Common Navien Boiler Problems, Fault Codes and How to Reset a Navien Boiler
Hertfordshire, Bedfordshire & Cambridgeshire
The most common Navien boiler problems are low system pressure (fault code E302), the boiler failing to light or losing its flame (E003 and E012), a blocked condensate or flue (E110) and overheating (E001 or E016). Low pressure and a frozen condensate pipe are things you can often sort out yourself, and many other codes clear with a single reset, but a code that keeps coming back needs a Gas Safe engineer, or an oil engineer for the LCB700 oil combi.
In short
- E302 means the heating pressure has dropped below 1 bar. Top it up to between 1 and 1.2 bar using the filling link or loop.
- E003 is ignition failure and E012 is flame loss. Check the gas or oil supply, then reset once.
- E110 points to a blocked exhaust or condensate, often a frozen condensate pipe in winter.
- Some codes clear themselves. Others need a manual reset from the front panel, as shown in your user manual.
- If a code returns after one or two resets, stop and call an engineer.

New boiler?
Get an instant estimate for a new boiler
Answer a few questions about your home online and see your estimate straight away, fitted by our own engineers.
Navien boilers in the UK
Navien’s UK range includes the NCB-CE, NCB300, NCB500 and NCB700 gas combi boilers and the LCB700, an oil-fired combi. They share a similar display and a common set of fault codes, shown as an E followed by three digits. The codes below are taken from Navien’s own user information for the NCB700 range, checked against published fault code lists. Some codes differ slightly between models, so always check the manual for your boiler.
If your Navien has stopped and you would rather have it looked at, our boiler repair engineers repair and service all the major makes, including Navien.
How to reset a Navien boiler
Navien codes fall into two groups. Some reset automatically once the cause has gone, for example low pressure once you have topped the system up. Others lock the boiler out until someone resets it manually.
- Note the code on the display before you do anything. The engineer will want it.
- Deal with the obvious cause first: top up the pressure, thaw the condensate pipe, check the gas or oil supply.
- Reset once using the reset function on the front panel. Your user manual shows the button for your model.
- Wait for the boiler to try again. It may take a minute or so to run through its start-up checks.
- If the code comes back, stop. Navien’s own guidance is that if resetting does not clear the fault, or it happens repeatedly, you should contact Navien or a Gas Safe registered engineer.
What not to do
- Do not keep resetting a boiler that locks out again. Repeated attempts will not fix the fault.
- Do not remove the casing or touch the gas valve, fan, burner, PCB, heat exchanger or flue. Only a Gas Safe registered engineer may work inside a gas boiler.
- On an LCB700, do not try to bleed the oil pump or adjust the burner.
- Do not raise the pressure above 1.5 bar when topping up.
- If you smell gas, turn off the supply at the meter if it is safe, open windows, do not use switches and call the National Gas Emergency Service on 0800 111 999.
Common Navien fault codes
| Code | What it means | Can you fix it yourself? | What the engineer does |
|---|---|---|---|
| E302 | Low water pressure in the heating system | Yes, top up to 1 to 1.2 bar | Finds the leak or failed part if the pressure keeps dropping |
| E352 | High water pressure | Bleed a radiator to bring it down to about 1 to 1.2 bar | Checks the expansion vessel, filling link and pressure relief valve |
| E003 | Ignition failure, the boiler could not light | Check the gas or oil supply, reset once | Checks the gas or oil supply, ignition, electrode and burner |
| E012 | Flame loss after lighting | Check the supply, reset once | Checks gas pressure, flame sensing, flue and condensate |
| E110 | Exhaust blockage, often condensate blockage | Thaw a frozen condensate pipe, reset once | Clears the condensate trap and pipe, checks the flue |
| E001 or E016 | Heat exchanger overheating | Check radiator valves are open and the pressure is right, reset once | Checks the pump, circulation, filters and sensors |
| E030 | Abnormal exhaust temperature | No | Checks the flue, heat exchanger and sensors |
| E109 | Fan fault | No | Tests and replaces the fan or wiring |
| E205, E218 | Heating flow or return sensor fault | No | Tests and replaces the sensor |
| E407, E421 | Hot water outlet or inlet sensor fault | No | Tests and replaces the sensor |
| E515, E517, E594, E615 | Control board faults | No | Diagnoses and repairs or replaces the PCB |
| E740 | Outdoor temperature sensor fault | No | Checks the outdoor sensor and wiring |
| E782 | Main panel communication fault | No | Checks the display panel and connections |
E302: low pressure
This is the Navien code homeowners see most. Navien says E302 means the system pressure has dropped below 1 bar. How you top it up depends on the model, according to Navien’s own instructions:
- NCB500 and NCB700: find the NaviFill Link under the boiler, a link with a green lever. Pull the lever slowly until the pressure reaches 1 to 1.2 bar, then let go.
