Oil Boiler Not Firing Up: Causes and What to Check
Hertfordshire, Bedfordshire & Cambridgeshire
If your oil boiler is not firing up, the most common reasons are simple: the tank has run low or empty, the power or controls are not calling for heat, or the burner has gone into lockout after a failed start. Check the oil level, the power and the timer, then press the burner reset button once, but no more than twice in total, and if it still will not fire, the burner needs an oil-trained engineer.
In short
- Check the oil level first. Gauges can stick, so look in the tank if it is safe to do so.
- Check the power, the fused spur, the timer and the thermostat.
- A red light on the burner usually means lockout. OFTEC’s advice is never to reset a burner more than twice.
- After running out of oil, the burner often needs bleeding and the filter checking before it will run.
- Nozzles, electrodes, the photocell, the fuel pump and the control box are engineer jobs.

How an oil boiler fires
Most oil boilers in UK homes use a pressure jet burner. When the controls call for heat, the burner motor spins a fan and a fuel pump. The pump pushes kerosene through a fine nozzle, which turns it into a mist. A pair of electrodes creates a spark to light it, and a photocell (a light sensor) watches for the flame. If the photocell does not see a flame within a few seconds, the control box shuts the burner down and puts it into lockout, usually shown by a red light on the burner.
That lockout is a safety feature. If the burner kept pumping oil without lighting it, unburnt oil would collect in the combustion chamber. So “not firing up” can mean two different things: nothing happens at all, which points to the supply, power or controls, or the burner runs and then locks out, which points to fuel delivery, ignition or flame detection. If your boiler runs on gas rather than oil, our guide to a gas boiler not firing up covers the checks for that instead.
Check these first
These checks do not involve tools, electrics or working at height, and they match the troubleshooting advice from OFTEC, the oil heating trade body.
- Check the oil level. Look at the tank gauge. If you are not sure it is accurate and it is safe to do so, remove the fill cap and look inside, or dip the tank with a long cane. Gauges do stick.
- Check the power. Make sure the fused spur for the boiler is switched on and the fuse has not blown. Check the consumer unit for a tripped switch.
- Check the controls. Make sure the programmer or timer shows the correct time and is in an “on” period, and turn the room thermostat up above room temperature. After a power cut, timers can reset.
- Look for a lockout light. A red light on the burner usually means it has tried to start and failed.
- Reset once. Press the burner reset button once and wait. If it fires and runs, keep an eye on it. OFTEC’s guidance is that a burner reset should never be attempted more than twice.
- Check the condensate pipe on a condensing boiler. In freezing weather, a frozen condensate pipe can stop a condensing oil boiler, just as it does a gas one. Our guide to a frozen condensate pipe shows how to thaw it safely with warm, not boiling, water.
If the burner locks out again, stop resetting and call an engineer. Our boiler repair page explains how we handle breakdowns, and you can call us to talk through what you are seeing.
What not to do
- Do not reset the burner more than twice. Each failed attempt can leave unburnt oil in the combustion chamber.
- Do not remove the burner cover, adjust the nozzle, electrodes or pump, or try to bleed the oil line yourself unless you are trained to.
- Do not light oil in the boiler by any other means.
- If you smell fumes, see smoke or soot around the boiler or flue, turn the boiler off at the switch, ventilate the room and do not use it until an engineer has checked it. A carbon monoxide alarm near the boiler is a sensible safeguard.
Common causes of an oil boiler not firing
| Cause | What you might notice | Can you fix it yourself? | What the engineer does |
|---|---|---|---|
| Tank empty or very low | Gauge low, recent cold spell, no delivery | Order oil | Bleeds the burner and checks the filter before restarting |
| Air in the oil line | Lockout after a delivery or after running out | No | Bleeds the fuel pump and line |
| Blocked filter or sludge | Repeated lockout, especially after the tank ran low | No | Changes the filter, checks the supply line and tank outlet |
| Water in the tank | Lockout, poor flame, often after a wet winter | No | Tests for water and advises on draining or treating the tank |
| Fire valve closed | No oil reaching the burner | No | Checks the fire valve and its sensor, resets or replaces it |
| Power or control fault | Nothing happens at all | Partly, by checking the spur and timer | Tests the supply to the burner and the controls |
| Overheat thermostat tripped | No response even though power is on | No | Finds out why it overheated before resetting |
| Worn nozzle or electrodes | Burner runs, poor or no ignition, then lockout | No | Replaces the nozzle, sets the electrode gap |
| Dirty or failed photocell | Flame lights briefly, then lockout | No | Cleans or replaces the photocell |
| Fuel pump, solenoid or control box fault | Motor runs but no oil, or random lockouts | No | Tests and replaces the faulty part |
If you have run out of oil
Running out is the single most common reason an oil boiler stops, especially in a cold snap when deliveries are busy. Filling the tank is not always enough to restart it. When the level falls to the bottom, the burner can draw air into the line, and sludge or water that settles in the bottom of a tank can be pulled towards the filter.
