A faulty diverter valve on a combi boiler usually shows up as heating but no hot water, hot water but no heating, lukewarm water at the taps, or radiators warming up whenever you run a hot tap. The valve sits inside the boiler, so beyond a few safe checks on the controls and pressure, it needs a Gas Safe registered engineer to test it and repair or replace the motor or the valve.

  • The diverter valve sends a combi boiler’s heat either to the radiators or to your hot water.
  • Classic signs: radiators get warm when you run a hot tap, hot water is only lukewarm, or only one of heating and hot water works.
  • Common causes are a failed motor (actuator), a valve seized by scale or sludge, or worn internal seals.
  • Check the thermostat, timer, boiler pressure and tap flow first, and reset once. Do not open the boiler.
  • Most faults are repaired by replacing the motor head or the valve, not the boiler.
Ideal boiler installed by Vantage in a fitted cupboard, with copper pipework and a magnetic system filter
One of our boiler installations: an Ideal combi in a fitted cupboard with a magnetic system filter.

New boiler?

Get an instant estimate for a new boiler

Answer a few questions about your home online and see your estimate straight away, fitted by our own engineers.

Instant boiler estimateOr call 01462 506 374

What a diverter valve does

A combi boiler heats your radiators and your hot water with the same burner and heat exchanger, but it cannot do both at full output at once. The diverter valve decides where the heat goes. It is a three-way valve inside the boiler with one inlet and two outlets: one to the central heating circuit, and one to a small plate heat exchanger that heats the water going to your taps and shower.

Vaillant describes it as a mechanism that opens or closes to direct hot water either to the radiators or to the taps and showers. It gives priority to hot water. If the heating is on and someone turns on the shower, the valve switches to the hot water side until the tap closes, then switches back.

Most modern boilers use a motorised valve, where a small electric motor, often called the actuator or motor head, clips onto a valve body and moves a spindle inside it. Some older boilers used a hydraulic valve moved by water pressure acting on a rubber diaphragm.

System and regular boilers that feed a hot water cylinder usually share heat between the radiators and cylinder with motorised zone valves in the pipework outside the boiler, although some system boilers have a diverter valve built in for the cylinder. This guide concentrates on combi boilers, where diverter valve faults are most common.

Symptoms of a faulty diverter valve

What you noticeWhat is probably happening
Radiators warm up when you run a hot tap, even with the heating offThe valve is stuck in the heating position, so the heat meant for your tap goes to the radiators
Hot water but no heatingThe valve is stuck on the hot water side, or the motor cannot move it back
Heating works but no hot water, or it is only lukewarmThe valve is not moving fully to hot water, or is sitting part way
Hot water only when the heating is onThe valve is stuck part way, letting heat reach both sides
Hot water runs hot then coldThe valve is sticking or drifting, though this also has other causes
Water dripping inside or under the boiler, pressure droppingWorn seals on the valve spindle or body are leaking
An error code about circulation or temperatureSome boilers show a fault when water is not moving where the board expects it

None of these symptoms prove it is the diverter valve. A scaled plate heat exchanger, a faulty flow sensor, a thermostat or a timer fault can all look similar, which is why the engineer tests before replacing parts. Our guide to no hot water but the heating works covers the wider picture.

Check these first

These checks are safe for a homeowner and rule out the simple causes.

  1. Check the controls. Make sure the timer or programmer and the room thermostat are asking for heat. Turn the thermostat up a few degrees. A boiler that is not being asked for heating will only ever give you hot water.
  2. Check the boiler pressure. With the heating cold, the gauge should read the pressure your user guide recommends, usually between 1 and 1.5 bar. If it is low, repressurise with the filling loop if your user guide allows it, and see our guide to a boiler that keeps losing pressure if it keeps dropping.
  3. Open the hot tap fully. A combi only switches to hot water when it senses enough flow. A barely open tap, or a blocked tap aerator or shower head, may not trigger it.
  4. Test it with the heating off. Turn the heating off at the programmer, run a hot tap for a few minutes, and feel whether the radiators start warming. If they do, the valve is almost certainly stuck.
  5. Note any error code. Write down what the display shows. It helps the engineer and may point elsewhere.
  6. Reset once. Use the reset button as your user guide describes. If nothing changes, leave it and book a boiler repair.

What not to do

  • Do not remove the boiler casing or try to free, tap or replace the diverter valve. It sits in the water circuit next to gas and electrical components, and under the Gas Safety (Installation and Use) Regulations 1998 only a Gas Safe registered engineer may work on a gas appliance.
  • Do not keep resetting the boiler to make it switch between heating and hot water.
  • If water is leaking from the boiler, turn the boiler off at the fused spur and put a container underneath. Water and electrics do not mix.
  • If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows, do not use electrical switches, and turn off the gas at the meter if it is safe to do so.