- LCB700: find the braided filling loop near the top right with two black tap handles. Open each a quarter turn until the pressure reaches 1 to 1.2 bar, then close both.
- NCB-CE and NCB300: find the braided filling loop under the boiler with a blue and a black tap handle. Open the black tap, then slowly open the blue tap until the pressure reaches 1 to 1.2 bar, then close both.
Do not go above 1.5 bar. If you overfill, bleed a radiator to bring the pressure back down. If you have to top up more than once every few weeks, water is escaping somewhere. Our guide to a boiler that keeps losing pressure explains the usual causes.
E003 and E012: ignition failure and flame loss
E003 means the boiler tried to light and could not detect a flame. E012 means it lit and then lost the flame. Before calling anyone:
- Check other gas appliances, such as the hob, are working. If none are, the problem is the gas supply.
- If you have a prepayment meter, check it has credit.
- On an LCB700, check there is oil in the tank and that the tank valve is open.
- In freezing weather, check the condensate pipe, as a blockage can stop the boiler lighting.
- Reset once.
If the code comes back, the likely causes are inside the boiler: the ignition electrode, gas valve, flame sensing or, on the oil model, the burner nozzle and oil pump. That needs an engineer. Our guide to a boiler not firing up covers the checks that apply to any make.
E110: exhaust or condensate blockage
Navien lists E110 as an exhaust blockage, including a condensate blockage. In winter the usual cause is a frozen condensate pipe outside. Pour warm, not boiling, water over the outside section, then reset the boiler once. Our frozen condensate pipe guide shows how to find and thaw it. If it is not frozen, the condensate trap or the flue may be blocked, and that needs an engineer.
Overheating: E001 and E016
These codes mean the heat exchanger has got too hot, usually because water is not moving through the boiler fast enough. Check the pressure is between 1 and 1.5 bar and that radiator valves are open, then reset once. If it returns, an engineer will check the pump, any blocked filters, sludge in the system and the temperature sensors.
Other Navien problems without a code
No hot water. Check the hot water setting on the panel and that the isolating valves under the boiler are fully open. A combi needs a certain flow at the tap before it fires, so turn the hot tap on fully. If the heating works but not the hot water, see our guide to no hot water but heating works.
Heating comes on at night or when it is off. Navien says this is often the minimum room temperature setting on its Smart Plus controller. If it is set high, the boiler will run to keep the room at that temperature during off periods. Navien boilers also have built-in frost protection that runs the boiler and pump if the water inside drops below 10°C.
Radiators not getting hot. Air, sludge or a blocked filter reduce circulation. Bleed any radiators that are cool at the top.
Repair or replace?
Most Navien faults are repairs: a sensor, an electrode, a fan or a cleaned trap. Replacement is worth considering if the boiler is old, needs a major part such as a heat exchanger or control board and is out of guarantee, or keeps breaking down. Navien requires yearly servicing by a competent engineer to keep its warranty valid, so keep your service records.
What it costs with Vantage
In normal working hours there is no call-out fee. Gas faults start with a fixed-price Gas Safe diagnostic visit, and if we can fix it on the same visit, part of that diagnostic charge comes off the repair. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive.
Frequently asked questions
How do I reset my Navien boiler?
Fix the obvious cause first, such as low pressure, then use the reset function on the front panel as shown in your user manual. Reset once and let the boiler try again. If the same code returns, call an engineer.
What pressure should a Navien boiler be?
Navien says to top the system up to between 1 and 1.2 bar when it is cold, and not to go above 1.5 bar. E302 shows when it drops below 1 bar.
Why does my Navien boiler keep losing pressure?
Water is escaping from the sealed system, usually through a small leak, a weeping radiator valve, the pressure relief valve or a failed expansion vessel. Topping up is a temporary fix. An engineer needs to find where the water is going.
Does a Navien boiler need servicing every year?
Yes. Navien requires the boiler to be serviced yearly by a competent engineer, and says failing to do so will invalidate the warranty. Annual servicing also keeps the condensate trap and filters clear.
Can any engineer repair a Navien boiler?
A Gas Safe registered engineer can repair Navien gas boilers, and the LCB700 oil combi needs an engineer trained in oil firing. We repair and service all makes, including Navien.
When to call an engineer
If a Navien fault code comes back after a reset, the pressure keeps falling, or you see water or smell fumes, it is time for an engineer. We cover Hertfordshire, Bedfordshire and Cambridgeshire from our Stevenage base. Book through our boiler repair page or call 01462 506374, answered 24 hours a day, 7 days a week.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374