A boiler that bangs, rumbles or sounds like a kettle has limescale or sludge in its heat exchanger, or poor flow. Hard water across most of Hertfordshire makes limescale a common cause. A system clean and a magnetic filter help prevent it coming back.
Check these first
- Read the code and write it down. Look it up in your user guide.
- Check the pressure gauge. Between 1 and 1.5 bar when the boiler is cold. Top up only if your user guide allows.
- Check the gas. Does the hob light? Does a prepay meter have credit?
- Check the power. Vokera suggests checking the boiler is switched on at the wall and the fuse has not blown, especially after the summer.
- Check the controls. Timer and room thermostat on and calling for heat.
- In freezing weather, check the condensate pipe and thaw it if needed.
- Reset once or twice. Depending on the model, you press a reset button or turn the mode selector to the reset position. The Easi-Heat Plus guide says to wait two minutes before resetting.
If the code comes back, stop resetting and book an engineer.
What not to do
- Do not keep resetting a boiler that keeps locking out.
- Do not remove the casing or touch the gas valve, fan, electrodes, diverter valve or control board. Under the Gas Safety (Installation and Use) Regulations 1998 only a Gas Safe registered engineer may work on a gas appliance.
- Do not overfill the system. Too much pressure makes the pressure relief valve discharge.
- If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows, do not use electrical switches and turn off the gas at the meter if it is safe.
Common causes at a glance
| Cause | What you might notice | Can you fix it yourself? | What the engineer does |
|---|---|---|---|
| Low pressure | A04, gauge below 1 bar | Yes, by topping up if allowed | Finds the leak, checks the expansion vessel and relief valve |
| No gas or ignition fault | A01, boiler will not light | Only meter credit or the gas tap | Checks gas pressure, electrodes and gas valve |
| Frozen condensate | Winter lockout, gurgling | Yes, with warm water | Clears the trap, insulates or reroutes the pipe |
| Diverter valve | Hot water or heating, not both | No | Replaces the valve or its motor |
| Poor circulation | A02, overheating, cold radiators | Partly, by bleeding | Checks the pump, cleans the system |
| Failed sensor or fan | A03, A07 to A09 | No | Tests and replaces the part |
| Scale or sludge | Kettling, banging | No | Descales or cleans the system, fits a filter |
Is Vokera a good boiler brand?
Vokera makes solid, affordable boilers that are widely fitted in UK homes, and they are straightforward for engineers to work on. Like any brand, how well one performs depends on the installation, the condition of the system and whether it is serviced every year. We repair and service Vokera boilers along with all the other major makes. When a Vokera needs replacing, we will give you honest advice on the options.
Repair or replace?
Most Vokera problems are repairable, and many, like pressure and condensate faults, cost little to put right. Consider replacement if the boiler is over about 12 to 15 years old, a major part such as the heat exchanger or control board has failed, or breakdowns are becoming regular. Installations are quoted as a fixed price after a free survey, so the price you agree is the price you pay.
What we charge to fix it
Our prices, before you ring
| Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee | £150 + VAT £180 inc VAT |
| Evenings and weekends, first hour including the call-out | £297.60 inc VAT |
| Overnight, first hour including the call-out | £330 inc VAT |
| If a new boiler is the better answer, fitted | from £2,780 inc VAT |
The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.
Frequently asked questions
Where is the reset on a Vokera boiler?
It depends on the model. Some have a reset button and others reset by turning the mode selector to the reset position. Your user guide shows which, and the Easi-Heat Plus guide says to wait two minutes before resetting.
Why does my Vokera keep losing pressure?
Water is escaping from the sealed system, usually through a leak on the pipework or radiators, a pressure relief valve that is letting by, or an expansion vessel that has lost its charge. Topping up only treats the symptom.
Why is my Vokera boiler showing a red light?
On many Vokera models a red light means the boiler has locked out and needs a reset. Check the code or light pattern in your user guide, check pressure, gas and condensate, then reset once or twice.
How long do Vokera boilers last?
With annual servicing, a gas boiler typically lasts 10 to 15 years, and Vokera boilers are similar. Reliability depends more on installation and maintenance than on the brand.
Can I fix a Vokera A01 myself?
You can check the gas supply, meter credit and condensate pipe, then reset. If A01 returns, an engineer needs to check the ignition, flame sensing and gas supply.
When to call an engineer
If a Vokera code keeps coming back, the pressure keeps dropping or the boiler will not light after the safe checks, it needs an engineer. We repair Vokera boilers across Hertfordshire, Bedfordshire and Cambridgeshire. We are Gas Safe registered (956889), our vans are fully stocked and our phone is answered 24 hours a day. Book a boiler repair or call 01462 506374.
Need help today?
Call and speak to a person, any hour, any day of the year, or get a fixed price quote online.
Get a fixed price quote Call 01462 506 374Rather have an engineer look at it?
Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.