How to Reset an Ideal Boiler (and When Not To)

Hertfordshire, Bedfordshire & Cambridgeshire

Fully Stocked Vans12 Month Labour GuaranteeGas Safe Registered 956889

To reset an Ideal boiler, press the restart button (on newer models such as the Logic+, Logic Max and Vogue Max it sits under the display) or, on older dial models, turn the mode knob to the reset position and back; if the display shows LC or “Too Many Restarts”, switch the boiler off at the fused spur for about a minute instead. A reset only helps after a one-off lockout, so fix the cause first (low pressure, no gas, a frozen condensate pipe) and do not reset more than once or twice before calling a Gas Safe engineer.

In short

  • Newer Ideal boilers: press the restart button below the display, or use the menu.
  • Older Ideal boilers with a mode knob: turn it to the reset position, then back to your setting.
  • Ideal limits resets. Five in 15 minutes locks the boiler out with LC or “Too Many Restarts”.
  • LC is cleared by switching off at the fused spur, not by pressing restart again.
  • Check the pressure, gas supply and condensate pipe before you reset, or the fault will come straight back.
Ideal boiler installed by Vantage in a fitted cupboard, with copper pipework and a magnetic system filter
An Ideal boiler we fitted in a kitchen cupboard, with a magnetic system filter on the return.

New boiler?

Get an instant estimate for a new boiler

Answer a few questions about your home online and see your estimate straight away, fitted by our own engineers.

Instant boiler estimateOr call 01462 506 374

What a reset actually does

Most Ideal fault codes that start with L are lockouts. The boiler has shut itself down because a safety check failed, for example it could not light the burner or the water got too hot, and it stays off until a person restarts it. That is deliberate: it makes sure someone notices the problem.

Pressing restart tells the boiler to clear the lockout and run its start-up sequence again. Ideal’s own wording on the Logic Combi ESP1 is that pressing restart “will prompt your boiler to repeat its ignition sequence”. If the cause was a one-off, such as a brief interruption to the gas, the boiler lights and carries on. If the cause is still there, it locks out again, and that is when our boiler repair engineers need to find the fault.

Codes that start with F are usually faults that clear themselves once the condition goes away. Low pressure (F1) is the common example: top the system up and the boiler normally starts again, sometimes after a restart.

How to reset each type of Ideal boiler

Ideal has made many ranges over the years and the controls differ. Find yours below, and check your user guide if it looks different.

BoilerHow to resetWhere to look
Logic+, Logic Max, Vogue and Vogue MaxPress the restart button, or restart from the menu on the displayButton below the display
Logic Combi ESP1 and Logic CodePress the restart buttonOn the control panel
Older Logic with a mode knobTurn the mode knob to the reset position, then straight back to your settingMode knob on the front panel
Older Isar HE combiPress the reset button for about 2 secondsFront control panel
Any model showing LC or “Too Many Restarts”Switch off at the fused spur for about a minute, then back onFused spur on the wall near the boiler

Ideal’s user guide for the older Logic combi says to turn the mode control knob to the reset position and immediately turn it back to the required setting. Ideal also notes that on its older boilers, holding the mode dial in the reset position for 3 seconds removes a service reminder, so a quick turn is all a lockout needs.

On the text-screen models, such as the Vogue Max and later Logic Max, a fault appears as a written message rather than a code, and the screen guides you through restarting.

Before you reset: check these first

A reset on its own rarely fixes anything. Do these safe checks first so that when you press restart, the boiler has a chance of staying on.

  1. Read the code. Write down or photograph the code or message. It tells you, and any engineer, what failed.
  2. Check the pressure gauge. Ideal gives 1 to 1.5 bar with the system cold. If it is below 1 bar, top it up with the filling loop as your user guide shows. Our Ideal F1 guide explains how.
  3. Check the gas. Does the hob light? If you have a prepayment meter, check it has credit. Ideal also suggests checking the gas isolation valve under the boiler is open, with the handle in line with the pipe.
  4. Check the condensate pipe in cold weather. If the white plastic pipe outside has frozen, you may hear gurgling from the boiler before it locks out. Thaw it with warm (not boiling) water. See our frozen condensate pipe guide.
  5. Check the power and controls. Make sure the fused spur is on, the timer is calling for heat and the thermostat is turned up.
  6. Now reset once. Use the method for your boiler above. If it lights and stays running, keep an eye on it.
  7. If it locks out again, reset once more at most. If the same code returns, stop and call an engineer.