After a delivery, give the oil time to settle, then reset the burner once. If it will not run, the burner usually needs bleeding and the filter checking. That is an engineer’s job, because the bleed point is on the fuel pump inside the burner.
To avoid it happening again, check the level regularly from autumn onwards, and order before the tank gets low rather than when it is empty.
What an engineer will check
- Oil supply. The engineer checks oil is reaching the burner, the fire valve is open, and the filter and line are clear.
- Burner service parts. The nozzle, electrodes and photocell are inspected, cleaned or replaced. These wear with use and are normally changed at the annual service.
- Fuel pump pressure. The pump pressure is tested and set to the manufacturer’s figure.
- Controls and power. The supply to the burner, the overheat thermostat and the control box are tested.
- Combustion. Once running, a flue gas analyser confirms it is burning cleanly and safely.
Many oil boiler breakdowns trace back to a missed service, because the parts that cause lockout are the ones the service replaces.
Gas Safe does not cover oil
Gas Safe registration covers gas appliances only. Oil boilers are a separate discipline, and the usual choice is an engineer registered with OFTEC, the oil heating trade body. When you book, ask whether the engineer is trained and registered for oil work, and ask for the paperwork after any installation.
Repair or replace?
Most firing faults are repairable, and many are cured by a filter, a nozzle or a bleed. Replacement comes into the discussion when the boiler is old and inefficient, parts are hard to get, or it keeps locking out despite repairs. Our repair or replace guide sets out how we weigh it up, and our oil boiler installation page covers replacements. Installations are quoted as a fixed price after a free survey, so the price you agree is the price you pay.
What we charge to fix it
Our prices, before you ring
| Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee | £150 + VAT £180 inc VAT |
| Evenings and weekends, first hour including the call-out | £297.60 inc VAT |
| Overnight, first hour including the call-out | £330 inc VAT |
| If a new boiler is the better answer, fitted | from £2,780 inc VAT |
The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.
Frequently asked questions
How do I reset my oil boiler?
Press the reset button on the burner once, usually next to the red lockout light. If it does not fire, you can try once more, but OFTEC advises never resetting more than twice. After that, the fault needs an engineer.
Why won’t my oil boiler fire after an oil delivery?
If the tank ran empty, air will have entered the line, and the burner usually needs bleeding before it will run. Sludge disturbed by the delivery can also block the filter. Let the oil settle, reset once, then call an engineer if it still locks out.
Why does my oil boiler fire and then cut out?
A burner that lights and then shuts down usually has a flame detection or fuel delivery problem, such as a dirty photocell, a partly blocked filter or a worn nozzle. It can also be air in the line. These are engineer checks rather than homeowner fixes.
Is it dangerous if my oil boiler keeps locking out?
The lockout itself is the boiler protecting you. The danger comes from repeated resets, which can leave unburnt oil in the chamber. If you notice fumes, smoke or soot, switch it off and have it checked before you use it again.
How often should an oil boiler be serviced?
Once a year is the standard recommendation. The service replaces the parts most likely to cause a firing fault, such as the nozzle, and checks the combustion is clean and safe.
When to call an engineer
If the oil level, power and controls are all fine and the burner still locks out after a reset or two, it needs an engineer. Call us on 01462 506374, day or night, and tell us the make and model of your boiler and burner. We cover Hertfordshire, Bedfordshire and Cambridgeshire and will tell you straight away whether it is a job for us, and our boiler repair page explains how we work.
Need help today?
Call and speak to a person, any hour, any day of the year, or get a fixed price quote online.
Get a fixed price quote Call 01462 506 374Rather have an engineer look at it?
Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374