Common Oil Boiler Problems and What Causes Them

Hertfordshire, Bedfordshire & Cambridgeshire

Fully Stocked Vans12 Month Labour GuaranteeGas Safe Registered 956889

The most common oil boiler problems are a boiler that will not fire, a burner that keeps going to lockout, and faults in the fuel supply such as an empty tank, a blocked oil filter, water or sludge in the tank, or a fire valve that has closed. Many of these start outside the boiler, so a few safe checks on the tank, power and controls often find the cause, but anything inside the burner or smoke, soot and fume smells need a qualified oil engineer.

In short

  • Check the oil level first. Tank gauges can stick and show oil that is not there.
  • A burner lockout means the burner tried to light and could not detect a flame. Reset no more than twice.
  • Running the tank low can draw sludge and water into the oil line and block the filter or nozzle.
  • Smoke, soot or a smell of fumes means poor combustion. Switch the boiler off and get it checked, and make sure you have a working carbon monoxide alarm.
  • An annual service catches most burner problems before they stop the boiler.

Common oil boiler problems at a glance

ProblemLikely causesWhat you can checkWhat an engineer does
Boiler will not start at allNo power, controls not calling for heat, overheat thermostat trippedFuses, switches, programmer, thermostatTests the supply to the burner, the controls and the overheat thermostat
Burner goes to lockoutNo oil, blocked filter, worn nozzle, dirty photocell, ignition fault, air in the oil lineOil level, tank valve open, reset up to twiceChanges the filter and nozzle, cleans or replaces the photocell, checks electrodes and pump
Fires then cuts outPoor combustion, flame detection fault, blocked condensate, overheatingCondensate pipe in freezing weather, system pressureCombustion analysis, checks the photocell, flue and heat exchanger
Smoke, soot or fume smellPoor combustion, dirty burner, flue problemSwitch off and ventilateFull service, combustion setting, flue inspection
Radiators not warm enoughAir, sludge, pump, controlsBleed radiators, check the thermostatChecks circulation, cleans the system
Water or oil leakFailed seal or joint, corroded heat exchanger, oil line or tank faultLook for where it starts, turn off the tank valve for an oil leakTraces and repairs the leak

Most of the faults in the right-hand column come under our boiler repair service. Tell us it is an oil boiler, with the make and model, when you book.

Oil boiler not firing up

When an oil boiler shows no sign of life, or the burner does not start, work through these checks in order.

  1. Check the oil in the tank. Gauges can fail and show oil that is not there. If you can do it safely, look into the tank or use a clean dipstick or pole.
  2. Check the tank valve is open. There is usually a valve on the outlet of the tank. Make sure nobody has closed it.
  3. Check the power. Look at the programmer display. If it is blank, check the fused spur for the boiler and the consumer unit for a tripped switch.
  4. Check the programmer and thermostat. After a power cut, timers can lose their settings. Set the time, switch heating and hot water to on or constant, and turn the room thermostat up.
  5. Check the pressure. On a sealed system, the boiler gauge should be around 1 bar or more when cold. If it is below about 0.5 bar, top it up as your user guide describes, or see our guide on a boiler that keeps losing pressure.
  6. Check for a lockout light. Many burners have a control box with a reset button that lights up when the burner has locked out. See the next section before pressing it.

Burner lockout: what it means

An oil burner has a control box that watches for a flame, using a light-sensitive photocell. If the burner starts and no flame is seen within a set time, or the flame is lost, the control box shuts the burner down and locks out. It will stay off until someone presses the reset.

Pressing the reset once is reasonable. If the burner fires and keeps running, the lockout may have been a one-off. If it locks out again, the fault is still there. The oil industry body OFTEC advises that, for safety, a reset should never be attempted more than twice. Repeated resets will not cure the underlying fault, and a burner that is struggling to light is not one to keep forcing.

Common causes of repeated lockout:

  • No oil, or oil not reaching the burner. An empty tank, a closed valve, a tripped fire valve or a blocked filter.
  • Air in the oil line. After running out of oil, air in the line and pump can stop the burner lighting until it is bled.
  • Worn or blocked nozzle. The nozzle sprays the oil as a fine mist. Dirt or wear gives a poor spray and a poor flame.
  • Dirty or failed photocell. If the photocell cannot see the flame, the control box thinks it has gone out.
  • Ignition problems. Worn electrodes or a failed ignition transformer mean no spark.
  • Burner pump or solenoid fault. The oil pump or the valve that lets oil through may have failed.

Tank and fuel supply problems

Many oil boiler breakdowns start in the garden rather than the boiler room.

Running low. When the level gets very low, the tank outlet is more likely to draw in the water and sludge that settle at the bottom. That can block the filter and nozzle just as the tank is refilled.

Water in the tank. Condensation inside the tank, a damaged lid or a failing tank can let water in. Water in the oil causes poor combustion and lockouts, and in cold weather it can freeze in the oil line.

Blocked oil filter. There is usually a filter on the oil line near the tank or the boiler. It catches dirt and sludge, and a filter that has not been changed in years slowly starves the burner.

