To replace a radiator, turn the heating off, close both radiator valves, drain the old radiator into a tray and lift it off its brackets, then fit the new radiator’s tails, bleed valve and blanking plug, hang it, connect it to the valves, open them, bleed out the air and top up the boiler pressure. A like-for-like swap with the same pipe positions is a manageable job for a confident DIYer; if the new radiator is a different width or you need new valves or pipework, it is usually a job for an engineer.

In short

  • Pick a radiator with the right heat output for the room, and measure the distance between the pipes.
  • If the pipe centres match, you can usually swap it without altering any pipework.
  • Close both valves, count the turns on the lockshield, drain the radiator and lift it off.
  • Fit new tails with PTFE tape or jointing compound, hang the radiator level and reconnect.
  • Open the valves, bleed, repressurise the boiler and check every joint for leaks.
Thermal image of a radiator heating evenly after a Vantage power flush
A thermal camera shot of a radiator heating evenly across its whole surface after a power flush.

Power flush price

Cold radiators or sludge? See your fixed price now

Tell us how many radiators you have and what your system is, and you get a fixed power flush price straight away, online.

Instant power flush priceOr call 01462 506 374

Before you start: choose the right radiator

Heat output

A radiator’s job is to put enough heat into the room. Its output is listed in watts (and often BTU) on the manufacturer’s data. Outputs are normally quoted at a standard temperature difference known as Delta T 50, which assumes a fairly hot system. If your boiler runs at lower temperatures, as a modern condensing boiler set up efficiently does, or you have a heat pump, the real output is lower than the headline figure.

If the old radiator heated the room well, choose one with at least the same output. If the room was always cold, a larger or double-panel radiator may be the answer. If you are unsure, our central heating repairs team can work out the heat the room actually needs.

Size and pipe centres

Measure:

  • The pipe centres. The distance between the centre of the two pipes coming up from the floor (or out of the wall). If the new radiator plus its valves fits the same centres, the swap is simple.
  • The height and width of the space, including under windowsills.
  • Which side the pipes are on, and whether they come from the floor or the wall.

Many radiators are made in standard sizes to make like-for-like swaps easier, and some manufacturers make replacement radiators designed to match older sizes. Extendable valve tails can take up a small difference.

Tools and materials

  • Two adjustable spanners or grips (one to hold, one to turn)
  • A radiator key and a flat-headed screwdriver
  • A shallow tray, a bucket and plenty of old towels
  • PTFE tape or a jointing compound suitable for heating systems
  • A spirit level, tape measure, drill and fixings suitable for your wall
  • A hex key or valve tail tool for the radiator tails
  • Inhibitor, to replace what is lost, and the boiler’s user guide for repressurising

Step 1: turn off and isolate

  1. Turn the heating off and let the system cool completely.
  2. Close the thermostatic or wheel valve on one end of the radiator.
  3. Close the lockshield valve on the other end. Pull off its cap and turn the spindle clockwise with a spanner. Count the turns and write them down, so you can reopen it to the same point and keep the system balanced.

Step 2: drain and remove the old radiator

  1. Protect the floor with towels and put the tray under one valve. Radiator water is often black and it stains.
  2. Undo the union nut between the valve and the radiator, holding the valve body steady with a second spanner so you do not strain the pipe.
  3. Open the bleed valve at the top of the radiator. Air getting in lets the water drain out faster.
  4. Let it drain fully, emptying the tray as you go. When it stops, undo the union nut on the other side.
  5. Lift the radiator off its brackets. Keep the open ends up or plug them with a rag so the remaining sludge does not spill. Radiators are heavier than they look, so get help with a large one.

Step 3: prepare the new radiator

  1. Fit the tails. Wrap the threads of the new valve tails with PTFE tape or jointing compound and screw them firmly into the bottom corners of the radiator.
  2. Fit the bleed valve and blanking plug in the top corners, sealed the same way.
  3. Offer it up to the valves. Check that the tails line up with the valves before you drill anything.

Step 4: fit the brackets and hang it

If the new radiator uses the same bracket positions, you may be able to reuse the old brackets, but new radiators usually come with their own.

