How to Clean a Magnetic Boiler Filter, Step by Step
Hertfordshire, Bedfordshire & Cambridgeshire
To clean a magnetic boiler filter, turn the heating off, close the filter’s isolating valves, release the pressure, take off the cap and slide the magnet out of its sleeve so the black sludge falls away, then refit it, open the valves, bleed out the air and check the boiler pressure. Most filters should be cleaned at least once a year, usually as part of the boiler service.
In short
- A magnetic filter catches magnetite, the black iron sludge that forms inside radiators and pipes.
- Manufacturers recommend cleaning it at least once a year, and more often on a dirty system.
- The steps are: heating off, isolate, release pressure, remove and clean the magnet, refit, open the valves, bleed, repressurise.
- Always follow the instructions for your filter, because designs differ.
- After cleaning, the system needs the right level of inhibitor to stop sludge forming again.
Power flush price
Cold radiators or sludge? See your fixed price now
Tell us how many radiators you have and what your system is, and you get a fixed power flush price straight away, online.
What a magnetic filter does
Inside every central heating system, water is in contact with steel radiators, copper pipes and the boiler’s heat exchanger. Over time the steel corrodes and forms magnetite, a fine black iron oxide. It settles in radiators, blocks narrow passages in the boiler and wears out the pump.
A magnetic filter sits on the heating pipework, usually on the return pipe just under the boiler. As water passes through, a strong magnet inside a plastic or metal sleeve pulls the magnetite out of the flow. Some filters also have a mesh or a separate chamber to catch non-magnetic debris. Every time you clean the magnet, you are removing sludge that would otherwise be circulating round the house.
Filters are sold under several names, but most work the same way. Every new boiler package we fit includes a magnetic system filter, because it protects the boiler’s heat exchanger for years.
How often to clean it
Most manufacturers recommend a clean at least once a year. On a new boiler, a good engineer cleans the filter as part of the annual boiler service, so if yours is serviced every year, it may already be done.
Clean it more often if:
- the system was dirty before the filter went on, for example an older system that was not flushed;
- you see a lot of sludge each time you clean it;
- radiators are cold at the bottom or you get black water when you bleed them.
A filter that fills with sludge every few months is a sign the system needs more than a filter. See power flushing below.
Before you start
You will need an old towel, a small bucket or bowl, a cloth, the filter’s user instructions (often on the manufacturer’s website), and sometimes a spanner or the filter’s cap tool. Know how to repressurise your boiler with the filling loop, as described in the boiler’s user guide, because you will usually lose a little pressure.
Stay safe
- Only work on the filter itself. Never remove the boiler casing or touch anything inside the boiler. That is work for a Gas Safe registered engineer.
- The filter and pipes can be hot. Let the system cool first.
- The magnet is strong. Keep it away from phones, bank cards and anyone with a pacemaker, as filter manufacturers warn.
- Do not force a seized cap or valve. If it will not move with normal effort, stop and call an engineer.
How to clean a magnetic filter: step by step
These are the general steps. Your filter may differ, so check its instructions.
- Turn off the heating and let it cool. Switch the boiler off or set it so it will not fire. Some filters have a bypass setting that lets you work with the system running, but cool is safer.
- Put a towel under the filter and have a bowl ready. A small amount of dirty water will come out.
- Close the isolating valves. Most filters have valves on the inlet and outlet, or a single rotating head that closes both. Turn them to the closed or service position.
- Release the pressure. Open the small air vent or bleed screw on top of the filter slowly, with a cloth over it, until the hissing stops. The water left inside is no longer under pressure.
- Remove the cap or magnet housing. Unscrew the top cap (or bottom cap on some designs). Some filters let you drain a little water through a drain valve at the bottom first, which flushes out loose sludge.
- Pull the magnet out of its sleeve. The magnetite clings to the outside of the sleeve. When the magnet is withdrawn, most of the sludge drops off into the bowl. Wipe the sleeve clean.
- Check the seals. Look at the O-ring on the cap. It should be clean, seated and undamaged. A little silicone grease, if the manufacturer recommends it, helps it seal.
