A stuck diverter valve usually shows as hot water but no heating, heating but no hot water, or radiators getting warm when you run a hot tap. On a combi boiler the diverter valve is inside the sealed boiler casing, so freeing or replacing it is a job for a Gas Safe registered engineer; what you can safely do is rule out the simpler causes first, and on a system with a hot water cylinder, check the motorised valve’s manual lever.

In short

  • A diverter valve in a combi boiler switches the boiler’s heat between the radiators and your hot taps.
  • When it sticks, you lose heating or hot water, or get both at half strength.
  • It is inside the boiler casing, which only a Gas Safe registered engineer may open.
  • Check the pressure, the thermostat, the timer and the tap flow first, then power the boiler off and on once.
  • Engineers free, repair or replace the valve or its motor, and look at why it stuck, which is often sludge or scale.
Ideal boiler installed by Vantage in a fitted cupboard, with copper pipework and a magnetic system filter
One of our boiler installations: an Ideal combi in a fitted cupboard with a magnetic system filter.

What a diverter valve does

A combi boiler heats your radiators and your hot water, but not both at full power at the same time. The diverter valve decides where the heat goes. When you turn on a hot tap, a flow sensor tells the boiler, and the diverter valve switches the hot water from the boiler away from the radiators and through the plate heat exchanger that heats your tap water. When the tap closes, it switches back to the heating.

Most diverter valves have two parts: the valve body, with a spindle or cartridge that moves inside it, and an actuator (a small electric motor or head) that pushes the spindle across. Either part can fail. The spindle can stick with sludge or limescale, the seals can wear, or the motor can burn out. It is a common fault on combi boilers, and a routine boiler repair for a Gas Safe registered engineer.

Homes with a system or regular boiler and a hot water cylinder do not have a diverter valve in the boiler. Instead they have one or more motorised valves on the pipework, usually in the airing cupboard. A three-port mid-position valve does a similar job to a diverter, and these can stick too.

Signs of a stuck diverter valve

What you noticeWhere the valve is probably stuckOther possible causes
Hot water works, but radiators stay coldStuck on the hot water sideThermostat, timer or pump fault; low pressure
Heating works, but taps run cold or lukewarmStuck on the heating sideFlow sensor, plate heat exchanger scale, low tap flow
Radiators get warm when you run a hot tap, with the heating offNot closing fully on the heating sideA passing valve or seal
Hot water is only lukewarm and radiators are warmStuck in the middlePlate heat exchanger or flow sensor
Clicking or buzzing from the boiler when it switchesA failing actuator motorRelays on the circuit board

No hot water with working heating has a few causes besides the diverter valve. Our guide to no hot water but the heating works goes through them. If the problem is the other way round and a radiator is cold on its own, see radiator not heating up.

Check these first

These checks are safe for any homeowner and often find a simpler cause.

  1. Check the boiler pressure. Look at the gauge on the front of the boiler. If it is below the level in the user guide, top it up with the filling loop as the guide explains. Low pressure can stop the boiler running either service.
  2. Check the thermostat and timer. Turn the room thermostat up a few degrees above room temperature, and make sure the programmer is calling for heating. It sounds obvious, but it is a common cause of cold radiators.
  3. Check the hot water flow. Run a hot tap fully open. A combi needs a minimum flow through its flow sensor to switch to hot water. If the flow is weak at every tap, the problem may be the water supply rather than the boiler.
  4. Do the radiator test. With the heating switched off at the thermostat, run a hot tap for a few minutes. If radiators start to warm up, the diverter valve is probably letting water through to the heating when it should not.
  5. Restart the boiler once. Turn it off at the switch or fused spur, wait a minute and turn it back on. Sometimes an actuator that has hung will reset. If the fault comes back, leave it for an engineer.
  6. On a cylinder system, check the motorised valve lever. Find the valve near the cylinder, with a small box on top. Switch the heating and hot water off at the programmer, then move the manual lever on the side of the head. It should move smoothly without force. If it is stiff or will not move, the valve spindle may be seized. Do not take the cover off the head, which has mains wiring inside.

