How to Repressurise a Boiler: Step-by-Step Guide
Hertfordshire, Bedfordshire & Cambridgeshire
To repressurise a boiler, turn the boiler off and let it cool, find the filling loop (usually under the boiler), open its valves slowly while watching the pressure gauge, and close them when the needle reaches 1 to 1.5 bar. Then switch the boiler back on and reset it if it shows a fault. Topping up once or twice a year is normal, but if you are doing it every few weeks the system has a leak or a faulty part that needs an engineer.
In short
- Most boilers want 1 to 1.5 bar when cold. It will rise a little when the heating is running.
- Only sealed systems (combi and system boilers) have a pressure gauge and filling loop.
- Filling loops come in three main types: an external hose, a keyed filling link and a keyless lever.
- If you overfill, bleed a radiator to bring the pressure back down.
- Losing pressure again soon after topping up means a leak, a faulty pressure relief valve or a flat expansion vessel.

Check the pressure gauge first
The pressure gauge is on the front of most modern boilers, either as a dial or as a number on the digital display. On older boilers it can be underneath. Check it with the heating off and the boiler cold.
| Reading (boiler cold) | What it means | What to do |
|---|---|---|
| Below 0.5 bar | Very low. Most boilers lock out and show a fault | Top up to 1 to 1.5 bar |
| 0.5 to 1 bar | Low. The boiler may work but can cut out | Top up to 1 to 1.5 bar |
| 1 to 1.5 bar | Normal for most boilers | Nothing |
| 1.5 to 2 bar when hot | Normal while the heating is running | Nothing |
| Above 2.5 bar | Too high | Bleed a radiator to reduce it, then find out why |
Always check your own user guide, as the exact figure can vary by model. Ideal and Worcester Bosch both give 1 to 1.5 bar as the normal cold pressure.
Many boilers show a low pressure fault code when the pressure drops too far, for example Ideal F1 and Vaillant F22. Once the pressure is back up, the fault usually clears with a reset. If it does not, or the pressure will not hold, our boiler repair engineers can find out why.
Does your boiler have a filling loop?
Only sealed heating systems need topping up by hand. That means combi boilers and system boilers (with a hot water cylinder but no tanks in the loft).
If you have a regular (heat-only) boiler with a small feed and expansion tank in the loft, the system tops itself up from that tank. There is no filling loop and usually no pressure gauge. If radiators on that type of system are low on water, the tank or its ball valve needs checking.
Find your filling loop
| Type | What it looks like | How it works |
|---|---|---|
| External filling loop | A braided silver hose between two pipes under the boiler, each end with a small valve | Open both valves slowly to let mains water into the heating |
| Integrated filling link (horseshoe) | A fixed rigid or flexible link under the boiler, sometimes behind a panel | Open the valve or valves on the link slowly |
| Keyed filling link | A white plastic key that fits into a socket under the boiler, common on Worcester Bosch combis | Insert the key, lock it, then turn the knob to fill |
| Keyless filling link | A blue lever under the boiler, on some Worcester Bosch combis | Pull the lever down to fill, release to stop |
On a system boiler the filling loop may be near the hot water cylinder or in an airing cupboard rather than under the boiler. Ideal advises not to operate any valve under the boiler that you cannot clearly identify. If you are not sure which valve is which, stop and call an engineer.
How to repressurise a boiler, step by step
- Turn the heating off and let the boiler cool. Pressure rises as the water warms, so filling a hot system gives a false reading.
- Find the pressure gauge and note the reading.
- Find the filling loop and identify its valves or controls. On an external loop, check both ends of the hose are connected firmly.
- Open the filling valve slowly. On a loop with two valves, open one fully, then open the second a little at a time. You will hear water flowing.
- Watch the gauge as the needle rises.
- Close the valve or valves when it reaches 1 to 1.5 bar, or the figure in your user guide. Make sure they are fully closed, or the pressure will keep creeping up.
- Switch the boiler back on. If it shows a fault code, press the reset button once, as described in your user guide.
- Check again after the heating has run. If you bled any radiators, the pressure will have dropped and may need a small top-up.
On an external loop, many manufacturers recommend disconnecting the hose afterwards and refitting the caps. Put a towel down first, as a little water will come out.
