Common Ideal Isar Boiler Problems and What Causes Them
Hertfordshire, Bedfordshire & Cambridgeshire
The most common Ideal Isar problems are the boiler failing to light (L and F alternating on the display), overheating (L and A), losing pressure, weak or fluctuating hot water, and noise from the heat exchanger or pump. Some have simple causes you can check yourself, such as low pressure or a frozen condensate pipe, but most point to a worn part inside the boiler that needs a Gas Safe engineer, and on an Isar of this age it is worth weighing each repair against replacement.
In short
- The Isar HE is an older Ideal combi. Its display shows two characters that alternate when there is a fault.
- L and F together mean the boiler failed to light. Check the gas and the condensate pipe, then press reset for 2 seconds.
- L and A together mean it overheated. Check the pressure is 1 to 1.5 bar and bleed the radiators.
- Poor hot water in Hertfordshire is often limescale in the hot water heat exchanger.
- Repeated faults on an older Isar are the point to compare the repair with a new boiler.

New boiler?
Get an instant estimate for a new boiler
Answer a few questions about your home online and see your estimate straight away, fitted by our own engineers.
About the Ideal Isar
The Isar HE is a combination boiler from Ideal, made in 24, 30 and 35 kW versions. It heats the radiators through its main heat exchanger and makes hot water on demand through a second, smaller plate heat exchanger, with a diverter valve switching between the two. It is not part of Ideal’s current range, so most Isars still running are well into their working life. We repair and service all the major brands, and our boiler repair engineers can diagnose older Ideal models like this one.
The display is simple. In normal running it shows 0 for standby, C when heating is on and d when hot water is being made. When something goes wrong it shows two characters one after the other, such as L then F. Ideal’s user guide and installation manual list what each pair means, and those are the codes used in this guide.
If your Isar shows a code in a different format, such as F1 or L2, you may have a different generation or a different Ideal model, so check the user guide for your boiler.
Problem 1: the boiler will not light (L and F)
This is one of the most common faults on the Isar. Ideal’s user guide describes L and F as the boiler failing to ignite, and the installation manual treats it as a flame detection fault. The boiler tried to light, did not detect a flame and locked out.
What you can check
- Gas supply. Does the hob light? If you have a prepayment meter, does it have credit?
- Condensate pipe. Ideal’s troubleshooting advice for the Isar is to check the condensate pipe is not blocked or frozen. In freezing weather, thaw it with warm, not boiling, water. Our frozen condensate pipe guide shows how.
- Reset. Press the reset button for 2 seconds, as the user guide says. This repeats the ignition sequence.
If it locks out again, the cause is inside the boiler. Ideal’s fault-finding chart for this code takes the engineer through the spark generator, the ignition electrode, the flame detection electrode and their leads, the gas valve and the control board.
Problem 2: the boiler overheats (L and A)
L and A together mean the boiler has overheated and locked out. It is usually a water problem: the water in the boiler got too hot because it was not moving through the system fast enough.
What you can check
- Pressure. The gauge should read between 1 and 1.5 bar with the system cold. Top up with the filling loop if it is low.
- Radiators. Bleed any that are cold at the top, then check the pressure again.
- Valves. Make sure the radiator valves are open.
- Reset for 2 seconds once the system has cooled.
If L and A comes back, the engineer checks the system is full and circulating, tests the pump, and then works through the temperature sensor and the overheat thermostat, which is how Ideal’s manual approaches it. Sludge in an older system is a common underlying cause.
Problem 3: losing pressure
An Isar that needs topping up every few weeks has water leaving the system, or an expansion vessel that no longer absorbs the extra volume when the water heats up. Low pressure then leads to overheating and lockouts.
| Cause | What you might notice | Can you fix it yourself? | What the engineer does |
|---|---|---|---|
| Leak on a radiator, valve or joint | Drips, stains or crusting | Sometimes, if a visible fitting is loose | Finds and repairs the leak |
| Pressure relief valve letting by | Water from the small pipe outside | No | Replaces the valve |
| Expansion vessel lost its charge | Pressure high when hot, low when cold | No | Recharges or replaces the vessel |
| Internal boiler leak | Water under the boiler | No | Finds the leak inside the case |
Our guide to a boiler that keeps losing pressure explains each cause in more detail.
