Skip to main content

Vantage Plumbing and Heating

ESi Thermostat Not Working: Common Problems and Fixes

Hertfordshire, Bedfordshire & Cambridgeshire

Fully Stocked Vans12 Month Labour GuaranteeGas Safe Registered 956889

When an ESi thermostat stops working, the cause is usually simple: flat batteries, the thermostat switched to OFF (frost protection) or holiday mode, a wireless receiver that has lost its link to the thermostat, or a program set to a low temperature. Work through the checks below first, and if the thermostat is calling for heat but the boiler still does not respond, the fault is more likely to be in the wiring, the receiver or the boiler, which needs a heating engineer.

  • A blank screen on a battery model almost always means the batteries need replacing. Use fresh alkaline AA cells, not rechargeables.
  • If the slider is on OFF, the thermostat is in frost protection and only heats if the room drops to about 5°C.
  • Flashing red and green lights on a wireless receiver usually mean the link to the thermostat has been lost and it needs re-pairing.
  • A thermostat that turns the heating on when it is warm and off when it is cold is usually wired to the wrong terminal.
  • If the flame symbol shows but the boiler does nothing, the problem is downstream of the thermostat and needs an engineer.

How an ESi thermostat controls your heating

ESi Controls makes room thermostats and programmers that tell the boiler (or a zone valve) when to run the heating. When the room is colder than the set temperature, the thermostat closes a switch and the heating runs. When the room reaches temperature, the switch opens and the heating stops.

There are two main types:

  • Wired thermostats, connected by cable to the boiler or a wiring centre.
  • Wireless (RF) thermostats, such as the Atlantic (ESRTP4RFW), which send a radio signal to a separate receiver wired in near the boiler. The receiver does the switching.

Many ESi programmable thermostats, such as the Pacific (ESRTP4+) and the ESRTP5, run on batteries and show a flame symbol when calling for heat. That symbol is your most useful clue: it tells you whether the thermostat thinks the heating should be on. If it shows and nothing happens, the fault is further down the line, and our central heating repairs engineers can trace it.

Check these first

Work through these in order. None of them involves opening the boiler or touching mains wiring.

  1. Look at the screen. If it is blank or the low battery symbol is flashing, replace the batteries. ESi’s instructions for its battery models call for good quality alkaline cells (AA size on the Pacific and Atlantic), and the Atlantic’s instructions say not to mix old and new batteries or use rechargeables. On the Pacific, ESi says settings and the time are kept when you change the batteries.
  2. Check the slider or mode. On models with an AUTO, MAN and OFF slider, OFF puts the thermostat into frost protection. The screen shows a snowflake and the set temperature is 5°C, so the heating will not come on in a normal room. Move it to AUTO for your programme or MAN for a constant temperature.
  3. Check for holiday mode. Programmable models can hold a lower temperature for a set number of days. If holiday mode was left on, the heating will stay low until it ends or you cancel it.
  4. Check the programme temperatures. ESi’s programmable thermostats do not switch off in the usual sense. Each part of the day has a temperature, and “off” periods are normally set to something low, such as 7°C. If a period has been set low by mistake, the heating will not come on in that part of the day.
  5. Turn the temperature up. Raise the setting a few degrees above the room temperature. The flame symbol should appear. If it does, the thermostat is calling for heat.
  6. Check the boiler. Make sure it is switched on, has power at the fused spur, shows no fault code, and that the pressure gauge reads between about 1 and 1.5 bar when cold. If the boiler shows a fault, see our guide to a boiler not firing up.
  7. Check any programmer or timer. If you have a separate programmer for heating, it must also be in an on period, or set to constant, for the thermostat to have any effect.

What not to do

  • Do not take the thermostat or receiver off the wall to look at the wiring. Many are connected to 230V mains.
  • Do not open the boiler casing or wiring centre. Only a qualified engineer should work inside them.
  • If you smell gas at any point, call the National Gas Emergency Service on 0800 111 999, open windows and do not use electrical switches.

Common problems and what they mean

ProblemWhat you might noticeCan you fix it yourself?What the engineer does
Flat or weak batteriesBlank screen, flashing battery symbol, lost wireless linkYes, fit fresh alkaline batteriesNothing needed if this cures it
Slider on OFFSnowflake on screen, set temperature 5°CYes, move it to AUTO or MANNothing needed
Holiday mode or low programme temperatureHeating only comes on at some times, or not at allYes, cancel holiday mode or reset the programmeCan set up the programme with you
Wireless link lostReceiver lights flashing, boiler does not respondSometimes, by re-pairing using the manualChecks receiver power and wiring, re-pairs
Receiver in manual overrideGreen light on receiver, heating ignores the thermostatYes, press the override button to cancelNothing needed
Wired to the wrong terminalHeating runs when warm, stops when coldNoMoves the output to the correct terminal
Thermostat in a poor positionRoom too hot or too cold compared with the displayPartly, by moving heat sources awayRelocates it or adjusts the offset setting
Faulty thermostat or receiverNo response after all checksNoTests the switching, replaces the unit
Fault in the boiler or valvesFlame symbol shows but no heatNoTests the zone valve, wiring centre and boiler

Wireless thermostats: receiver lights and re-pairing

On the ESi Atlantic (ESRTP4RFW), the receiver near the boiler has two lights, and ESi’s installation instructions explain them:

  • No lights: the heating is off.
  • Red light only: the heating is on.
  • Green light only: the receiver is in manual override and the heating is off.
  • Red and green lights: the receiver is in manual override and the heating is on.
  • Flashing green: the receiver is in pairing mode, waiting for a thermostat.
  • Flashing red and green: the link between the receiver and the thermostat has been lost.

