Flashing Blue Light on a Boiler: What It Means and What to Do
Hertfordshire, Bedfordshire & Cambridgeshire
A flashing blue light on a boiler, most often a Worcester Bosch Greenstar, means the boiler has detected a fault and stopped or locked out, and the code on the display tells you which fault it is. A steady blue light is normal, so write down the code, try the few safe checks below and one reset, and if the light keeps flashing, you need a Gas Safe registered engineer.
- On Worcester Bosch Greenstar boilers, the blue light is the operation and fault light. Steady means working normally, flashing means a fault.
- The display shows a code, often two characters plus a three-digit number, such as EA and 227. That code is the most useful thing to note.
- Low pressure, a frozen condensate pipe and a gas supply problem are the causes you can often check yourself.
- Press reset once. If the blue light is still flashing, or the fault returns, stop and call an engineer.
- Never take the boiler casing off. Everything inside needs a Gas Safe engineer.

What the blue light means
Worcester Bosch fits a blue indicator light to many Greenstar boilers, including the Greenstar i and Greenstar Si Compact ranges. Worcester’s user instructions describe it this way:
- Steady blue: the boiler is working. On the Greenstar i it lights when there is a demand for heating or hot water. On the Si Compact it is on when the boiler is in an operational mode.
- Blue off: on these models, it is normal for the light to go out when there is no demand and the boiler is idle.
- Flashing blue: the boiler has detected a fault. A fault code appears on the display, and on some models the reset button also flashes.
Some owners ask their installer to turn off the steady demand light because it is bright at night. Worcester notes that even when that is done, the light still flashes to warn you of a fault.
Other makes use different lights and symbols. If your boiler is not a Worcester Bosch, check the user guide for your model before assuming the blue light means the same thing. Whatever the make, our boiler repair engineers can diagnose the fault.
Step one: read the code
When the blue light is flashing, look at the display. On Greenstar i, Si Compact and CDi Compact boilers, faults are shown as a two-character display code, often with a three-digit cause code, for example EA with 227. Write down both, exactly as they appear. That tells you, and the engineer, far more than the flashing light alone.
| Display code | Common cause codes | What it means | Can you do anything? |
|---|---|---|---|
| EA | 227, 229 | The boiler has not detected a flame, or the flame was lost | Yes, check the gas supply and the condensate pipe |
| A1 | 281 | Pump problem, often air in the system or low pressure | Yes, check and top up the pressure if your guide allows |
| E9 | 224, 276 and others | Overheat protection has operated | Check the pressure and radiator valves, then call an engineer |
| C6 | 215, 216 | Fan speed or airflow problem | Only check the flue outside is clear |
| E2 | 222, 223 | Flow temperature sensor fault | Engineer only |
| F0 | Many | Internal electronics fault | One reset, then engineer |
| F7 | 228 | Flame signal seen when there should be no flame | Engineer only |
| Fd | 231 | Power was interrupted while the boiler was locked out | Press reset |
For a full list, see our guide to Worcester Bosch fault codes.
Check these first
These checks are safe for a homeowner. None of them means opening the boiler.
- Note the code and cause code before you do anything else.
- Check the pressure gauge. With the system cold, it should normally read between about 1 and 1.5 bar. Worcester’s user instructions say that if it reads below 1 bar, the system needs topping up. If your user guide shows how to use the filling loop, top it up slowly and close both valves afterwards. If you are not sure, leave it to an engineer. If it drops again within days, there is a leak or a faulty part to find.
- Check the gas supply. Does the hob light? If you have a prepayment meter, check it has credit. If other gas appliances are also off, the problem is the supply, not the boiler.
- Check the condensate pipe in cold weather. If the white or grey plastic pipe from the boiler to an outside drain has frozen, the boiler will shut down, usually with an EA code on Greenstar boilers. Thaw it with warm (not boiling) water, as our frozen condensate pipe guide shows.
- Check the power. Make sure the fused spur is on and the fuse has not blown. A power cut during a lockout can show as Fd.
- Check the flue outside. Make sure nothing is blocking the flue terminal, such as a bag, a nest or a bush grown over it. Do not touch or remove the terminal.
- Press reset once. Worcester’s instructions say to press it briefly once. If the reset works, the blue light stops flashing and the boiler goes back to normal operation.
What not to do
- Do not keep pressing reset. If it has not cleared after one attempt, repeated resets will not fix the cause and can make some faults worse.
- Do not remove the boiler casing or touch the gas valve, fan, PCB, electrodes, heat exchanger or flue. By law only a Gas Safe registered engineer can work on a gas appliance.
