Skip to main content

Vantage Plumbing and Heating

How to Reset a Boiler and What Boiler Lockout Means

Hertfordshire, Bedfordshire & Cambridgeshire

Fully Stocked Vans12 Month Labour GuaranteeGas Safe Registered 956889

To reset a boiler, note the fault code on the display, fix any simple cause you can (such as low pressure or a frozen condensate pipe), then press the reset button once, holding it for a few seconds if your user guide says so. A boiler goes into lockout when a safety check fails and it shuts itself down, so resetting is only safe a small number of times: if the same code comes back, the boiler needs a Gas Safe registered engineer, not more resets.

In short

  • Lockout is a safety shutdown. The boiler stops and shows a code or a light until it is reset.
  • Read the code first. It tells you whether the cause is something you can check.
  • Check the pressure, the condensate pipe in cold weather, the gas supply and the power before resetting.
  • Reset once or twice at most. Some boilers lock themselves out further if they are reset too many times.
  • A boiler that keeps locking out has a fault that needs an engineer.
Ideal boiler installed by Vantage in a fitted cupboard, with copper pipework and a magnetic system filter
One of our boiler installations: an Ideal combi in a fitted cupboard with a magnetic system filter.

What boiler lockout means

A modern boiler runs a set of safety checks every time it fires. If it cannot detect a flame, the water pressure is too low, it is overheating, or the condensate cannot drain away, it shuts down and stays off. That is lockout. Vaillant describes it simply: when a boiler detects a fault, it shuts itself down as a safety precaution.

Lockout protects you and the boiler. It stops gas being released without a flame, and stops the boiler running dry or overheating. It is not the same as a boiler that is simply off.

What you seeWhat it usually meansWhat to do
Fault code and a reset symbol or flashing lightLockout after a failed safety checkCheck the cause, then reset once
Fault code but no reset optionA fault that clears on its own once the cause is fixed, or needs an engineerCheck the code in your user guide
No display at allNo power to the boilerCheck the fused spur, plug and consumer unit
Display normal but no heatControls, not the boilerCheck the thermostat, timer and programmer

Codes that mean lockout differ by brand. On Ideal boilers, codes shown as L and a number are lockouts, for example Ideal L2, which Ideal lists as flame loss or ignition lockout. On Vaillant boilers, F28 means the flame was not detected during ignition.

Check these before you reset

Resetting without fixing the cause just leads to another lockout. Work through these first. They are all safe for a homeowner.

  1. Write down the code. Look it up in your user guide or our fault code guides. It tells you where to look.
  2. Check the pressure gauge. Most boilers want 1 to 1.5 bar when cold. If it is low, top it up with the filling loop as your user guide describes, then reset.
  3. Check the gas supply. Is the hob working? On a prepayment meter, check there is credit. If no gas appliances work, the problem is the supply, not the boiler.
  4. In freezing weather, check the condensate pipe. This plastic pipe carries water from the boiler to a drain, often outside. If it freezes, the boiler locks out. Thaw it with warm, not boiling, water. Our guide to a frozen condensate pipe shows how.
  5. Check the power. Make sure the fused spur next to the boiler is on and the fuse has not blown, and that nothing has tripped at the consumer unit.
  6. Check the controls. Make sure the thermostat is set above room temperature and the timer is calling for heat.

If you would rather not work through it yourself, our boiler repair team covers all the major brands, and the phone is answered 24 hours a day, 7 days a week.

How to reset a boiler, step by step

The reset button looks different on every boiler, so keep your user guide to hand.

  1. Find the reset button. It may be marked “reset” or “restart”, or show a flame with a line through it or a circular arrow. On some boilers it is under a flap.
  2. Press it once. Some boilers need the button held for a few seconds. Vaillant’s advice is to press and hold for three seconds.
  3. Wait. The boiler will run through its start-up sequence, which can take a few minutes. Vaillant notes some boilers may need two attempts.
  4. Check it is working. Run a hot tap or turn the thermostat up and confirm the heating comes on.
  5. If it locks out again, stop resetting and call a Gas Safe registered engineer. Note the code so you can pass it on.

