How to Reset a Worcester Bosch Boiler (Greenstar, 4000 and 8000)
Hertfordshire, Bedfordshire & Cambridgeshire
To reset a Worcester Bosch boiler, press and hold the reset button on older Greenstar models such as the i, Si, Ri and CDi until the display shows the boiler is resetting, or on the newer Greenstar 4000 and 8000 press the up and down arrow keys together until Reset appears. Check the pressure gauge, gas supply and condensate pipe first, and only reset two or three times, because a fault that keeps coming back needs a Gas Safe registered engineer.
In short
- A reset clears a lockout and lets the boiler try to start again. It does not repair anything.
- Older Greenstar boilers have a reset button. The 4000 and 8000 are reset from the arrow keys.
- Before you reset, check the pressure is between 1 and 1.5 bar, the gas is on and the condensate pipe is not frozen.
- Some faults clear themselves once the cause is fixed. Others lock the boiler out until you reset it.
- If the boiler locks out again after two or three resets, stop and book a repair.
What a reset does
When a Worcester Bosch boiler detects a problem that could make it unsafe to keep running, such as failing to light or getting too hot, it shuts down and locks out. The display shows a fault code and, on many models, the reset button or the power light flashes. A reset tells the boiler to clear the lockout and run its start-up sequence again.
That is all it does. If the cause was temporary, such as a brief interruption to the gas or a condensate pipe that has now thawed, the boiler will run normally. If the cause is still there, it will lock out again. That is why the checks before you reset matter more than the reset itself, and why a boiler that keeps locking out needs a boiler repair rather than more resets.
How to reset your Worcester Bosch boiler, model by model
Worcester Bosch has built several generations of control panel. Find yours below, and if in doubt check the user instructions for your model on Worcester Bosch’s website.
| Model | Where the reset is | How to reset |
|---|---|---|
| Greenstar 4000 and 8000 range | Arrow keys on the control panel | Press the up and down arrow keys together until Reset shows. The boiler restarts and shows the flow temperature |
| Greenstar i, Si, Ri and i System (with a reset button) | Button marked reset on the control panel | Press and hold the reset button. Reset briefly shows and the boiler restarts after a few seconds |
| Greenstar CDi Classic | Reset button, which flashes with the power light when there is a fault | Press the reset button for three seconds |
| Older Greenstar HE models | Reset button on the control panel | Press and hold until the display shows two dashes, then release |
After a reset, give the boiler a couple of minutes. It will run a fan check and try to light. If it succeeds, the burner comes on and the display goes back to normal.
After thawing a frozen condensate pipe
Worcester Bosch’s user instructions for the Greenstar i and CDi models give a specific routine: once the condensate pipe has been thawed, press the reset button for five seconds and wait two to three minutes for the boiler to restart.
Check these before you press reset
- The pressure gauge. With the boiler cold, Worcester Bosch recommends 1 to 1.5 bar. Below 1 bar the boiler may stop and need topping up and resetting. Top up with the filling loop only if your user instructions show you how. If it keeps dropping, see our guide to a boiler that keeps losing pressure.
- The gas supply. Check that the hob lights and, if you have a prepayment meter, that it has credit.
- The condensate pipe. In freezing weather a blocked condensate pipe is one of the most common causes of a lockout, often with a gurgling noise. Worcester Bosch advises thawing it with a hot water bottle, a microwaveable heat pack or a cloth soaked in hot water, never boiling water, and only where the pipe is at ground level. Our frozen condensate pipe guide goes through it.
- The power. Check the fused spur and any timer or isolator next to the boiler are on.
- The controls. Make sure the thermostat and timer are calling for heat, or the boiler may simply be waiting.
- Note the fault code. Write down the code before you reset, as an engineer will ask for it.
Then reset, once. If it locks out again, try a second time after rechecking the above. After two or three attempts, stop and book an engineer.
What not to do
- Do not keep pressing reset. Each attempt runs an ignition sequence that has already failed, and repeated lockouts can hide a problem that needs attention.
