If your boiler has no power (a blank display, no lights and no response to the controls), the cause is usually outside the boiler: a power cut, the fused spur switched off, a blown fuse in that spur, or a tripped switch at the consumer unit. You can check all of those safely yourself, but if power is reaching the boiler and it still stays dead, or the electrics trip every time it is switched on, the fault is inside the boiler and needs a Gas Safe registered engineer.

In short

  • Every modern gas boiler needs electricity for its controls, fan, pump and ignition, so no power means no heating and no hot water.
  • Check for a power cut, then the boiler’s own switch, the fused spur next to it and the consumer unit.
  • A blown fuse in the spur is common. Replace it with the same rating, and if it blows again, leave it off.
  • If a switch at the consumer unit trips again as soon as you reset it, there is a fault. Leave it off and get it looked at.
  • Internal fuses, the control board and wiring inside the case are jobs for a Gas Safe engineer only.
Ideal boiler installed by Vantage in a fitted cupboard, with copper pipework and a magnetic system filter
One of our boiler installations: an Ideal combi in a fitted cupboard with a magnetic system filter.

New boiler?

Get an instant estimate for a new boiler

Answer a few questions about your home online and see your estimate straight away, fitted by our own engineers.

Instant boiler estimateOr call 01462 506 374

First, what exactly are you seeing?

“No power” can mean slightly different things, and each one points somewhere different.

What you seeMost likely cause
Boiler dead and other lights or sockets off tooPower cut, or a main switch or RCD tripped at the consumer unit
Boiler dead, everything else in the house workingFused spur off, blown spur fuse, the boiler’s own switch off, or a circuit breaker for the heating tripped
Boiler dead and the heating timer or programmer dead tooThe supply to the whole heating system, often the same fused spur
Power returns, but the electrics trip when the boiler startsA fault in the boiler or its wiring, sometimes water reaching electrical parts
Spur has power, fuse is fine, boiler still deadA fault inside the boiler: internal fuse, control board or wiring
Display lit but boiler will not fireNot a power problem. See our guide to a boiler not firing up

If you would rather not work through it, our boiler repair service covers all the major brands and the phone is answered 24 hours a day, 7 days a week.

Check these first

Work through these in order. They are all safe for a homeowner and none of them involve opening the boiler.

  1. Is it a power cut? Try a light and a socket. If nothing works, check whether your neighbours have power. In Great Britain you can call 105 free to report or check a power cut with your local network operator.
  2. The boiler’s own switch. Many boilers have an on/off button or dial on the front. Check it has not been knocked off.
  3. The fused spur. Boilers are normally wired through a switched fused connection unit, usually on the wall near the boiler. Make sure the switch is on. Many have a small indicator light that shows when power is getting through.
  4. The fuse in the spur. If the spur has a fuse carrier, switch it off, pull out the carrier and check the fuse, or simply swap it for a new one of the same rating. Manufacturers such as Ideal specify a 3A fuse for their boilers, and your installation manual will say. If the new fuse blows as soon as the boiler starts, stop. There is a fault that needs finding.
  5. The consumer unit. Look for a circuit breaker or RCD that has tripped (it will sit in a different position from the rest). Reset it once. If it trips again straight away, or trips when the boiler starts up, leave it off.
  6. The controls. If the boiler has power but nothing happens, check the timer and thermostat. After a power cut, clocks often reset, and wireless thermostats and smart hubs may need to reconnect. Replace thermostat batteries if the display is weak or blank.
  7. Reset once power is back. Some boilers come back with a fault showing after a cut. Press reset as your user guide describes, once or twice at most.

What not to do

  • Do not remove the boiler casing or look for fuses on the control board. Under the Gas Safety (Installation and Use) Regulations 1998 only a Gas Safe registered engineer may work on a gas appliance, and the inside of the boiler carries mains voltage.
  • Do not fit a higher-rated fuse to stop a fuse blowing. The fuse is protecting the boiler and its wiring.
  • Do not keep resetting a switch that trips. Repeated tripping means a fault, and it can be water getting into the electrics from a leak.
  • If you see water dripping onto or out of the boiler and the electrics are tripping, leave the power off at the spur and call an engineer.
  • If you smell gas, call the National Gas Emergency Service on 0800 111 999, open doors and windows, do not use electrical switches or naked flames, and turn the gas off at the meter if it is safe to do so.