Keyed filling link (Worcester Bosch)
Worcester Bosch’s filling guide describes lining up the arrow on the white key with the open padlock symbol, inserting it and turning it to lock, then turning the white knob to let water in. When the gauge reaches the right zone, turn the knob back and remove the key in reverse order. Do not overtighten the knob.
Keyless filling link (Worcester Bosch)
Pull the blue lever under the boiler down and hold it while you watch the gauge. Release it when the pressure reaches the right zone.
If you overfill it
It is easy to overshoot. If the pressure is above 1.5 bar with the boiler cold, bleed a radiator:
- Make sure the heating is off and the radiators are cool.
- Hold a cloth under the bleed valve and open it slowly with a radiator key.
- Let water out until the gauge drops to the right level, then close the valve.
If pressure keeps rising on its own with the filling valves closed, a valve is letting by, and it needs an engineer. Very high pressure can make the pressure relief valve open and discharge water through a pipe outside, often by the boiler.
Safety: what not to do
- Never remove the boiler casing or touch anything inside it. Under the Gas Safety (Installation and Use) Regulations, only a Gas Safe registered engineer may work on a gas appliance.
- Do not open valves you cannot identify, and do not touch the gas valve under the boiler.
- Do not keep topping up a boiler that loses pressure quickly. Water leaking inside the case can damage electrical parts.
- If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows, do not use electrical switches, and turn off the gas at the meter if it is safe to do so.
Why boilers lose pressure
A small drop over months is normal, and bleeding radiators always lowers it. Ideal says topping up once or twice a year is generally not a concern. If you are doing it much more often, one of these is usually to blame:
| Cause | What you might notice | Can you fix it yourself? | What the engineer does |
|---|---|---|---|
| Leak on a radiator valve or pipe | Damp patches, rust marks, drips | Sometimes, by tightening a gland nut gently | Finds and repairs the leak |
| Hidden leak under floors | Pressure drops with no visible water | No | Traces the leak |
| Pressure relief valve letting by | Pipe outside dripping, often after heating | No | Tests and replaces the valve |
| Expansion vessel lost its charge | Pressure swings high when hot, low when cold | No | Recharges or replaces the vessel |
| Leak inside the boiler | Water under the boiler | No | Opens the case and repairs it |
Our guide to a boiler that keeps losing pressure goes through each cause in detail. If you need it sorted, our boiler repair team covers all the major brands, and the phone is answered 24 hours a day, 7 days a week.
What we charge to fix it
Our prices, before you ring
| Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee | £150 + VAT £180 inc VAT |
| Evenings and weekends, first hour including the call-out | £297.60 inc VAT |
| Overnight, first hour including the call-out | £330 inc VAT |
| If a new boiler is the better answer, fitted | from £2,780 inc VAT |
The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.
Frequently asked questions
What should my boiler pressure be?
For most combi and system boilers, 1 to 1.5 bar when the system is cold. It is normal for it to rise towards 2 bar when the heating is running. Your user guide gives the exact figure for your model.
Can I repressurise my boiler with the heating on?
It is better to turn the heating off and let the system cool first. Filling while hot gives a higher reading, so when the system cools the pressure can end up too low.
How often should I have to repressurise my boiler?
Once or twice a year is normal, especially after bleeding radiators. If you need to top up every few weeks or more, there is a leak or a faulty component that needs an engineer.
Why has my boiler pressure gone up after repressurising?
Either the filling valve is not fully closed and water is still getting in, or you filled it while cold and it has risen with the heat. If it goes above 2.5 bar, bleed a radiator. If it keeps rising with the valves shut, call an engineer.
I cannot find the filling loop. What should I do?
Look under the boiler, then near the hot water cylinder or in the airing cupboard for a system boiler. Some combis have the loop behind a small panel at the bottom. If you still cannot find it, or the loop has been removed, an engineer can top up the system and fit one.
Help with boiler pressure in Hertfordshire, Bedfordshire and Cambridgeshire
If your boiler keeps losing pressure or will not hold it after topping up, our Gas Safe engineers can find the cause. See our boiler repair page or call 01462 506374.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374