Common causes of a faulty diverter valve

CauseWhat you might noticeCan you fix it yourself?What the engineer does
Failed motor or actuatorValve stuck in one position, no sound of it movingNoTests the supply from the board and replaces the motor head
Valve seized by scale or sludgeStuck on heating or hot water, often after a quiet summerNoFrees the valve or replaces the cartridge or body, and looks at water quality
Worn diaphragm or internal sealsLukewarm water, heat reaching both sides at onceNoReplaces the internal parts or the valve
Leaking spindle or body sealsDrips inside the case, pressure droppingNoReplaces the seals or valve and checks for water damage to electrics
Wiring or main board faultMotor works when tested directly but not in normal useNoChecks the connections and the board’s output
Something else that mimics itSymptoms fit, but the valve moves correctlyControls onlyTests the flow sensor, plate heat exchanger, thermostat and timer

Two things make diverter valves fail more often. The first is dirty system water: sludge and magnetite from corroding radiators collect in moving parts. The second is hard water. Across most of Hertfordshire the water is hard, and scale builds up on the hot water side of a combi, particularly the plate heat exchanger and any parts in contact with the hot water.

What an engineer will check

  1. The fault history and symptoms. When the problem started, what works and what does not, and any stored error codes.
  2. Controls. That the thermostat, programmer and wiring are asking the boiler for the right thing.
  3. Valve movement. Whether the motor drives the valve fully from heating to hot water and back, and whether the valve body moves freely with the motor removed.
  4. The electrical side. Whether the board is sending the signal to switch, and whether the motor responds.
  5. The hot water path. The flow sensor, the plate heat exchanger and the hot water temperature sensor, to rule out a lookalike fault.
  6. Leaks and water quality. Signs of weeping around the valve, the condition of the system water and whether a magnetic filter is fitted.
  7. A full test. Heating and hot water both run and switch correctly before the engineer leaves.

Repair or replace?

A diverter valve fault on its own is almost always a repair. On many boilers the motor head can be replaced separately from the valve body, which is a quicker job. If the valve itself is seized or leaking, the valve or its internal cartridge is replaced, which means draining down part of the system.

It is worth thinking about replacement only if the boiler is old, parts for that model are becoming hard to get, or the valve is one of several faults stacking up. Our repair or replace guide explains how we weigh that up.

What it costs with Vantage

In normal working hours there is no call-out fee. Gas faults start with a fixed-price Gas Safe diagnostic visit, and if we can fix it on the same visit, part of that diagnostic charge comes off the repair. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive.

A motor head is usually the less expensive fix, while a complete valve costs more because of the part and the extra time to drain and refill. We repair and service all the major brands, our vans are fully stocked, and our repairs carry a 12 month labour guarantee.

Preventing diverter valve problems

  • Keep the system water clean. A magnetic system filter and the right level of inhibitor protect moving parts. If the system is badly sludged, a power flush may be worth it before replacing parts that will only clog again.
  • Deal with hard water. A scale reducer on the boiler’s cold feed, or a water softener for the whole house, slows scale on the hot water side.
  • Service the boiler every year. An engineer will spot a valve that is slow to move before it sticks.

Frequently asked questions

Can a diverter valve be unstuck without replacing it?

Sometimes. An engineer can occasionally free a sticking valve, but if it has seized once from scale or sludge it usually sticks again, so replacing the valve or cartridge is the more reliable fix. It is not a job for a homeowner.

Why do my radiators get hot when I run the hot tap?

On a combi boiler that almost always means the diverter valve is stuck in the heating position. The boiler fires because it senses the tap is open, but the heat goes to the radiators instead of the hot water.

Can I still use my boiler with a faulty diverter valve?

Usually you can use whichever side still works, as long as there is no leak and no error code. If water is dripping from the boiler or the pressure keeps falling, turn it off and book a repair.

Do system boilers have a diverter valve?

Some do, built in to share heat between the radiators and a hot water cylinder. Many system and regular boiler setups use separate motorised zone valves in the pipework instead, which can fail in similar ways.

How long does a diverter valve repair take?

A motor head swap is quick once the fault is confirmed. Replacing the valve body takes longer because the boiler has to be isolated and partly drained, then refilled, bled and tested.

When to call an engineer

If your combi is only giving you heating or only hot water, or the radiators warm up when you run a tap, the diverter valve is the first thing we test. Our Gas Safe registered engineers (registration 956889) can find the cause and fix it, often on the first visit. See our boiler repair service or call 01462 506374, answered 24 hours a day, 7 days a week.

Need help today?

Call and speak to a person, any hour, any day of the year, or get a fixed price quote online.

Get a fixed price quote Call 01462 506 374
Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.