E1 Boiler Fault Code: What It Means and What to Do
Hertfordshire, Bedfordshire & Cambridgeshire
E1 on a boiler display is usually not a fault code on its own: on many Baxi and Potterton boilers with a two-digit display, a three-digit code such as E119 or E133 is shown as “E1” alternating with the last two digits. Watch the display for a few seconds to read the full code, because the meaning, and whether you can fix it yourself, depends entirely on those next two digits.
In short
- Baxi and Potterton manuals explain that three-digit codes are shown as “E1” alternating with the rest, so E133 appears as “E1” then “33”.
- The most common full codes are E119 (low water pressure) and E133 (gas supply or flame failure).
- Low pressure is something you can usually fix yourself with the filling loop. Most other E1 codes need a Gas Safe registered engineer.
- Reset the boiler once or twice at most. If the code returns, stop and book a repair.
- If your display shows E1 on its own and never changes, check your own boiler’s user guide, because other makes use different code systems.

Why your boiler shows E1
Many Baxi and Potterton boilers, including models such as the Baxi Platinum Combi HE, the Baxi Duo-tec Combi HE and the Potterton Promax HE Plus range, have a small two-digit display. Their fault codes are either two or three digits long, always starting with E. The manufacturer’s installation manuals explain how they fit on the screen: a code such as E133 is displayed as “E1” alternating with “33”, while a two-digit code such as E20 is shown as “E” then “20”.
So when you glance at the boiler and see E1, you are usually seeing the first half of a longer code. Stand in front of the display for ten seconds and write down the digits that follow. That full code is what an engineer, or the user guide, will need, and it is the first thing we ask for when you book a boiler repair.
What the full E1 codes mean
These are the E1 codes listed in Baxi and Potterton installation manuals for the ranges above. The wording varies slightly from model to model, and newer Baxi boilers use some different numbers, so treat this as a guide and check your own manual.
| Display shows | Full code | Meaning in the manufacturer’s manual | Can you do anything yourself? |
|---|---|---|---|
| E1 then 10 | E110 | Safety thermostat operated, an overheat of the primary water | Check the pressure and bleed radiators, then reset once |
| E1 then 19 | E119 | Water pressure switch not operated. The pressure has fallen below about 0.5 bar | Usually yes, top up the pressure |
| E1 then 25 | E125 | Circulation fault in the primary circuit, or a pump problem | Check the pressure and bleed radiators |
| E1 then 30 | E130 | Flue NTC operated, a flue overheat. On some storage combis this code means the tank thermistor is out of place | No, apart from one reset |
| E1 then 33 | E133 | Interruption of gas supply or flame failure | Check the gas supply and condensate pipe, then reset once |
| E1 then 60 | E160 | Fan or fan wiring fault | No |
| E1 then 93 | E193 | Pre-circulation fault | Check the pressure and bleed radiators |
On newer Baxi models, low water pressure is shown as E118 and frequent flame loss as E128. If you have a boiler with a larger display that shows the whole code at once, you will not see E1 on its own.
Check these first
These are the safe checks any homeowner can make. They cover the most common E1 codes.
- Read the full code. Watch the display until you have seen the digits after E1. Write it down along with the boiler make and model from the label.
- Check the pressure gauge. With the system cold it should read roughly 1 to 1.5 bar. If it is below about 0.5 bar, you are almost certainly looking at E119. Top it up with the filling loop as your user guide shows, then close the filling loop fully.
- Check the gas supply. If the full code is E133, see whether your hob or other gas appliances work, and whether a prepayment meter has credit. If nothing lights, the problem is the supply, not the boiler.
- Look at the condensate pipe in cold weather. A frozen condensate pipe can stop the boiler lighting. Pour warm, not boiling, water over the frozen section outside at ground level.
- Bleed the radiators. For overheat and circulation codes such as E110, E125 and E193, trapped air or low pressure is sometimes the cause. Bleed any radiators that are cold at the top, then recheck the pressure.
- Reset once. Baxi’s manuals describe resetting by turning the selector to the reset position for at least five seconds on some models. Other models have a reset button. Your user guide shows which. If the code returns, stop.
What not to do
- Do not keep resetting the boiler. If the same code keeps coming back, something needs fixing, and repeated resets can make it worse or lock the boiler out.
- Do not remove the casing or touch the fan, gas valve, pump, circuit board, heat exchanger or flue. Under the Gas Safety (Installation and Use) Regulations 1998 only a Gas Safe registered engineer may work on a gas appliance.
- Do not overfill when topping up. Stop at 1 to 1.5 bar, or the pressure relief valve may open.
- If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows, do not use electrical switches, and turn the gas off at the meter if it is safe to do so.
