How to Drain a Central Heating System Safely, Step by Step
Hertfordshire, Bedfordshire & Cambridgeshire
To drain a central heating system, switch the boiler off and let it cool, stop the water supply to the system, attach a hose to the drain-off valve at the lowest point and run it outside, then open the drain-off and the radiator bleed valves, starting upstairs, to let air in. The exact steps depend on whether you have a sealed system (a combi or system boiler with a pressure gauge) or an open vented system with a tank in the loft, and refilling properly, with inhibitor and the right pressure, matters as much as draining.
- Check first whether you need to drain at all. Removing one radiator usually just means closing its two valves.
- Work out if your system is sealed (pressure gauge, no loft tank) or open vented (small feed and expansion tank in the loft).
- Always switch the boiler off and let the water cool before you start.
- Drain from the lowest drain-off valve to an outside foul drain, and open bleed valves from the top floor down.
- When refilling, add central heating inhibitor, bleed every radiator and bring a sealed system back to its correct cold pressure.
Do you need to drain the whole system?
Draining the whole system is a bigger job than many people expect, and refilling introduces fresh water and air. Before you start, check whether a partial drain would do, or whether the job behind it is one for our central heating repairs team anyway.
| Job | Full drain needed? |
|---|---|
| Removing one radiator to decorate | Usually no. Close both radiator valves, count the turns on the lockshield so you can reset it, and drain just that radiator |
| Replacing a radiator valve | Often yes, unless the pipework can be frozen or isolated |
| Fixing a leak on a pipe | Often yes, or at least the part of the system above the leak |
| Adding or moving radiators | Usually yes |
| Replacing the boiler | Yes |
| Cleaning out sludge | A drain and refill helps a little. A power flush does far more |
| House left empty in winter | Sometimes, to prevent frozen pipes, if frost protection cannot be kept on |
If your radiators are cold at the bottom and warm at the top, draining alone will not shift the sludge. Our guide to a radiator not heating up explains the difference between air and sludge problems, and power flushing is the usual cure for heavy sludge.
Sealed or open vented?
| Sign | Sealed system | Open vented system |
|---|---|---|
| Boiler type | Combi or system boiler | Regular (heat only) boiler |
| Pressure gauge on or near the boiler | Yes | Usually no |
| Filling loop (a braided hose or key-operated valve under the boiler) | Yes | No |
| Small feed and expansion tank in the loft | No | Yes, separate from the larger cold water tank |
The difference matters, because they are filled differently and inhibitor goes in differently.
What you need
- A garden hose long enough to reach outside
- A jubilee clip to hold the hose on the drain-off valve
- An adjustable spanner, or a drain valve key, depending on your drain-off
- A radiator bleed key
- Old towels, a shallow tray and a bucket
- Central heating inhibitor for the refill, sized for your system
- For an open vented system, something to tie up the ball valve arm if the tank has no isolating valve
How to drain the system
Step 1: Switch off and cool down
Turn the boiler off at the controls and at the fused spur, and switch off any immersion heater if the cylinder shares the circuit. Leave the system to cool for at least an hour. Hot system water can scald.
Step 2: Stop the water coming back in
- Sealed system: make sure both valves on the filling loop are closed.
- Open vented system: close the isolating valve on the pipe feeding the small feed and expansion tank in the loft. If there is no valve, tie the float arm of the ball valve up with a strip of wood across the tank so it cannot open.
Step 3: Find the drain-off valve
Look for a small valve with a threaded nozzle at the lowest point of the system. It is often on the pipe beside a downstairs radiator, near the boiler, or at the bottom of the pipework in an airing cupboard. Some radiators have one on the valve body.
Step 4: Attach the hose
Push the hose onto the drain-off nozzle and secure it with a jubilee clip. Run the other end outside to a gully that takes kitchen or bathroom waste, lower than the drain-off. Heating water contains inhibitor and sludge, so it should not go on the garden or into a rainwater drain that runs to a watercourse.
Step 5: Open the drain-off
Open the drain-off valve with the spanner or drain key. Water should start to flow. Keep a towel under the valve in case it weeps.
Step 6: Let the air in
Water drains much faster once air can get in. Open the bleed valves on the radiators, starting on the top floor and working down. On a sealed system, the pressure gauge will fall to zero.
Step 7: Wait
How long it takes depends on the size of the system and the drain-off. When the flow stops, check the lowest radiators. Some pipework runs below the drain-off, and a little water may remain in low runs.
Stay safe
- Never open anything on the boiler itself or remove its casing. Only a Gas Safe registered engineer may work inside a gas boiler.
- Never drain a hot system.
