Hot Water but No Heating: Causes and What to Check
Hertfordshire, Bedfordshire & Cambridgeshire
If you have hot water but no heating, the boiler itself is usually working, so the problem is almost always in what tells it to heat the radiators or in the valve that sends heat to them. Start with the controls (programmer, room thermostat and the boiler’s heating setting); if those are right, the usual culprit is a stuck diverter valve on a combi or a failed motorised zone valve on a system with a hot water cylinder.
- Check the heating is switched on at the programmer and the boiler, and the thermostat is set above room temperature.
- Flat batteries or a lost connection on a wireless or smart thermostat are a very common cause.
- On a combi, a diverter valve stuck in the hot water position gives exactly this symptom.
- On a system with a cylinder, a failed zone valve or mid-position valve is the usual cause.
- Valves, pumps and anything inside the boiler need a heating engineer.
Why you can have hot water but no heating
Your boiler heats water, and then something decides where that heat goes: to your taps (or a hot water cylinder) or to your radiators. If hot water works, the boiler is lighting, the gas supply is fine and the burner is producing heat. What has failed is the call for heating, or the route to the radiators, which is the kind of fault our central heating repairs team diagnoses and repairs.
Which part to suspect depends on your system.
- Combi boiler (no hot water cylinder): inside the boiler, a diverter valve switches the heat between the hot water side and the heating side. Hot water always takes priority.
- System or regular boiler with a cylinder: outside the boiler, motorised valves open to send heat to the heating circuit, the cylinder or both. On an S-plan system there are two separate two-port valves. On a Y-plan system there is one three-port mid-position valve.
- Older gravity hot water systems: some older homes heat the cylinder by gravity, with a pump only for the radiators. If that pump fails, you keep hot water but lose the heating.
Check these first
You can safely work through these before calling anyone.
- Check the programmer or timer. Make sure the heating is switched on, not set to hot water only, and that the clock and heating times are right. Try the override or boost button.
- Check the room thermostat. Turn it up a few degrees above the current room temperature. You should hear the boiler respond within a few minutes.
- Check the thermostat batteries and connection. Wireless and smart thermostats stop calling for heat when the batteries run low or they lose their connection to the receiver or hub.
- Check the boiler’s heating setting. Many boilers have a heating on or off setting, a summer mode or a heating temperature control. Make sure heating is enabled and the heating temperature is not turned right down. Glow-worm suggests a flow temperature between 60 and 70 degrees for radiators to warm properly.
- Check the pressure gauge. Most sealed systems want around 1 to 1.5 bar when cold. If it is low, top up with the filling loop if your user guide allows. If it keeps dropping, see our guide to a boiler that keeps losing pressure.
- Check the radiator valves. Make sure thermostatic radiator valves are turned up. After the summer, the pin on a TRV can stick. With the head removed, the pin should move in and out freely when pressed gently.
- Feel the radiators. If they are warm at the bottom but cold at the top, there is air. Bleeding the radiators should sort it, then recheck the pressure.
What not to do
- Do not remove the boiler casing or try to free the diverter valve. Everything inside the case is a job for a Gas Safe registered engineer.
- Do not take the motor head off a zone valve unless you know how to isolate it. It is connected to mains voltage wiring.
- Do not keep resetting the boiler if it shows a fault code. Note the code and call an engineer.
- If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows, do not use switches and turn off the gas at the meter if it is safe to do so.
Common causes
| Cause | What you might notice | Can you fix it yourself? | What the engineer does |
|---|---|---|---|
| Heating not switched on or wrong programme | Boiler never fires for heating | Yes, check the programmer | Nothing needed |
| Thermostat batteries, setting or connection | Thermostat blank, or boiler does not respond when turned up | Usually: new batteries, re-pair the thermostat | Tests the wiring and replaces a faulty thermostat or receiver |
| Heating turned off at the boiler or summer mode on | Hot water fine, heating never starts | Yes, check the boiler settings | Nothing needed |
| Diverter valve stuck (combi) | Hot water works, radiators stay cold, sometimes warm radiators only when a hot tap runs | No | Replaces the valve cartridge, motor or whole valve |
| Zone valve or mid-position valve failed (system with cylinder) | Hot water works, heating pipe from the valve stays cold | No | Tests and replaces the valve motor, microswitch or valve body |
| Pump failed (gravity hot water systems) | Hot water fine, radiators cold, pump quiet or humming | No | Frees or replaces the pump |
| Air in the system | Radiators cold at the top, gurgling | Yes, bleed the radiators | Vents the system if bleeding does not work |
| Stuck TRV pins or closed valves | One or two radiators cold | Often, gently free the pin | Replaces the valve |
| Sludge blockage | Radiators cold at the bottom, several affected | No | Cleans the system and fits a filter |
| Wiring centre or programmer fault | Controls look right but nothing happens | No | Tests the wiring and replaces faulty controls |
Combi boilers: the diverter valve
When you turn on a hot tap, the diverter valve moves to send heat to the hot water side. When the tap closes, it should move back to the heating side. If it sticks in the hot water position, you get hot water but the radiators never heat up. If it sticks part way, you may find the radiators warm up only while a hot tap is running, or the hot water is lukewarm. Hard water and sludge both make diverter valves more likely to stick.