- Do not remove the casing or touch the gas valve, fan, electrodes, control board or anything inside the boiler. Under the Gas Safety (Installation and Use) Regulations 1998 only a Gas Safe registered engineer may work on a gas appliance, and Worcester Bosch itself warns against trying to fix a broken boiler yourself.
- Do not thaw a condensate pipe at height, and never use boiling water on it.
- If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows, do not use electrical switches and turn off the gas at the meter if it is safe.
Why the reset did not work
If the boiler will not stay running after a reset, the fault is still there. These are the usual reasons.
| Cause | What you might notice | Can you fix it yourself? | What the engineer does |
|---|---|---|---|
| Low system pressure | Gauge below 1 bar, pressure code | Yes, by topping up if the user guide allows | Finds the leak or replaces the expansion vessel or pressure relief valve |
| Frozen or blocked condensate | Freezing weather, gurgling, repeated lockout | Yes, by thawing at ground level | Clears the trap and insulates or reroutes the pipe |
| No gas or low gas pressure | Hob will not light, or lockout under load | Only meter credit or the meter valve | Checks the supply and the working pressure |
| Ignition or flame sensing fault | Boiler clicks but will not light, flame code | No | Checks and replaces the electrode or leads |
| Overheating | Lockout after running, noisy boiler | Partly, by bleeding radiators | Checks the pump, flow and sludge |
| Fan or sensor fault | Code on every restart | No | Tests and replaces the part |
| Control board fault | Codes that make no sense or unresponsive display | No | Tests the board before replacing it |
Some fault codes are not lockouts at all. A code caused by low pressure, for example, can clear itself once the pressure is restored. Others, such as a failure to detect a flame, lock the boiler out until it is reset. Our guides to Worcester Bosch EA (no flame detected) and the full Worcester Bosch fault code list explain the common ones.
What an engineer will check
A good engineer starts with the fault history rather than the part they suspect. Where the boiler’s service menu holds a record of recent faults, it shows whether a lockout is a one-off or a pattern. From there we check gas working pressure, the condensate route and trap, the ignition and flame sensing electrodes, water pressure and flow, and the fan, then confirm the boiler is burning correctly with a flue gas analyser. A boiler that needed repeated resets usually has a worn part that an annual boiler service would have caught.
What we charge to fix it
Our prices, before you ring
| Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee | £150 + VAT £180 inc VAT |
| Evenings and weekends, first hour including the call-out | £297.60 inc VAT |
| Overnight, first hour including the call-out | £330 inc VAT |
| If a new boiler is the better answer, fitted | from £2,780 inc VAT |
The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.
Frequently asked questions
How many times can I reset a Worcester Bosch boiler?
Two or three times at most. If it locks out again, the cause has not gone away, and continuing to reset will not fix it. Book an engineer and give them the fault code.
How long does a Worcester Bosch boiler take to reset?
The reset itself takes a few seconds. The boiler then runs its start-up checks and tries to light, which can take a minute or two. After thawing a condensate pipe, Worcester Bosch says to allow two to three minutes.
Why is my Worcester Bosch reset button flashing?
A flashing reset button, often with a flashing power light and a code on the display, means the boiler has locked out. Check the pressure, gas and condensate, then press reset.
Is it safe to reset a Worcester Bosch boiler?
Yes. Pressing reset is one of the things a homeowner can safely do, and it is in the user instructions. The unsafe part is repeating it over and over, or opening the boiler to try to fix it.
Do you work on Worcester Bosch boilers?
Yes. We repair and service all the major brands, including Worcester Bosch. Our engineers are Gas Safe registered and our vans are fully stocked.
When to call an engineer
If your Worcester Bosch boiler will not stay running after two or three resets, or the same code keeps returning, it needs an engineer. We repair and service Worcester Bosch boilers across Hertfordshire, Bedfordshire and Cambridgeshire, we are Gas Safe registered (956889), and our phone is answered 24 hours a day. Book a boiler repair or call 01462 506374.
Need help today?
Call and speak to a person, any hour, any day of the year, or get a fixed price quote online.
Get a fixed price quote Call 01462 506 374Rather have an engineer look at it?
Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374