Skip to main content

Vantage Plumbing and Heating

How to Set the Timer on a Baxi Boiler: Mechanical, Digital and App

Hertfordshire, Bedfordshire & Cambridgeshire

Fully Stocked Vans12 Month Labour GuaranteeGas Safe Registered 956889

To set a Baxi mechanical timer, turn the outer dial clockwise until the arrow points to the current time, push the tappets to the outer edge for the times you want heating (each tappet is 15 minutes), then set the switch to the timed position. A Baxi digital timer is set with its MENU, OK and plus and minus buttons, and many newer Baxi boilers have no clock on the boiler at all, so the times are set on a separate programmer, thermostat or the My Baxi app.

In short

  • Baxi’s 24 hour mechanical timer: set the time by turning the dial clockwise only, then use the tappets. Tappets at the outer edge mean heating on.
  • The three-position switch gives constant, timed or off. Timed is the one that follows your settings.
  • Baxi’s 7 day digital timer has preset programmes and lets you set on and off times for each day or group of days.
  • On a combi, the timer controls the heating. Hot water still comes on demand.
  • If there is no timer on the boiler, the schedule lives on your programmer, thermostat or the My Baxi app.

New boiler?

Get an instant estimate for a new boiler

Answer a few questions about your home online and see your estimate straight away, fitted by our own engineers.

Instant boiler estimateOr call 01462 506 374

Which Baxi timer do you have?

Baxi has fitted different controls over the years, and it also sells plug-in timers that fit into the front panel of some boilers. Look at the front of your boiler and match it to the table.

What you seeTypeHow it works
A round clock dial with small white tabs around the edge and a three-position switch24 hour mechanical timerEach tab (tappet) switches 15 minutes of heating on or off
A small digital screen with buttons marked MENU, OK, plus and minus7 day digital timerOn and off times programmed for each day
A display with temperature and mode buttons, but no clockBoiler with no built-in timerTimings are set on a separate programmer, room thermostat or smart control
No controls you recogniseCheck the user guideBaxi’s literature library has guides for current and older models

If your heating is controlled by a wall thermostat with its own screen, or by the Baxi uSense smart control, set the schedule there rather than on the boiler. If the controls look right but the boiler will not respond, our boiler repair engineers can test the timer and the boiler together.

How to set a Baxi mechanical timer

These steps follow Baxi’s instructions for its 24 hour electro-mechanical timer, which are the same as those in the user guide for boilers such as the Platinum Combi.

Step 1: set the time of day

  1. Turn the outer dial clockwise until the arrow or pointer lines up with the time now. Baxi says to set it to the nearest 15 minutes.
  2. Check morning and afternoon. The dial runs over 24 hours, so 7 in the morning and 7 in the evening are on opposite sides. Setting it 12 hours out is the most common mistake.
  3. Never turn the dial anticlockwise. Baxi’s instructions are clear on this.

Step 2: set the on and off times with the tappets

Each small white tappet around the dial is worth 15 minutes, so four tappets make an hour.

  1. Push tappets outwards, to the outer edge of the dial, for every 15 minutes you want the heating on.
  2. Push tappets inwards, towards the centre, for the times you want it off.
  3. Work round the whole dial. For heating from 6.30 to 8.30 in the morning, for example, push out the eight tappets between those times and make sure the tappets either side are pushed in.

Some timers from other manufacturers work the other way round, so if the heating comes on at exactly the wrong times, check the direction in your user guide.

Step 3: set the switch

The three-position switch next to the dial decides whether the timer is used at all.

Switch positionWhat happens
Constant (top)Heating is on all the time, controlled only by the thermostat. The tappets are ignored
Timed (centre)Heating follows the tappets
Off (bottom)No central heating. On a combi, hot water still works when you run a tap

Most people leave it on timed. Constant is handy during a cold snap or if you are ill at home. Off is for summer.

How to set a Baxi 7 day digital timer

Baxi’s integral 7 day electronic timer uses four main buttons: MENU, OK, plus and minus. There is also a small Res (reset) button you press with a pencil point, and a +1h button for the clock change. Exact screens vary a little between versions, so keep your instructions to hand.

Setting the time and day

  1. Press MENU and choose the clock setting.
  2. Choose 24 hour or AM/PM display, then confirm with OK.
  3. Set the hour and then the minutes with plus and minus, pressing OK after each.
  4. Set the day. The timer numbers the days 1 to 7, with 1 as Monday and 7 as Sunday.

Setting the heating times

  1. Choose a preset or your own programme. Baxi’s timer has three preset programmes, P01 to P03, or you can build your own.
  2. Choose the days. You can set the same times for all seven days, Monday to Saturday, Monday to Friday, the weekend only, or any single day.
  3. Set the on time, then the off time. Baxi’s timer works in pairs, so every on time has a matching off time on the same day or group of days.
  4. Add another pair if you want the heating on twice a day, such as morning and evening.
  5. Press OK to save, then return to the normal display.