- Old drain-off valves can refuse to close fully afterwards. Have a cap or a replacement ready, or ask an engineer to do it.
- If the heating also heats your hot water, you will have no hot water from the boiler until it is refilled.
- If you are not confident about any step, stop. A flooded ceiling costs far more than a visit.
How to refill the system
Refilling is where most DIY drains go wrong, so take it slowly.
Close everything
Close the drain-off valve fully and remove the hose. Close all the radiator bleed valves.
Refill an open vented system
- Add inhibitor to the feed and expansion tank before you refill, following the dose on the bottle, so it is drawn into the system.
- Open the isolating valve or untie the ball valve so the tank refills and water flows into the system.
- Bleed the radiators, starting downstairs and working up, closing each bleed valve as soon as water appears.
- Check the tank level settles at the float and the ball valve shuts off.
Refill a sealed system
- Open the filling loop valves slowly and let the system fill.
- Bleed each radiator, starting downstairs and working up. The pressure will drop each time, so top up as you go.
- Bring the pressure back to the cold figure in your boiler’s user guide, often around 1 to 1.5 bar, then close both filling loop valves fully.
- If your filling loop is a removable braided hose, disconnect it after use. The water regulations expect a temporary filling connection to be removed once the system is filled.
- Add inhibitor. On a sealed system this usually goes in through a radiator bleed point, a filter or a dosing point using an injector. If you do not have the kit, an engineer can add it.
Run and re-bleed
Switch the boiler back on and run the heating for 20 to 30 minutes. Air collects as the water warms, so bleed the radiators again with the heating off and cool. On a sealed system, recheck the pressure and top up if needed. Our guide to how to bleed a radiator has the detail.
Common mistakes
- Forgetting to isolate the supply. On an open vented system, water keeps flowing from the loft tank and you drain it forever.
- Not letting air in. Without open bleed valves the drain slows to a trickle.
- Skipping inhibitor. Fresh water brings oxygen, and without inhibitor the radiators start to corrode from the inside.
- Leaving a sealed system at the wrong pressure. Too low and the boiler locks out, too high and the relief valve may discharge.
- Leaving the filling loop open. The pressure then creeps up. If yours keeps changing, see our guide to a boiler that keeps losing pressure.
- Draining to the garden. System water with inhibitor and sludge should go to a foul drain.
When to leave it to a professional
Draining and refilling is within reach of a practical homeowner, but it is sensible to call an engineer if:
- the drain-off valve is seized or there is none
- the system has not been drained for many years and the valves are old
- you need to add or move radiators, or replace valves on pipework
- the water that comes out is black and thick with sludge
- the boiler shows a fault after refilling
Our central heating repairs team drains, refills and treats systems as part of radiator, valve and pipework repairs.
What we charge to fix it
Our prices, before you ring
| Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee | £150 + VAT £180 inc VAT |
| Evenings and weekends, first hour including the call-out | £297.60 inc VAT |
| Overnight, first hour including the call-out | £330 inc VAT |
| If a new boiler is the better answer, fitted | from £2,780 inc VAT |
The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.
Frequently asked questions
Should the boiler be off when draining the system?
Yes. Switch it off at the controls and the fused spur before you start, and let the water cool. A boiler that fires with little or no water in the system can be damaged, and hot system water can scald.
Can I drain the central heating and still have hot water?
With a combi boiler, no, because the boiler must be off while the system is empty. With a hot water cylinder that has an immersion heater, you can usually still heat water with the immersion while the heating is drained.
How do I drain a single radiator without draining the system?
Close both radiator valves, counting the turns on the lockshield valve so you can reset it later. Put towels and a tray under the valve, loosen the union nut between the valve and the radiator and let the water drain out, opening the bleed valve to speed it up.
Do I need to add inhibitor after draining?
Yes. Inhibitor protects the inside of the radiators, pipes and boiler from corrosion and scale. Any time you drain and refill, the fresh water dilutes or removes the old inhibitor, so add a new dose for the size of your system.
How often should a heating system be drained?
There is no need to drain a healthy system routinely. Draining is done when work needs it, or as part of cleaning a dirty system. Draining and refilling too often brings in fresh oxygenated water, which can cause more corrosion.
Central heating help in Hertfordshire, Bedfordshire and Cambridgeshire
If you would rather not drain the system yourself, or you have found a problem while doing it, our engineers can help. See our central heating repairs service or call 01462 506374, answered 24 hours a day, 7 days a week.
Need help today?
Call and speak to a person, any hour, any day of the year, or get a fixed price quote online.
Get a fixed price quote Call 01462 506 374Rather have an engineer look at it?
Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374