Problem 4: hot water that is weak, lukewarm or fluctuating
Hot water problems on an Isar usually come from one of three places.
- Limescale in the plate heat exchanger. Hard water, which covers most of Hertfordshire, leaves scale in the small channels that heat your tap water. The result is hot water that takes longer to warm up, runs lukewarm or swings between hot and cold. The engineer can descale or replace the plate heat exchanger.
- The diverter valve. If it sticks, you may get heating but no hot water, or hot water that is only warm because some of the heat is going to the radiators.
- The hot water sensor. Ideal’s user guide lists H and 3 as a hot water thermistor error. The sensor or its wiring needs testing.
If you have heating but no hot water at all, our guide to no hot water but heating works covers the checks.
Problem 5: banging, kettling or gurgling
A boiler that bangs or rumbles like a kettle while it heats usually has scale or sludge restricting the flow through its heat exchanger, so the water boils in spots. Air in the system and a failing pump cause similar noises. Gurgling just before a lockout in winter points to a frozen condensate pipe.
Bleeding the radiators and checking the pressure is worth doing. After that, noise needs an engineer, and on an older system a clean of the system water is often part of the fix. Our guide to a boiler making a banging noise goes through the causes.
Problem 6: no display or no power
If the display is blank, first check the fused spur next to the boiler is switched on and that the rest of the house has power. If it has, and the boiler still shows nothing, the fault is likely to be the control board or its fuse, which needs an engineer.
Other codes on the Isar
Ideal’s installation manual lists several other alternating codes on the Isar HE. They all point to parts inside the boiler, such as the fan, the control board or the temperature sensors. There is nothing for a homeowner to do beyond one reset, so note the code and call an engineer.
What not to do
- Do not keep pressing reset. If the same code returns after one or two resets, the fault needs finding.
- Never remove the boiler casing or touch anything inside. Only a Gas Safe registered engineer may work on a gas boiler.
- Do not pour boiling water on a frozen condensate pipe.
- If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows and do not use electrical switches.
Repair or replace an Ideal Isar?
Many Isar faults are routine repairs: an electrode, a sensor, a pump or an expansion vessel. A single repair on a boiler that has otherwise been reliable is usually worth doing.
Replacement becomes the better choice when:
- the boiler has had several different faults in a short space of time
- the repair needs an expensive part, such as the main heat exchanger or the control board
- the system is full of sludge and the boiler is struggling
- you want lower running costs and a long warranty
Our guide to boiler repair versus replacement explains how we help customers decide. We will always tell you honestly whether a repair makes sense.
What it costs with Vantage
In normal working hours there is no call-out fee. Gas faults start with a fixed-price Gas Safe diagnostic visit, and if we can fix it on the same visit, part of that diagnostic charge comes off the repair. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive.
If you decide to replace it, new boilers are quoted as a fixed price after a free survey.
Frequently asked questions
Are Ideal Isar boilers reliable?
Many Isars are still running. Like any boiler of its age, it is now more likely to need parts, and how well it has been serviced and how clean the system is make a big difference.
How do I reset an Ideal Isar boiler?
Press the reset button for 2 seconds, as Ideal’s user guide says. Check the pressure, gas and condensate pipe first, and do not reset more than once or twice if the same fault returns.
What pressure should an Ideal Isar be?
Between 1 and 1.5 bar with the system cold. Below 1 bar, top it up with the filling loop and then switch the boiler off and on again.
Why does my Ideal Isar keep locking out in cold weather?
The most common reason is a frozen condensate pipe, which stops the boiler lighting. Thaw it with warm water and reset. If it keeps freezing, an engineer can insulate or reroute the pipe.
Is it worth repairing an old Ideal Isar?
Often, for a single routine fault. If it has had several faults recently or needs a major part, replacement is usually better value over the next few years.
Ideal boiler repairs in Hertfordshire, Bedfordshire and Cambridgeshire
If your Ideal Isar keeps locking out or losing pressure, our Gas Safe registered engineers (registration 956889) can diagnose it and give you an honest view on repair or replacement. We are rated 4.9 on Google and our phone is answered 24 hours a day, 7 days a week. See our boiler repair page or call 01462 506374.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374