Override, power cuts and the clock change

  • Override: pressing plus in normal operation overrides the programme. If the heating is on, it goes off, and if it is off, it comes on, until the next programmed change.
  • Power cuts: Baxi says the timer’s built-in battery keeps the time and the programme running during a mains power cut.
  • Clock change: the +1h button adds or removes the summer hour, as your instructions show.

Changing the clocks on a mechanical timer

A mechanical timer does not know about British Summer Time, and because it runs on mains power it will lose time during a power cut too.

  • When the clocks go forward in March, turn the dial clockwise by one hour.
  • When the clocks go back in October, you cannot turn the dial backwards. Turn it clockwise by 23 hours instead, which brings it to the right time.

After any power cut, check the dial against the time and correct it.

Setting the schedule in the My Baxi app

If your Baxi boiler is controlled by the Baxi uSense smart control, the schedule lives in the My Baxi app rather than on the boiler. Baxi’s instructions are to tap More at the bottom of the screen, select Schedules, then tap the arrow next to Zones. From there you can view each day, change the time and temperature of each block and copy the pattern to other days.

If you would like app control and your current Baxi has only a basic timer, a smart thermostat can usually be added. Our smart thermostat installation page explains what is involved.

Why is my heating ignoring the timer?

If the heating does not come on at the times you set, work through these checks in order.

  1. Is the switch on timed? If it is on off, nothing will happen. If it is on constant, the timer is ignored.
  2. Is the time right? A mechanical dial 12 hours out, or one that stopped during a power cut, is the most common cause.
  3. Are the tappets the right way round? Outer edge is on for Baxi’s own timer.
  4. Is the thermostat turned up? The timer only allows heating. The room thermostat must also be calling for heat, and the radiator valves must be open.
  5. Is there another controller? Some homes have a wall programmer as well as a timer on the boiler. Both have to allow heating for it to come on. Leaving the boiler timer on constant and using the wall programmer avoids the conflict.
  6. Is the boiler showing a fault? A code on the display means the boiler cannot run, whatever the timer says. On many Baxi boilers, a failed ignition shows as E133, which our Baxi E133 guide explains.

If the heating comes on but some radiators stay cold, the timer is working and the problem is in the system. Our guide to a radiator not heating up covers the usual causes. If you have heating but no hot water, see no hot water but heating works.

Safe to do, and not safe to do

  • Setting the timer, the switch and the thermostat is always safe for you to do.
  • Replacing a plug-in timer involves the boiler’s electrical connections and should be done with the power isolated by someone competent. Do not open the boiler casing.
  • If the timer is dead or the boiler shows no signs of life, check the fused spur before anything else.
  • If you smell gas, call the National Gas Emergency Service on 0800 111 999.

When the timer itself has failed

Mechanical timers wear out. The motor can stop, the dial can slip, or tappets can break off. A digital timer can lose its display or stop switching. Signs include a dial that does not move, a clock that gains or loses time, or heating that does not switch on or off even though every setting is right.

A faulty timer is a straightforward part to replace, but it is worth having an engineer confirm that the timer really is the problem, because a fault in the boiler’s control board or wiring can look the same. We repair and service all the major brands, including Baxi.

What it costs with Vantage

In normal working hours there is no call-out fee. Gas faults start with a fixed-price Gas Safe diagnostic visit, and if we can fix it on the same visit, part of that diagnostic charge comes off the repair. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive.

Frequently asked questions

Do the tappets go in or out for on?

On Baxi’s own mechanical timer, a tappet pushed to the outer edge of the dial means the heating is on for that 15 minutes, and pushed in towards the centre means off. If your timer behaves the opposite way, check the user guide, as some other makes work in reverse.

Does the Baxi timer control the hot water on a combi?

No. On a combi, the timer controls the central heating. Hot water is heated on demand whenever you turn on a hot tap, even with the timer switch on off.

Why is my Baxi timer running slow or stopped?

A mechanical timer stops whenever the power is off, so it will be behind after a power cut. If it keeps losing time with the power on, the motor is failing and the timer needs replacing.

How do I turn off the timer and have the heating on all the time?

Move the three-position switch to constant, the top position. The heating then runs whenever the room thermostat asks for heat, and the tappets are ignored.

Can I add a smart thermostat to a Baxi boiler?

In most cases, yes. Baxi’s own uSense control works with the My Baxi app, and other smart thermostats can be fitted too. An engineer will check which controls suit your boiler and system.

Heating help in Hertfordshire, Bedfordshire and Cambridgeshire

If your Baxi timer or controls have stopped working, or your boiler will not respond to them, our Gas Safe registered engineers (registration 956889) can help. We are rated 4.9 on Google and our phone is answered 24 hours a day, 7 days a week. See our boiler repair page or call 01462 506374.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.