E1 on a boiler display is usually not a fault code on its own: on many Baxi and Potterton boilers with a two-digit display, a three-digit code such as E119 or E133 is shown as “E1” alternating with the last two digits. Watch the display for a few seconds to read the full code, because the meaning, and whether you can fix it yourself, depends entirely on those next two digits.

In short

  • Baxi and Potterton manuals explain that three-digit codes are shown as “E1” alternating with the rest, so E133 appears as “E1” then “33”.
  • The most common full codes are E119 (low water pressure) and E133 (gas supply or flame failure).
  • Low pressure is something you can usually fix yourself with the filling loop. Most other E1 codes need a Gas Safe registered engineer.
  • Reset the boiler once or twice at most. If the code returns, stop and book a repair.
  • If your display shows E1 on its own and never changes, check your own boiler’s user guide, because other makes use different code systems.
Ideal boiler installed by Vantage in a fitted cupboard, with copper pipework and a magnetic system filter
One of our boiler installations: an Ideal combi in a fitted cupboard with a magnetic system filter.

Why your boiler shows E1

Many Baxi and Potterton boilers, including models such as the Baxi Platinum Combi HE, the Baxi Duo-tec Combi HE and the Potterton Promax HE Plus range, have a small two-digit display. Their fault codes are either two or three digits long, always starting with E. The manufacturer’s installation manuals explain how they fit on the screen: a code such as E133 is displayed as “E1” alternating with “33”, while a two-digit code such as E20 is shown as “E” then “20”.

So when you glance at the boiler and see E1, you are usually seeing the first half of a longer code. Stand in front of the display for ten seconds and write down the digits that follow. That full code is what an engineer, or the user guide, will need, and it is the first thing we ask for when you book a boiler repair.

What the full E1 codes mean

These are the E1 codes listed in Baxi and Potterton installation manuals for the ranges above. The wording varies slightly from model to model, and newer Baxi boilers use some different numbers, so treat this as a guide and check your own manual.

Display showsFull codeMeaning in the manufacturer’s manualCan you do anything yourself?
E1 then 10E110Safety thermostat operated, an overheat of the primary waterCheck the pressure and bleed radiators, then reset once
E1 then 19E119Water pressure switch not operated. The pressure has fallen below about 0.5 barUsually yes, top up the pressure
E1 then 25E125Circulation fault in the primary circuit, or a pump problemCheck the pressure and bleed radiators
E1 then 30E130Flue NTC operated, a flue overheat. On some storage combis this code means the tank thermistor is out of placeNo, apart from one reset
E1 then 33E133Interruption of gas supply or flame failureCheck the gas supply and condensate pipe, then reset once
E1 then 60E160Fan or fan wiring faultNo
E1 then 93E193Pre-circulation faultCheck the pressure and bleed radiators

On newer Baxi models, low water pressure is shown as E118 and frequent flame loss as E128. If you have a boiler with a larger display that shows the whole code at once, you will not see E1 on its own.

Check these first

These are the safe checks any homeowner can make. They cover the most common E1 codes.

  1. Read the full code. Watch the display until you have seen the digits after E1. Write it down along with the boiler make and model from the label.
  2. Check the pressure gauge. With the system cold it should read roughly 1 to 1.5 bar. If it is below about 0.5 bar, you are almost certainly looking at E119. Top it up with the filling loop as your user guide shows, then close the filling loop fully.
  3. Check the gas supply. If the full code is E133, see whether your hob or other gas appliances work, and whether a prepayment meter has credit. If nothing lights, the problem is the supply, not the boiler.
  4. Look at the condensate pipe in cold weather. A frozen condensate pipe can stop the boiler lighting. Pour warm, not boiling, water over the frozen section outside at ground level.
  5. Bleed the radiators. For overheat and circulation codes such as E110, E125 and E193, trapped air or low pressure is sometimes the cause. Bleed any radiators that are cold at the top, then recheck the pressure.
  6. Reset once. Baxi’s manuals describe resetting by turning the selector to the reset position for at least five seconds on some models. Other models have a reset button. Your user guide shows which. If the code returns, stop.

What not to do

  • Do not keep resetting the boiler. If the same code keeps coming back, something needs fixing, and repeated resets can make it worse or lock the boiler out.
  • Do not remove the casing or touch the fan, gas valve, pump, circuit board, heat exchanger or flue. Under the Gas Safety (Installation and Use) Regulations 1998 only a Gas Safe registered engineer may work on a gas appliance.
  • Do not overfill when topping up. Stop at 1 to 1.5 bar, or the pressure relief valve may open.
  • If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows, do not use electrical switches, and turn the gas off at the meter if it is safe to do so.