On some Ideal models, certain codes clear by switching the power to the boiler off and on again rather than pressing reset. Your user guide says which.

How many times can you reset a boiler?

Once or twice. Each reset starts another ignition attempt, and if the fault is still there it will lock out again. Ideal’s fault code list even includes a separate lockout for a boiler that has been reset too many times in 15 minutes. If that happens, wait before trying again rather than pressing the button repeatedly.

A boiler that locks out every day, or several times a week, is telling you something is wrong. Common causes are below.

Common causes of repeated lockout

CauseWhat you might noticeCan you fix it yourself?What the engineer does
Low water pressureGauge below 1 bar, low pressure codeYes, top up with the filling loopFinds the leak if it keeps dropping
Frozen or blocked condensate pipeLockout in cold weather, gurglingYes, thaw with warm waterReroutes or insulates the pipe
Gas supply problemOther gas appliances also off, or no meter creditCheck the meter and creditChecks the gas pressure at the boiler
Ignition or flame sensing faultClicking but no flame, ignition codeNoChecks the electrode, sensor and gas valve
Fan or flue problemFan noise changes, flue codeNoTests the fan, pressure sensing and flue
OverheatingCode after running for a while, radiators patchyBleed radiators if air is presentChecks the pump, sludge and valves
Faulty PCB or wiringRandom lockouts, display issuesNoTests and replaces faulty parts

If the boiler will not fire at all, our guide to a boiler not firing up goes through the causes.

What not to do

  • Do not keep pressing reset. Repeated resets can make some boilers lock out further, and do not fix the cause.
  • Never remove the boiler casing or touch anything inside it, including the gas valve, fan, PCB, heat exchanger or flue. Under the Gas Safety (Installation and Use) Regulations, only a Gas Safe registered engineer may work on a gas appliance.
  • Do not use boiling water on a frozen condensate pipe. It can crack the plastic.
  • If you smell gas, do not reset the boiler. Call the National Gas Emergency Service on 0800 111 999, open windows, do not use electrical switches, and turn off the gas at the meter if it is safe to do so.

What an engineer will check

A Gas Safe engineer will read the code and the boiler’s fault history, check the gas pressure at the boiler, test the ignition electrode and flame sensor, check the fan and flue, test the pump and heat exchanger for flow, and look at the condensate route. Most lockout faults come down to one part, which can be tested and replaced. If you are in a hurry, our broken boiler emergency checklist covers what to do while you wait.

What we charge to fix it

Our prices, before you ring

Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee£150 + VAT
£180 inc VAT
Evenings and weekends, first hour including the call-out£297.60
inc VAT
Overnight, first hour including the call-out£330
inc VAT
If a new boiler is the better answer, fittedfrom £2,780
inc VAT

The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.

Frequently asked questions

Is it safe to reset my boiler?

Yes, pressing the reset button once or twice is safe and is exactly what the manufacturers intend. It is not safe to keep resetting a boiler that keeps locking out, or to reset it at all if you can smell gas.

Where is the reset button on my boiler?

It is usually on the front control panel, marked “reset” or “restart” or with a flame symbol. On some boilers it is behind a small flap. Your user guide shows exactly where.

Why does my boiler keep going into lockout?

Something is failing one of its safety checks. The common causes are low pressure, a frozen condensate pipe, a gas supply problem, or a faulty ignition part, fan or sensor. The fault code points to which.

Will turning the power off and on reset my boiler?

On some boilers and for some codes, yes, but it is not a substitute for the reset button where one is fitted. Check your user guide. Do not turn the power off repeatedly to force a boiler that keeps locking out.

Do I need to reset my boiler after a power cut?

Usually not. Most boilers restart on their own when the power returns. If the display shows a fault code afterwards, a single reset normally clears it. Check the programmer and timer, as some lose their settings.

Help with boiler lockouts in Hertfordshire, Bedfordshire and Cambridgeshire

If your boiler will not reset or keeps locking out, our Gas Safe engineers can find the fault. See our boiler repair page or call 01462 506374.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.