Common causes behind E1 codes
| Cause | What you might notice | Can you fix it yourself? | What the engineer does |
|---|---|---|---|
| Low system pressure (E119 or E118) | Gauge below about 0.5 bar, no heating or hot water | Yes, top up with the filling loop | Finds the leak or recharges the expansion vessel if it keeps dropping |
| No gas or prepayment meter empty (E133) | Hob will not light either | Yes, top up or contact your supplier | Nothing needed at the boiler |
| Frozen condensate pipe (E133) | Cold weather, gurgling before shutdown | Yes, if the frozen section is outside and reachable | Clears the trap, insulates or reroutes the pipe |
| Air or sludge restricting flow (E110, E125, E193) | Banging or kettling noises, cold spots on radiators | Partly, by bleeding radiators | Checks the pump, cleans the system, fits a filter |
| Failed pump (E125) | Boiler fires then shuts off quickly, pipes stay cool | No | Tests and replaces the pump |
| Worn electrode or ignition parts (E133) | Boiler clicks but does not light, or lights and goes out | No | Checks electrodes, gas pressure and the gas valve |
| Fan fault (E160) | Boiler will not start, no fan noise | No | Tests the fan and its wiring, replaces as needed |
What an engineer will check
A good engineer starts from the full code and the manufacturer’s fault-finding chart for your exact model, rather than swapping parts on a guess. Depending on the code, that means measuring the system pressure and the expansion vessel charge, checking the pump runs and water circulates, testing temperature sensors and the safety thermostat, checking gas pressure at the boiler inlet, inspecting the ignition and flame detection electrodes, checking the flue, and testing the fan and circuit board connections. After any gas-side repair, the engineer should check combustion with a flue gas analyser before leaving.
Our engineers repair Baxi and Potterton boilers alongside all the other major brands.
Repair or replace?
Most E1 codes lead to routine repairs: a pressure top-up, a pump, an electrode, a sensor. They are rarely, on their own, a reason to replace a boiler. Replacement makes more sense if the boiler is well past ten years old, needs a major part such as a heat exchanger or circuit board, or has needed several repairs in a short time. If you want to compare, you can get a fixed price online with our boiler quote tool.
What we charge to fix it
Our prices, before you ring
| Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee | £150 + VAT £180 inc VAT |
| Evenings and weekends, first hour including the call-out | £297.60 inc VAT |
| Overnight, first hour including the call-out | £330 inc VAT |
| If a new boiler is the better answer, fitted | from £2,780 inc VAT |
The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.
Related codes
- E119, low water pressure: see the Baxi and Potterton E119 guide.
- E133, gas supply or ignition fault: see the Baxi E133 fault code guide.
- E125, circulation fault: see the Baxi E125 fault code guide.
Frequently asked questions
What does E1 mean on a Baxi combi boiler?
On many Baxi combis, E1 is the first part of a three-digit code shown in two halves. Watch the display for the next two digits: E1 then 19 means E119, low water pressure, and E1 then 33 means E133, a gas supply or flame failure.
Can I fix the E1 error myself?
Sometimes. If the full code is E119 or E118, topping up the pressure with the filling loop usually clears it. If it is a gas supply problem, such as an empty prepayment meter, fixing the supply and resetting once may work. Anything involving the pump, fan, sensors or ignition needs a Gas Safe registered engineer.
How do I fix low pressure on my boiler?
Use the filling loop to add water until the gauge reads 1 to 1.5 bar with the system cold, then close the filling loop fully. If you have to top up more than once or twice a year, there is a leak or a failing expansion vessel that needs finding.
Why does my boiler keep showing E1 after a reset?
If the same full code keeps returning, the underlying fault is still there. A reset only clears the lockout. Note the full code and how often it comes back, then book an engineer rather than resetting again.
Is it safe to leave my boiler showing E1?
Yes. When a fault code is showing, the boiler has shut down to protect itself and is not burning gas. It is safe to leave it off until an engineer arrives. If you smell gas at any point, call 0800 111 999.
When to call an engineer
If the full code is anything other than low pressure, or if low pressure keeps returning, it is time for an engineer. Our own Gas Safe registered engineers (registration 956889) repair Baxi, Potterton and all the major brands across Hertfordshire, Bedfordshire and Cambridgeshire from our Stevenage base, and we are rated 4.9 on Google. Book a boiler repair or call 01462 506374. We answer 24 hours a day, 7 days a week, and cover emergencies around the clock.
Need help today?
Call and speak to a person, any hour, any day of the year, or get a fixed price quote online.
Get a fixed price quote Call 01462 506 374Rather have an engineer look at it?
Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374