- Refit everything. Put the magnet back in its sleeve, refit the cap and tighten it by hand, or as the instructions say. Do not overtighten plastic caps.
- Open the valves slowly and watch for drips around the cap.
- Bleed the air from the filter’s vent until water comes out, then close it.
- Check the boiler pressure. On a combi or system boiler, top it up with the filling loop to the level in the user guide, usually shown on the gauge.
- Turn the heating back on and check the filter and the joints again once the system is warm.
What the sludge tells you
| What you find | What it means | What to do |
|---|---|---|
| A light grey film | Normal. The filter is doing its job | Carry on cleaning yearly |
| A thick black coat, every time | Heavy corrosion in the system | Check inhibitor strength; consider a system clean |
| Orange or brown debris | Rust from steel parts, sometimes where fresh water keeps entering | Look for leaks and frequent top-ups |
| Grit or scale | Limescale or debris, common in hard water areas | An engineer can check the system water |
| Almost nothing after years | Either a very clean system or the filter is not in the flow | Ask your engineer to check its position and valves |
Top up the inhibitor
Cleaning the filter removes sludge but does not stop it forming. That is the job of inhibitor, a chemical added to the heating water that slows corrosion. Filter manufacturers advise re-dosing the system with inhibitor after cleaning or maintenance, and many filters have a port for adding it.
If you are not confident adding inhibitor, leave it for the engineer at the next service. A water test shows whether the level is right. If you often have to top up your boiler pressure, fresh water is getting in and diluting the inhibitor. Our guide to a boiler that keeps losing pressure explains the likely causes.
Common problems after cleaning a filter
- Dripping from the cap. The O-ring is dirty, twisted or damaged, or the cap is not seated. Isolate, release the pressure, clean and reseat the O-ring.
- Boiler pressure too low. You lost some water. Repressurise using the filling loop.
- Gurgling or air noises. Air is trapped. Bleed the filter again and then the radiators. Our guide on how to bleed a radiator shows how.
- Valves will not open fully. Some valves stiffen with time. Do not force them; an engineer can free or replace them.
When a filter is not enough
A filter catches sludge that is moving. It does not clear sludge that has already settled in the bottom of radiators. If you have radiators cold at the bottom, black water when you bleed, a noisy boiler or a filter that is full every time you open it, the system needs a proper clean. Our power flushing service drives water and cleaner through each radiator in turn to shift settled sludge, and our article on the signs your radiators need power flushing explains when it makes sense.
What it costs with Vantage
The magnetic filter should be checked and cleaned during a thorough annual boiler service. If you need a filter fitted or a problem looked at, in normal working hours there is no call-out fee. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive.
Frequently asked questions
Do I need to turn the boiler off to clean a magnetic filter?
It is safest to. Some filters have a bypass mode designed for cleaning with the system running, but turning the heating off and letting it cool avoids hot water and moving parts. Always follow your filter’s own instructions.
Will cleaning the magnetic filter lower my boiler pressure?
Usually a little, because some water comes out when you release the pressure and open the cap. Check the gauge afterwards and top up with the filling loop if it is below the level in your boiler’s user guide.
Does a magnetic filter affect my boiler guarantee?
Many boiler manufacturers expect a system filter to be fitted, and some make it a condition of their longer guarantees. Check your boiler’s guarantee terms, and keep the filter cleaned and the inhibitor topped up at every service.
Can I clean a magnetic filter myself?
Yes, if you are comfortable closing valves, releasing pressure and repressurising the boiler. The filter is on the water pipework, outside the boiler. If anything is seized or leaking, stop and call an engineer.
Why is my magnetic filter full of black sludge?
Black sludge is magnetite from corrosion inside the radiators and pipes. A little is normal. A lot, every time, points to low inhibitor, air getting into the system or a system that needs a clean.
Help in Hertfordshire, Bedfordshire and Cambridgeshire
If your filter keeps filling up, is leaking or will not isolate, we can service it, fit a new one or clean the whole system. See our power flushing service or call 01462 506374. The phone is answered 24 hours a day, 7 days a week.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374