Stay safe

  • Do not keep pressing restart. Each attempt sends gas to the burner, and repeated lockouts point to a fault that a reset cannot fix.
  • Never remove the boiler casing or try to reach anything inside it. Only a Gas Safe registered engineer may work inside a gas boiler.
  • Do not use boiling water on a frozen condensate pipe. It can crack the plastic.
  • If you smell gas, do not reset the boiler. Call the National Gas Emergency Service on 0800 111 999, open windows and do not use electrical switches.

Why your Ideal boiler will not reset

If the boiler locks out again straight after a reset, the reset has done its job: it has proved the fault is still there. These are the most common reasons we find.

Code or symptomLikely causeCan you fix it yourself?What the engineer does
L2 or F2 after resetNo gas reaching the burner, frozen condensate, worn ignition or flame sensing electrodeGas and condensate checks onlyTests gas pressure, ignition and flame detection
F1 returnsSystem keeps losing pressureTop up, then watch the gaugeFinds the leak, checks the expansion vessel and relief valve
L1 after resetOverheat or no water flow: closed valves, air, a sticking pump or blockageBleed radiators, open valves, check pressureTests the pump and checks flow through the system
F3Fan faultNoTests the fan, its wiring and the control board
L6False flame detectedNoChecks the flame detection electrode, lead and gas valve
Restart button does nothing, LC showingToo many resetsSwitch off at the spurFinds the original fault behind the resets

Our guides to Ideal L2 and the Ideal LC reset lockout go into the two most common in detail. If there is no code at all and the boiler simply will not start, our guide to a boiler not firing up covers the other causes.

LC and “Too Many Restarts”

Ideal boilers count resets. In Ideal’s fault charts for the Logic family, LC is listed as five resets within 15 minutes, and the text-screen models show “Too Many Restarts” for the same limit. Once it appears, the restart button stops working.

To clear it, switch the boiler off at the fused spur (the switched socket or switch next to the boiler), wait about a minute and switch it back on. That clears the lockout, but it does nothing about the fault that made you keep resetting. If the original code comes back, that is the one to deal with.

You may see L5 described as a reset lockout on some websites. On many Ideal boilers L5 is a return sensor fault instead, so check your own user guide before assuming.

Resetting after a power cut

After a power cut, a boiler will usually try to start again on its own once the power returns. If yours shows a lockout, reset it once. Check the clock on any timer or programmer, as a mechanical timer may now be wrong. If the boiler will not restart and the rest of the house has power, check the fused spur and call an engineer.

When to stop and call an engineer

Call a Gas Safe registered engineer if the same code returns after one or two resets, if you see LC, if water is leaking from the boiler, or if the boiler makes unusual noises when it tries to light. We repair and service Ideal boilers, and we are an Ideal Max accredited installer.

If your boiler is still under Ideal’s warranty, contact Ideal first, as repairs arranged through them are usually covered.

What it costs with Vantage

In normal working hours there is no call-out fee. Gas faults start with a fixed-price Gas Safe diagnostic visit, and if we can fix it on the same visit, part of that diagnostic charge comes off the repair. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive.

Frequently asked questions

Where is the reset button on an Ideal boiler?

On current models such as the Logic+, Logic Max and Vogue Max, the restart button is on the control panel just below the display. Older Ideal boilers with a dial have a reset position on the mode knob instead. Your user guide shows the exact layout.

How many times can I reset an Ideal boiler?

Once or twice is reasonable. Ideal’s boilers lock out after five resets in 15 minutes, showing LC or “Too Many Restarts”. If the same fault keeps returning, it needs an engineer.

Why does my Ideal boiler keep needing a reset?

Because the fault behind the lockout has not been fixed. The most common causes are low pressure, a frozen condensate pipe in winter, and a worn ignition or flame sensing part. An engineer can test each one.

Does turning the boiler off and on reset it?

Switching off at the fused spur restarts the controls and is the way Ideal says to clear LC. For an ordinary lockout, use the restart button or reset position first.

Is it safe to reset an Ideal boiler?

Yes, once or twice, as long as you cannot smell gas. The reset button is there for you to use. Repeated resets are not safe, because they keep sending gas to a burner that is not lighting properly.

Ideal boiler repairs in Hertfordshire, Bedfordshire and Cambridgeshire

If your Ideal boiler will not stay on after a reset, our Gas Safe registered engineers (registration 956889) can find out why. We are rated 4.9 on Google and our phone is answered 24 hours a day, 7 days a week, with emergency cover. Visit our boiler repair page or call 01462 506374.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.