To reset a boiler, note the fault code on the display, fix any simple cause you can (such as low pressure or a frozen condensate pipe), then press the reset button once, holding it for a few seconds if your user guide says so. A boiler goes into lockout when a safety check fails and it shuts itself down, so resetting is only safe a small number of times: if the same code comes back, the boiler needs a Gas Safe registered engineer, not more resets.
In short
- Lockout is a safety shutdown. The boiler stops and shows a code or a light until it is reset.
- Read the code first. It tells you whether the cause is something you can check.
- Check the pressure, the condensate pipe in cold weather, the gas supply and the power before resetting.
- Reset once or twice at most. Some boilers lock themselves out further if they are reset too many times.
- A boiler that keeps locking out has a fault that needs an engineer.

What boiler lockout means
A modern boiler runs a set of safety checks every time it fires. If it cannot detect a flame, the water pressure is too low, it is overheating, or the condensate cannot drain away, it shuts down and stays off. That is lockout. Vaillant describes it simply: when a boiler detects a fault, it shuts itself down as a safety precaution.
Lockout protects you and the boiler. It stops gas being released without a flame, and stops the boiler running dry or overheating. It is not the same as a boiler that is simply off.
| What you see | What it usually means | What to do |
|---|---|---|
| Fault code and a reset symbol or flashing light | Lockout after a failed safety check | Check the cause, then reset once |
| Fault code but no reset option | A fault that clears on its own once the cause is fixed, or needs an engineer | Check the code in your user guide |
| No display at all | No power to the boiler | Check the fused spur, plug and consumer unit |
| Display normal but no heat | Controls, not the boiler | Check the thermostat, timer and programmer |
Codes that mean lockout differ by brand. On Ideal boilers, codes shown as L and a number are lockouts, for example Ideal L2, which Ideal lists as flame loss or ignition lockout. On Vaillant boilers, F28 means the flame was not detected during ignition.
Check these before you reset
Resetting without fixing the cause just leads to another lockout. Work through these first. They are all safe for a homeowner.
- Write down the code. Look it up in your user guide or our fault code guides. It tells you where to look.
- Check the pressure gauge. Most boilers want 1 to 1.5 bar when cold. If it is low, top it up with the filling loop as your user guide describes, then reset.
- Check the gas supply. Is the hob working? On a prepayment meter, check there is credit. If no gas appliances work, the problem is the supply, not the boiler.
- In freezing weather, check the condensate pipe. This plastic pipe carries water from the boiler to a drain, often outside. If it freezes, the boiler locks out. Thaw it with warm, not boiling, water. Our guide to a frozen condensate pipe shows how.
- Check the power. Make sure the fused spur next to the boiler is on and the fuse has not blown, and that nothing has tripped at the consumer unit.
- Check the controls. Make sure the thermostat is set above room temperature and the timer is calling for heat.
If you would rather not work through it yourself, our boiler repair team covers all the major brands, and the phone is answered 24 hours a day, 7 days a week.
How to reset a boiler, step by step
The reset button looks different on every boiler, so keep your user guide to hand.
- Find the reset button. It may be marked “reset” or “restart”, or show a flame with a line through it or a circular arrow. On some boilers it is under a flap.
- Press it once. Some boilers need the button held for a few seconds. Vaillant’s advice is to press and hold for three seconds.
- Wait. The boiler will run through its start-up sequence, which can take a few minutes. Vaillant notes some boilers may need two attempts.
- Check it is working. Run a hot tap or turn the thermostat up and confirm the heating comes on.
- If it locks out again, stop resetting and call a Gas Safe registered engineer. Note the code so you can pass it on.
On some Ideal models, certain codes clear by switching the power to the boiler off and on again rather than pressing reset. Your user guide says which.
How many times can you reset a boiler?