If the lights show a lost link, first fit fresh batteries in the thermostat, because weak batteries are a common cause. If the link does not return, ESi’s advice is to switch off the power to the receiver for around 10 minutes and then pair it again. The pairing button sequence is different on each model, so follow the installation instructions for yours or ESi’s support pages. If the receiver has no lights at all and never had power, it needs an engineer to check the supply to it.

ESi quotes a wireless range of about 30 metres in open space, and walls, floors and metal objects reduce it, so moving the thermostat can also break the link.

Temperature on the display does not match the room

ESi’s installation guidance says a room thermostat should be between 0.9 and 1.2 metres above the floor, away from draughts and away from heat sources such as radiators, lights, televisions and direct sunlight, and not on an outside wall. A thermostat in a hallway next to a front door, or above a radiator, will give misleading readings.

Some ESi thermostats also have installer settings, including a temperature offset to correct the reading and a switching setting that affects how often the boiler cycles. These sit behind a technical menu and are best changed by an engineer, because the wrong setting can make the heating short cycle or overshoot.

The heating turns on when it is warm and off when it is cold

ESi lists this as a known issue. It happens when the heating output has been connected to the normally closed terminal instead of the normally open one, which reverses how the thermostat works. It usually appears after a new installation and needs an engineer to correct the wiring.

Resetting an ESi thermostat

A factory reset wipes your programme, so it is rarely the first step, and the method varies by model. On the ESi Pacific (ESRTP4+), ESi’s user instructions say to hold the Next button and press the reset button to restore factory settings. Check the manual for your model first, and note down your programme times before you do it.

What an engineer will check

If the thermostat is working (the flame symbol shows when you turn it up) but the boiler still does not respond, a heating engineer will:

  • Check the switching at the thermostat or receiver with a meter.
  • Check the wiring centre and any zone valves. A stuck zone valve is a common reason the heating stays off even though the thermostat and boiler seem fine.
  • Check the programmer and any other controls in the circuit.
  • Check the boiler itself for faults, and that the pump runs when there is a demand.
  • Replace the thermostat or receiver if either has failed, or suggest a modern control if you want to upgrade.

If some radiators work and others stay cold, the thermostat is probably not the issue. Our guide to a radiator not heating up covers that.

Repair or replace?

A thermostat that has lost its programme, batteries or wireless link does not need replacing. If the unit itself has failed, a like-for-like ESi replacement keeps things simple, or you can upgrade: our smart thermostat installation page explains the options.

What we charge to fix it

Our prices, before you ring

Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee£150 + VAT
£180 inc VAT
Evenings and weekends, first hour including the call-out£297.60
inc VAT
Overnight, first hour including the call-out£330
inc VAT
If a new boiler is the better answer, fittedfrom £2,780
inc VAT

The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.

Frequently asked questions

Why is my ESi thermostat screen blank?

On battery models a blank screen almost always means the batteries are flat, so fit fresh alkaline cells. On mains-powered or boiler-powered models, a blank screen can mean there is no power to the thermostat, which needs an engineer. ESi also notes that the ESRTD3 display is designed to go to sleep to save power, even though the thermostat is still working.

What does the snowflake mean on my ESi thermostat?

The snowflake shows frost protection. On models with a slider, moving it to OFF puts the thermostat into this mode with a set temperature of 5°C, so the heating only runs to stop the house getting dangerously cold. Move the slider back to AUTO or MAN to heat normally.

Why does my ESi thermostat show a time with an h?

That appears when you have used the plus or minus buttons to override the programme temporarily. ESi explains that the display alternates between the temperature and the hours left until the next programmed period, where h means hours. It is normal and clears when the next period starts.

Can one ESi receiver work with two thermostats?

ESi says its wireless receivers are designed to talk to one room thermostat, unless the product’s documentation says otherwise. If you want separate control of two areas, you normally need a zoned system with a receiver and valve for each zone.

When to call an engineer

If you have changed the batteries, checked the mode, programme and holiday settings, and tried re-pairing a wireless receiver, but the heating still will not come on, the fault is in the wiring, a valve, the receiver or the boiler. Book our central heating repairs team on 01462 506374. The phone is answered 24 hours a day, 7 days a week, and we cover Hertfordshire, Bedfordshire and Cambridgeshire.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.