What not to do

  • Do not remove the boiler casing to reach the diverter valve. Only a Gas Safe registered engineer may work inside a gas boiler, and that includes taking off the case.
  • Do not tap the boiler or the pipes with a hammer to try to free the valve. You can crack joints and damage parts.
  • Do not spray lubricant into or around the boiler.
  • Do not keep resetting the boiler if it locks out. A few attempts, then call an engineer.
  • If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows, do not use electrical switches, and turn off the gas at the meter if it is safe to do so.

Why diverter valves stick

  • Sludge. Magnetite from corroding radiators travels round the system and packs into the moving parts of the valve.
  • Limescale. Most of Hertfordshire has hard water. Scale builds up in the hot water side of a combi, including around the valve and the plate heat exchanger.
  • Worn seals. The rubber seals on the spindle wear and let water pass, or drag and stop the spindle moving freely.
  • A failed actuator. The small motor or head that moves the valve burns out or its linkage breaks.
  • Long periods without use. A valve that sits in one position all summer can stick when the heating goes back on in autumn.

How an engineer frees or fixes a diverter valve

A Gas Safe registered engineer will:

  1. Confirm it is the diverter valve by checking what the boiler is being asked to do, watching the valve switch, and testing the actuator’s electrical supply and motor.
  2. Decide which part has failed. On many combis the motor head and the valve body are separate parts, so it is sometimes only the motor that needs replacing.
  3. Isolate and drain the boiler before opening the water side.
  4. Free and clean the valve if the spindle is sticking but undamaged, and replace worn seals where the manufacturer supplies them.
  5. Replace the cartridge, the motor or the whole valve if the parts are worn. Some manufacturers only supply the valve as a complete assembly.
  6. Refill, repressurise, bleed and test both heating and hot water, and check the boiler’s combustion if the case has been opened.
  7. Look at the cause. If the valve stuck because of sludge or scale, it will stick again. That may mean checking the inhibitor, cleaning or fitting a magnetic filter, or a power flush.

Our boiler repair engineers carry common parts on fully stocked vans, although diverter valves vary a lot between makes and models.

Repair or replace the boiler?

A diverter valve is a common, repairable part, and replacing it does not usually mean replacing the boiler. It is worth thinking about a new boiler if:

  • the boiler is old and has had several other major parts replaced;
  • the heat exchanger is also badly scaled or corroded;
  • parts for your model are hard to get.

Our repair or replace guide sets out how we decide. If you want to compare, our boiler quote tool gives you a fixed price for a new boiler online.

What it costs with Vantage

In normal working hours there is no call-out fee. Gas faults start with a fixed-price Gas Safe diagnostic visit, and if we can fix it on the same visit, part of that diagnostic charge comes off the repair. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive. A motor head is usually a smaller part than a complete valve assembly. Our work carries a 12 month labour guarantee.

Frequently asked questions

Can I free a stuck diverter valve myself?

Not on a combi boiler, because the valve is inside the sealed casing and only a Gas Safe registered engineer may work there. You can do the safe checks above, restart the boiler once, and on a cylinder system check the motorised valve lever. Anything more needs an engineer.

How do I know if it is the diverter valve or the boiler?

If the boiler lights and heats one service (heating or hot water) but not the other, the diverter valve is a likely suspect. If it does not light at all, or shows a lockout code, the fault is elsewhere. An engineer can test the valve and its motor to be sure.

Can WD-40 free a stuck diverter valve?

No. The valve is inside the boiler, and spraying lubricant into a gas appliance is unsafe. Even on the spindle of an external motorised valve, a seized spindle usually needs the valve or head replacing rather than oil.

Can a stuck diverter valve cause the boiler to lose pressure?

A diverter valve does not usually leak outside the boiler, but worn seals inside it can let water pass from one side to the other. If your pressure keeps dropping, there is usually another cause, such as a leak or the expansion vessel, and an engineer should check.

Is it safe to keep using the boiler with a stuck diverter valve?

It will not usually cause a dangerous situation, but it can make the boiler work harder or cycle more, and you may be without heating or hot water. Get it looked at rather than living with it.

When to call an engineer

If you have done the checks above and still have heating without hot water, or hot water without heating, book a boiler repair with a Gas Safe registered engineer. We cover Hertfordshire, Bedfordshire and Cambridgeshire. Call 01462 506374, answered 24 hours a day, 7 days a week, with 24/7 emergency cover.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.