The diverter valve is inside the boiler, so this is always a job for a Gas Safe registered engineer. On many boilers only the motor or internal cartridge needs replacing.
Systems with a hot water cylinder: zone valves
On a system with a cylinder, the heating and hot water are controlled by motorised valves, usually in the airing cupboard near the cylinder. When the thermostat calls for heat, the heating valve opens and a switch inside it tells the boiler and pump to run. If the valve motor fails, the valve stays shut and the radiators stay cold, even though the cylinder still heats.
A common sign is that the pipe leaving the heating valve stays cold while the pipe going in is hot. An engineer can test the motor, the internal switch and the wiring, and usually replaces only the motor head.
When only some radiators are cold
If the heating comes on but some radiators stay cold, the cause is different. It is usually air, sludge, a stuck radiator valve or a system that needs balancing. Our guide to a radiator not heating up covers this. And if you have the opposite problem, see our guide to no hot water but the heating works.
What an engineer will check
- The controls and wiring, to confirm the heating demand is reaching the boiler.
- The diverter valve on a combi, or the zone valves on a system with a cylinder.
- The pump and the flow through the system.
- The system pressure and expansion vessel.
- Any fault codes and the boiler’s operation on heating.
- The condition of the system water, for signs of sludge or scale.
Our engineers carry common diverter valve parts, zone valve motors and pumps on the van.
Repair or replace?
Diverter valves, zone valve motors and pumps are all repairable parts, and replacing one is almost always better value than replacing the boiler. It is worth considering a new boiler only if the boiler is old, has repeated faults or parts are no longer available. Our boiler repair engineers will tell you honestly which makes sense.
What we charge to fix it
Our prices, before you ring
| Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee | £150 + VAT £180 inc VAT |
| Evenings and weekends, first hour including the call-out | £297.60 inc VAT |
| Overnight, first hour including the call-out | £330 inc VAT |
| If a new boiler is the better answer, fitted | from £2,780 inc VAT |
The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.
Frequently asked questions
Why is my hot water working but not my central heating?
Because the boiler is working, the fault is usually in the heating controls or the valve that sends heat to the radiators. On a combi that is often the diverter valve. On a system with a hot water cylinder it is usually a motorised zone valve.
Can a thermostat cause no heating but hot water?
Yes. If the room thermostat is set too low, has flat batteries or has lost its connection to the boiler, the heating is never called for, while the hot water carries on as normal. It is one of the most common causes and the easiest to fix.
How do I know if my diverter valve is broken?
Typical signs on a combi are hot water but cold radiators, radiators that only warm up while a hot tap is running, or lukewarm hot water. An engineer can confirm it by testing the valve, as other faults can look similar.
Is it safe to use my hot water if the heating is not working?
Usually, yes. If the boiler shows no fault code and there is no smell of gas, you can keep using the hot water until the heating is repaired. If the boiler is making unusual noises or keeps locking out, stop and get it checked.
Why is my boiler running but the radiators are cold?
On a combi, the heat may be going to the hot water side because the diverter valve is stuck. On other systems, a closed zone valve, a failed pump or a blockage can stop the heat reaching the radiators. Air in the radiators causes cold tops rather than completely cold radiators.
When to call an engineer
If the controls are set correctly and the radiators still stay cold, the fault is almost certainly a valve, pump or wiring problem that needs an engineer. Our phone is answered 24 hours a day, 7 days a week. See our central heating repairs page or call 01462 506374.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.