Fire valve. Oil systems have a fire valve that shuts off the oil if it senses a fire at the boiler. If it has been triggered, the oil will not reach the burner. This needs an engineer to check why it closed and reset or replace it.

Oil leaks. A smell of kerosene near the tank or the boiler, stained ground or dead grass around the tank all point to a leak. Turn the tank valve off if you can do it safely, keep oil away from drains, and get the tank and pipework checked quickly. If oil reaches a drain, ditch or watercourse, report it to the Environment Agency incident hotline on 0800 80 70 60.

Smoke, soot, smells and noises

A healthy oil boiler burns cleanly with no visible smoke from the flue and no smell indoors. Smoke, black soot around the flue terminal, a smell of fumes or loud rumbling on start-up all point to poor combustion. That can be caused by a worn nozzle, the wrong air setting, a blocked flue or a dirty heat exchanger.

Poor combustion is not just inefficient. Oil boilers can produce carbon monoxide, which you cannot see or smell. Since 1 October 2022, Approved Document J has required a carbon monoxide alarm to be fitted in England when a new or replacement oil boiler is installed, and every home with an oil boiler should have one. If the alarm sounds, or you notice smoke or fumes, switch the boiler off, open windows, get everyone outside if anyone feels unwell and seek medical help.

What not to do

  • Do not reset the burner more than twice. OFTEC advises against it for safety.
  • Do not remove the burner cover, or touch the nozzle, pump, photocell, electrodes or control box.
  • Do not try to bleed the oil pump or reset a fire valve yourself.
  • Do not keep running a boiler that is smoking, sooting or smelling of fumes.
  • Do not let the tank run very low, and do not ignore an oil smell near the tank.

Oil boilers are not gas appliances, so the Gas Safe Register does not cover them. Work on the burner should be done by an engineer trained in oil firing, and OFTEC runs the main registration scheme for oil technicians in the UK.

Condensing oil boilers and frozen condensate

Most oil boilers fitted in recent years are condensing boilers, which produce acidic water that drains away through a condensate pipe. In freezing weather that pipe can block with ice, and the boiler shuts down. If the pipe outside is frozen, pour warm, not boiling, water over it. Our guide to a frozen condensate pipe explains how to find and thaw it.

Heating not warm enough

If the burner runs but the house stays cool, the problem is often in the heating system rather than the boiler. Air, sludge, a sticking pump or a zone valve fault can all stop heat reaching the radiators. Bleed any radiators that are cool at the top, and see our guide to a radiator not heating up for the other causes.

What an engineer will check

An oil engineer works from the fuel supply through to the burner and flue: checking the tank, the oil line and the filter, testing oil pump pressure, replacing the nozzle and cleaning or testing the photocell and electrodes, and checking the fire valve. They then clean the combustion chamber and heat exchanger if needed, and set the burner up with a flue gas analyser so it burns cleanly. Manufacturers such as Grant say their oil boilers should be serviced at least every twelve months, and a regular boiler service is the best way to avoid the nozzle, filter and combustion faults above.

Repair or replace?

Most oil boiler faults are repairable: a filter, a nozzle, a photocell, an electrode or a pump. Replacement is worth thinking about when the boiler is old and inefficient, needs a major part such as a heat exchanger, or keeps breaking down despite servicing. Our guide on how long a boiler lasts explains the signs, and our oil boiler installation page covers how a replacement is planned.

What we charge to fix it

Our prices, before you ring

Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee£150 + VAT
£180 inc VAT
Evenings and weekends, first hour including the call-out£297.60
inc VAT
Overnight, first hour including the call-out£330
inc VAT
If a new boiler is the better answer, fittedfrom £2,780
inc VAT

The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.

Frequently asked questions

How do I reset an oil boiler?

Most oil burners have a reset button on the burner control box, which often lights up when the burner has locked out. Press it once and wait for the burner to try again. If it locks out again, press it once more at most, then call an engineer.

Why does my oil boiler keep locking out?

Repeated lockouts mean the burner cannot light or keep a steady flame. The usual causes are a fuel problem, such as low oil, a blocked filter or water in the tank, or a burner problem, such as a worn nozzle, a dirty photocell or an ignition fault.

Why won’t my oil boiler start after the tank was refilled?

If the tank ran dry, air can get into the oil line and pump, and sludge from the bottom of the tank can block the filter. The burner may need the line bleeding and the filter changing before it will run. That is a job for an oil engineer.

How often should an oil boiler be serviced?

At least once a year. Grant, for example, says its oil boilers should be serviced at least every twelve months to keep the guarantee valid. Servicing replaces wearing parts such as the nozzle and keeps the combustion set correctly.

When to call an engineer

If the burner locks out again after two resets, the fuel supply looks fine, or you notice smoke, soot or fumes, it is time for an engineer. We cover Hertfordshire, Bedfordshire and Cambridgeshire from our Stevenage base. Book through our boiler repair page or call 01462 506374, answered 24 hours a day, 7 days a week.

Need help today?

Call and speak to a person, any hour, any day of the year, or get a fixed price quote online.

Get a fixed price quote Call 01462 506 374
Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.