Common causes behind E1 codes

CauseWhat you might noticeCan you fix it yourself?What the engineer does
Low system pressure (E119 or E118)Gauge below about 0.5 bar, no heating or hot waterYes, top up with the filling loopFinds the leak or recharges the expansion vessel if it keeps dropping
No gas or prepayment meter empty (E133)Hob will not light eitherYes, top up or contact your supplierNothing needed at the boiler
Frozen condensate pipe (E133)Cold weather, gurgling before shutdownYes, if the frozen section is outside and reachableClears the trap, insulates or reroutes the pipe
Air or sludge restricting flow (E110, E125, E193)Banging or kettling noises, cold spots on radiatorsPartly, by bleeding radiatorsChecks the pump, cleans the system, fits a filter
Failed pump (E125)Boiler fires then shuts off quickly, pipes stay coolNoTests and replaces the pump
Worn electrode or ignition parts (E133)Boiler clicks but does not light, or lights and goes outNoChecks electrodes, gas pressure and the gas valve
Fan fault (E160)Boiler will not start, no fan noiseNoTests the fan and its wiring, replaces as needed

What an engineer will check

A good engineer starts from the full code and the manufacturer’s fault-finding chart for your exact model, rather than swapping parts on a guess. Depending on the code, that means measuring the system pressure and the expansion vessel charge, checking the pump runs and water circulates, testing temperature sensors and the safety thermostat, checking gas pressure at the boiler inlet, inspecting the ignition and flame detection electrodes, checking the flue, and testing the fan and circuit board connections. After any gas-side repair, the engineer should check combustion with a flue gas analyser before leaving.

Our engineers repair Baxi and Potterton boilers alongside all the other major brands.

Repair or replace?

Most E1 codes lead to routine repairs: a pressure top-up, a pump, an electrode, a sensor. They are rarely, on their own, a reason to replace a boiler. Replacement makes more sense if the boiler is well past ten years old, needs a major part such as a heat exchanger or circuit board, or has needed several repairs in a short time. If you want to compare, you can get a fixed price online with our boiler quote tool.

What we charge to fix it

Our prices, before you ring

Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee£150 + VAT
£180 inc VAT
Evenings and weekends, first hour including the call-out£297.60
inc VAT
Overnight, first hour including the call-out£330
inc VAT
If a new boiler is the better answer, fittedfrom £2,780
inc VAT

The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.

Related codes

Frequently asked questions

What does E1 mean on a Baxi combi boiler?

On many Baxi combis, E1 is the first part of a three-digit code shown in two halves. Watch the display for the next two digits: E1 then 19 means E119, low water pressure, and E1 then 33 means E133, a gas supply or flame failure.

Can I fix the E1 error myself?

Sometimes. If the full code is E119 or E118, topping up the pressure with the filling loop usually clears it. If it is a gas supply problem, such as an empty prepayment meter, fixing the supply and resetting once may work. Anything involving the pump, fan, sensors or ignition needs a Gas Safe registered engineer.

How do I fix low pressure on my boiler?

Use the filling loop to add water until the gauge reads 1 to 1.5 bar with the system cold, then close the filling loop fully. If you have to top up more than once or twice a year, there is a leak or a failing expansion vessel that needs finding.

Why does my boiler keep showing E1 after a reset?

If the same full code keeps returning, the underlying fault is still there. A reset only clears the lockout. Note the full code and how often it comes back, then book an engineer rather than resetting again.

Is it safe to leave my boiler showing E1?

Yes. When a fault code is showing, the boiler has shut down to protect itself and is not burning gas. It is safe to leave it off until an engineer arrives. If you smell gas at any point, call 0800 111 999.

When to call an engineer

If the full code is anything other than low pressure, or if low pressure keeps returning, it is time for an engineer. Our own Gas Safe registered engineers (registration 956889) repair Baxi, Potterton and all the major brands across Hertfordshire, Bedfordshire and Cambridgeshire from our Stevenage base, and we are rated 4.9 on Google. Book a boiler repair or call 01462 506374. We answer 24 hours a day, 7 days a week, and cover emergencies around the clock.

Need help today?

Call and speak to a person, any hour, any day of the year, or get a fixed price quote online.

Get a fixed price quote Call 01462 506 374
Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.