Once or twice. Each reset starts another ignition attempt, and if the fault is still there it will lock out again. Ideal’s fault code list even includes a separate lockout for a boiler that has been reset too many times in 15 minutes. If that happens, wait before trying again rather than pressing the button repeatedly.
A boiler that locks out every day, or several times a week, is telling you something is wrong. Common causes are below.
Common causes of repeated lockout
| Cause | What you might notice | Can you fix it yourself? | What the engineer does |
|---|---|---|---|
| Low water pressure | Gauge below 1 bar, low pressure code | Yes, top up with the filling loop | Finds the leak if it keeps dropping |
| Frozen or blocked condensate pipe | Lockout in cold weather, gurgling | Yes, thaw with warm water | Reroutes or insulates the pipe |
| Gas supply problem | Other gas appliances also off, or no meter credit | Check the meter and credit | Checks the gas pressure at the boiler |
| Ignition or flame sensing fault | Clicking but no flame, ignition code | No | Checks the electrode, sensor and gas valve |
| Fan or flue problem | Fan noise changes, flue code | No | Tests the fan, pressure sensing and flue |
| Overheating | Code after running for a while, radiators patchy | Bleed radiators if air is present | Checks the pump, sludge and valves |
| Faulty PCB or wiring | Random lockouts, display issues | No | Tests and replaces faulty parts |
If the boiler will not fire at all, our guide to a boiler not firing up goes through the causes.
What not to do
- Do not keep pressing reset. Repeated resets can make some boilers lock out further, and do not fix the cause.
- Never remove the boiler casing or touch anything inside it, including the gas valve, fan, PCB, heat exchanger or flue. Under the Gas Safety (Installation and Use) Regulations, only a Gas Safe registered engineer may work on a gas appliance.
- Do not use boiling water on a frozen condensate pipe. It can crack the plastic.
- If you smell gas, do not reset the boiler. Call the National Gas Emergency Service on 0800 111 999, open windows, do not use electrical switches, and turn off the gas at the meter if it is safe to do so.
What an engineer will check
A Gas Safe engineer will read the code and the boiler’s fault history, check the gas pressure at the boiler, test the ignition electrode and flame sensor, check the fan and flue, test the pump and heat exchanger for flow, and look at the condensate route. Most lockout faults come down to one part, which can be tested and replaced. If you are in a hurry, our broken boiler emergency checklist covers what to do while you wait.
What we charge to fix it
Our prices, before you ring
| Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee | £150 + VAT £180 inc VAT |
| Evenings and weekends, first hour including the call-out | £297.60 inc VAT |
| Overnight, first hour including the call-out | £330 inc VAT |
| If a new boiler is the better answer, fitted | from £2,780 inc VAT |
The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.
Frequently asked questions
Is it safe to reset my boiler?
Yes, pressing the reset button once or twice is safe and is exactly what the manufacturers intend. It is not safe to keep resetting a boiler that keeps locking out, or to reset it at all if you can smell gas.
Where is the reset button on my boiler?
It is usually on the front control panel, marked “reset” or “restart” or with a flame symbol. On some boilers it is behind a small flap. Your user guide shows exactly where.
Why does my boiler keep going into lockout?
Something is failing one of its safety checks. The common causes are low pressure, a frozen condensate pipe, a gas supply problem, or a faulty ignition part, fan or sensor. The fault code points to which.
Will turning the power off and on reset my boiler?
On some boilers and for some codes, yes, but it is not a substitute for the reset button where one is fitted. Check your user guide. Do not turn the power off repeatedly to force a boiler that keeps locking out.
Do I need to reset my boiler after a power cut?
Usually not. Most boilers restart on their own when the power returns. If the display shows a fault code afterwards, a single reset normally clears it. Check the programmer and timer, as some lose their settings.
Help with boiler lockouts in Hertfordshire, Bedfordshire and Cambridgeshire
If your boiler will not reset or keeps locking out, our Gas Safe engineers can find the fault. See our boiler repair page or call 01462 506374.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374