- Do not ignore a boiler that locks out every few days. The fault is still there even if a reset gets it going.
- If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows, do not use electrical switches and turn the gas off at the meter if it is safe to do so.
Common causes of a flashing blue light
| Cause | What you might notice | Can you fix it yourself? | What the engineer does |
|---|---|---|---|
| Low system pressure | Gauge below 1 bar, A1 or similar code | Yes, top up with the filling loop if your guide allows | Finds the leak, checks the expansion vessel and pressure relief valve |
| No gas or low gas pressure | EA, hob will not light, prepay meter empty | Yes, top up or contact your supplier | Tests the gas pressure at the boiler |
| Frozen or blocked condensate pipe | EA in cold weather, gurgling noise | Yes, if the pipe is reachable at ground level | Reroutes, insulates or upsizes the pipe |
| Air or sludge in the system | A1 or E9, cold spots on radiators, noisy boiler | Bleed radiators only | Vents the boiler, cleans the system, fits a magnetic filter |
| Worn ignition or flame sensing electrode | EA that keeps coming back | No | Inspects, cleans or replaces the electrode |
| Failed pump | A1 or E9, boiler hot but radiators cold | No | Frees or replaces the pump |
| Fan or flue fault | C6 | Only check the flue terminal outside | Checks the fan, its wiring and the flue |
| Failed sensor or PCB fault | E2, F0 or other internal codes | No | Tests components and replaces the faulty part |
What an engineer will check
A Gas Safe engineer will start with the code and cause code, then look at the boiler’s fault history. Depending on the fault, they will:
- Test the gas pressure at the boiler inlet to check it is getting enough gas.
- Inspect and clean the condensate trap and pipe.
- Check the ignition and flame sensing electrodes and their leads.
- Check the pump, the pressure sensor and the expansion vessel.
- Test the fan, sensors and wiring with a meter.
- Check the flue for blockages and correct fitting.
- Carry out a combustion analysis once the boiler is running again.
Repair or replace?
Most faults that bring on a flashing blue light are repairable, such as a frozen condensate pipe, low pressure, a worn electrode or a failed sensor. Replacement is worth discussing when the boiler is old, the repair involves an expensive part such as the heat exchanger, or the same faults keep returning. An engineer can give you an honest view once the fault is diagnosed.
We repair and service all the major brands, including Worcester Bosch.
What we charge to fix it
Our prices, before you ring
| Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee | £150 + VAT £180 inc VAT |
| Evenings and weekends, first hour including the call-out | £297.60 inc VAT |
| Overnight, first hour including the call-out | £330 inc VAT |
| If a new boiler is the better answer, fitted | from £2,780 inc VAT |
The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.
Related codes
- Worcester Bosch EA fault code: the boiler has not detected a flame.
- Worcester Bosch A1 fault code: pump and pressure problems.
- Worcester Bosch E9 fault code: overheat protection.
Frequently asked questions
Is a flashing blue light on my boiler dangerous?
The flashing light itself means the boiler has protected itself by shutting down, which is what it is designed to do. It is not usually dangerous to leave it off. If you can smell gas, or see scorching or soot around the boiler, switch it off and call the National Gas Emergency Service on 0800 111 999.
Why is my Worcester boiler flashing blue with no code?
Look closely at the display, as some codes scroll or alternate with the temperature. On some older Greenstar models the fault is shown by the flashing light and reset button without a detailed code. In either case, try one reset, and if it keeps flashing, call an engineer and describe exactly what you see.
Should the blue light on my boiler be on all the time?
No. On many Greenstar boilers, the steady blue light only shows when the boiler is running for heating or hot water, and it goes out when there is no demand. Installers can also turn off the steady light, while leaving the flashing fault warning working.
How many times can I reset my boiler?
Press reset once, as Worcester’s instructions describe. If the fault does not clear, or it comes back soon after, further resets will not fix the cause. Book a Gas Safe engineer instead.
Why does the blue light flash only in cold weather?
The most likely reason is a frozen condensate pipe, which usually shows as an EA code on Greenstar boilers. Thaw the pipe with warm water, then press reset once. If it happens every winter, an engineer can reroute or insulate the pipe.
When to call an engineer
If the blue light is still flashing after you have checked the pressure, gas supply, condensate pipe and power, and pressed reset once, the fault is inside the boiler and needs a Gas Safe engineer. Book our boiler repair team on 01462 506374. We answer the phone 24 hours a day, 7 days a week, and cover Hertfordshire, Bedfordshire and Cambridgeshire. Our Gas Safe registration number is 956889.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.