Glow-worm F22 Fault Code Explained
Hertfordshire, Bedfordshire & Cambridgeshire
An F22 fault on a Glow-worm boiler means system water pressure has dropped too low and the boiler has shut down to protect itself.
This is one you can usually fix yourself in about five minutes.
What F22 actually means
The boiler needs a minimum amount of water in the system to run safely. Below roughly 0.5 bar it stops firing rather than risk running the heat exchanger dry.
So it is not really a fault. It is the boiler telling you the system has lost water.
What you can safely check yourself
Check the pressure gauge. It should read 1 to 1.5 bar when cold. If it is near zero, repressurise using the filling loop until it reaches 1.5 bar, then reset.
If it drops again within days you have a leak and it needs finding rather than topping up.
When to stop, and why
If the pressure keeps dropping, stop topping it up. A sealed system holds pressure for months. Repeatedly refilling a leaking system introduces oxygenated water and accelerates corrosion, turning a small repair into a bigger one.
What causes it beyond the simple checks
A leaking radiator valve, a pressure relief valve discharging outside, corroded pipework under the floor, or a failed expansion vessel. We can trace a hidden loss with leak detection without lifting your floors.
How Vantage can help
We are Gas Safe registered and cover Hertfordshire, Bedfordshire and Cambridgeshire, with an emergency line answered 24 hours a day.
Call us on 01462 506374. See also boiler repair.
Frequently asked questions
How often should I top up the pressure?
Once or twice a year is normal. More than that means a leak.
What pressure should it be?
1 to 1.5 bar when the system is cold.
Is it expensive?
If it just needs repressurising it costs nothing. A leak or a failed expansion vessel needs an engineer.
Related fault codes
Other Glow-worm codes: Glow-worm F28
The same problem on other makes (low water pressure): Vaillant F22 · Ideal F1 · Baxi and Potterton E119
See also our guide to boiler keeps losing pressure, the full boiler advice section, and boiler repair.
In Glow-worm’s own words
Glow-worm’s trade fault-finding list gives F.22 as “Safety switch-off: Low water pressure in the boiler”.
The wording is deliberate. This is a safety switch-off, not a breakdown. The boiler has stopped itself rather than run the heat exchanger with too little water in it.
When to call an engineer
Anything past the free checks above needs a Gas Safe engineer with the right test kit. Ring Vantage on 01462 506374, any hour, any day of the year. You will get an honest arrival time rather than a comforting one, and the price before the work.
Need help today?
Call and speak to a person, any hour, any day of the year, or get a fixed price quote online.
Get a fixed price quote Call 01462 506 374What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.