  1. Mark the bracket positions so the radiator’s tails meet the valves at the right height.
  2. Check it is level. Many installers set the radiator very slightly higher at the bleed valve end so air collects there.
  3. Drill and fix the brackets with fixings that suit the wall. Plasterboard and stud walls need the right fixings, or brackets fixed into the studs, to take the weight of a full radiator.
  4. Hang the radiator and check it sits firmly.

Step 5: connect, fill and test

  1. Tighten the union nuts onto the tails, holding the valves steady with a second spanner. Firm, but do not overtighten.
  2. Open the thermostatic or wheel valve, then the lockshield, back to the number of turns you counted.
  3. Bleed the radiator until water, not air, comes out. Our guide on how to bleed a radiator walks through it.
  4. Repressurise the boiler if you have a combi or system boiler, using the filling loop as described in its user guide. On an older system with a tank in the loft, it refills itself.
  5. Turn the heating on and check every joint with dry tissue as the system warms up.
  6. Bleed again once it is hot, and top up the pressure if needed.
  7. Add inhibitor. Draining a radiator removes some of the inhibitor that protects the system from corrosion. An engineer can top it up, and on a sealed system it is usually added through a radiator or a filter.

Know when to stop

  • If the valves will not close fully, do not undo the radiator. Water will keep coming. The system needs draining or the pipe freezing, which is an engineer’s job.
  • Do not force seized union nuts or valves on old pipework. Old pipes can crack or twist.
  • If water comes near sockets or electrics, switch off at the consumer unit before touching anything.
  • Never remove the boiler casing. Only a Gas Safe registered engineer may work inside a gas boiler.

When the new radiator does not match

If the pipe centres do not line up, the choices are:

SituationOptionWho does it
A few millimetres outExtendable valve tailsOften DIY
A few centimetres outAlter the pipes below the floor or from the wallAn engineer, with the system drained
Pipes on the wrong side, or from the wall instead of the floorRe-route the pipeworkAn engineer
Moving the radiator to another wallNew pipework runsAn engineer
New valves or thermostatic valves at the same timeDrain the system or freeze the pipesAn engineer

If you are replacing several radiators, it is often worth doing them together with the system drained and fitting new thermostatic valves at the same time.

Why the old radiator failed

If you are replacing a radiator because it is cold at the bottom or leaking from the panel, the problem is probably inside the system. Sludge and corrosion build up over years. Putting a new radiator on dirty system water means it starts corroding too. Signs the whole system needs attention include:

  • other radiators cold at the bottom;
  • black water when you bleed;
  • a noisy boiler or pump.

Our guide to a radiator not heating up helps you narrow it down, and a power flush cleans the system so the new radiators stay clean. If you are replacing most of the radiators or changing the layout, our central heating installation team can design the system as a whole.

How we price it

Swapping a radiator is charged at our published rates. In normal working hours there is no call-out fee. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive. Larger jobs, such as several radiators or new pipework, are quoted as a fixed price after a free survey. Our work carries a 12 month labour guarantee.

Frequently asked questions

Do I need to drain the whole system to replace a radiator?

Not usually. If both radiator valves close fully, you can drain just that radiator. If the valves pass water or you are changing them too, the system needs draining down or the pipes need freezing.

Can I replace a radiator with a bigger one?

Yes, as long as the pipes can be moved or the new radiator fits the existing centres, and your boiler has enough spare output. Adding lots of extra radiator capacity to an older boiler is worth checking with an engineer.

How long does it take to replace a radiator?

A like-for-like swap is often done in a morning. If the pipework needs altering or the system needs draining, it takes longer.

Should I change the radiator valves at the same time?

It is a good idea if the valves are old, stiff or leaking, or if you want thermostatic valves for better control. Changing valves means draining the system or freezing the pipes, so it is usually an engineer’s job.

Do I need to add inhibitor after replacing a radiator?

Yes, ideally. Draining and refilling brings fresh water into the system and dilutes the inhibitor that protects it from corrosion. Adding the right dose afterwards keeps the new radiator and the boiler protected.

Help in Hertfordshire, Bedfordshire and Cambridgeshire

If your pipes do not line up, your valves will not close, or you would simply rather it was done for you, our central heating repairs team can swap radiators, change valves and clean the system. Call 01462 506374, answered 24 hours a day, 7 days a week.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.