Common causes

CauseWhat you might noticeCan you fix it yourself?What the engineer does
Power cutWhole house or street offWait for it to come back, then reset the boilerNothing needed unless the boiler stays dead afterwards
Fused spur switched offEverything else works, spur light offYes, switch it back onNothing needed
Blown spur fuseSpur on but no power to the boilerYes, replace with the same rating onceFinds out why it blew if it happens again
Tripped breaker or RCDOne switch down at the consumer unitReset once onlyTests the boiler and wiring for the fault causing the trip
Leak reaching electrical partsTripping, water inside or under the boilerNo, leave the power offFinds and fixes the leak, dries and tests the electrics
Blown internal fusePower at the spur, boiler still deadNoTests the fuse and finds the cause before replacing it
Failed control board or displayPower reaching the boiler but no display or responseNoTests the board and replaces it if it has failed
Damage after a power surgeBoiler dead after a storm or supply faultNoTests the board and components for damage
Loose or damaged wiringIntermittent loss of power, burning smellNoMakes the wiring safe and repairs it

What an engineer will check

A Gas Safe engineer will normally:

  • Isolate the boiler safely and confirm whether mains voltage is reaching the spur and the boiler’s terminals.
  • Check the wiring between the spur, the boiler and the controls, including any wiring centre for the heating system.
  • Test the boiler’s internal fuses, and if one has blown, find what blew it before fitting a new one.
  • Look for water leaks inside the case that could be reaching electrical parts.
  • Test the control board, display and other electrical parts.
  • Once power is restored, run the boiler through heating and hot water and check it is working safely.

If the problem is clearly in the house wiring rather than the boiler, for example a circuit that keeps tripping with the boiler disconnected, an electrician is the right person for that part. Our electrical fault finding service covers that.

Frost risk while the boiler is off

Modern boilers have frost protection, but it only works while the boiler has power. Ideal’s user guides, for example, make the point that frost protection depends on the power supply staying on. If your boiler loses power in freezing weather, get it back on as soon as you can. If the boiler also shows a fault in cold weather after the power returns, check the condensate pipe outside, as described in our frozen condensate pipe guide.

Repair or replace?

Most “no power” call-outs are simple: a fuse, a switch or a tripped circuit. When the fault is inside the boiler, the usual repair is a fuse or a control board. A board is one of the dearer parts, so on an older boiler that has had several recent repairs, it is worth weighing up a replacement. We will give you an honest view and a quoted price before any work goes ahead.

What it costs with Vantage

In normal working hours there is no call-out fee. Gas faults start with a fixed-price Gas Safe diagnostic visit, and if we can fix it on the same visit, part of that diagnostic charge comes off the repair. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive.

Frequently asked questions

Will my boiler work without electricity?

No. A modern gas boiler needs electricity to run its controls, fan, pump and ignition, so during a power cut you will have no heating and no hot water from it. Once power returns, most boilers restart on their own, although some need a reset.

What fuse does a boiler need?

Most boilers are supplied through a fused spur, and manufacturers such as Ideal specify a 3A fuse. Check the rating on the old fuse or in your boiler manual and always replace like for like. Never fit a bigger fuse to stop one blowing.

Why has my boiler lost power after a power cut?

The boiler may have locked out when the power dropped, the clock on the timer may have reset, or a surge when the supply came back may have tripped a switch or damaged a part. Check the consumer unit, the fused spur and the timer settings, then reset once. If it stays dead with power at the spur, call an engineer.

Why does my boiler keep tripping the electrics?

A boiler that trips the RCD or a breaker has a fault somewhere in the boiler, its wiring or its controls. A water leak reaching electrical parts is a common cause. Leave the power off at the spur and have a Gas Safe engineer find the fault.

Can an electrician fix a boiler with no power?

An electrician can check the supply up to the boiler, including the circuit, the spur and the wiring to the heating controls. Anything inside the boiler case, including its internal fuses and control board, must be dealt with by a Gas Safe registered engineer.

When to call an engineer

If the power is reaching the boiler and it still stays dead, a fuse keeps blowing, or the electrics trip whenever the boiler starts, it needs a Gas Safe engineer. We are Gas Safe registered (956889), based in Stevenage, and cover Hertfordshire, Bedfordshire and Cambridgeshire, with 24/7 emergency cover. Book through our boiler repair page or call 01462 506374.

Need help today?

Call and speak to a person, any hour, any day of the year, or get a fixed price quote online.

Get a fixed price quote Call 01462 506 374
Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.