Potterton Boiler Faults: Common Problems and Fault Codes Explained
Hertfordshire, Bedfordshire & Cambridgeshire
The most common Potterton boiler faults are low water pressure (E119 on older models, E118 on the newer Assure range), a failure to light because of a gas supply or ignition problem (E133), and circulation or overheat faults (E125 and E110). Low pressure and a frozen condensate pipe are things you can usually sort out yourself, but most other Potterton fault codes point to a sensor, pump, fan or ignition part that needs a Gas Safe registered engineer.
In short
- Potterton boilers are made by Baxi and use the same style of E codes as many Baxi boilers.
- Older models such as the Promax HE Plus and Gold Combi HE show three-digit codes in two halves, so E133 appears as “E1” then “33”.
- Low pressure is E119 on older boilers and 118 on the Assure. Top up to the pressure in your user guide, usually between 1 and 2 bar.
- E133 means the boiler could not light or lost its flame. Check your gas supply and, in freezing weather, the condensate pipe.
- Reset once or twice at most. If the same code comes back, book an engineer.
How Potterton fault codes work
Potterton is part of the Baxi group, and its boilers share parts and fault code systems with Baxi models of the same era. When a Potterton boiler detects a problem it shuts down and shows a code starting with E, or just the number on some newer displays.
On older boilers with a two-digit display, such as the Promax Combi HE Plus A range, the user guide explains that codes are two or three digits long and that a three-digit code is shown in two parts. E133 is displayed as “E1” alternating with “33”. Watch the display for a few seconds and write down the whole code before you do anything else, because that is what an engineer, and our boiler repair team, will ask for first.
Potterton fault codes and what they mean
The codes below come from Potterton’s own user guides. The first table covers older models such as the Promax HE Plus and Gold Combi HE; the second covers the newer Assure Combi. Wording and codes differ between ranges, so always check your own user guide.
Older Potterton boilers (Promax HE Plus, Gold Combi HE and similar)
| Code | Meaning in the Potterton user guide | Can you do anything yourself? |
|---|---|---|
| E20 | Central heating temperature sensor (NTC) fault | No |
| E28 | Flue temperature sensor (NTC) fault | No |
| E50 | Hot water temperature sensor (NTC) fault | No |
| E110 | Safety thermostat operated, the boiler has overheated | Check pressure, bleed radiators, reset once |
| E119 | Water pressure switch not operated, pressure below 0.5 bar | Usually yes, repressurise |
| E125 | Pump or circulation fault | Check pressure and bleed radiators |
| E130 | Flue temperature sensor operated, the flue has overheated | Reset once only |
| E133 | Interruption of gas supply or flame failure | Check the gas supply and condensate pipe, reset once |
| E160 | Fan or fan wiring fault | No |
Potterton Assure Combi
| Code | Meaning in the Potterton user guide | Can you do anything yourself? |
|---|---|---|
| 09 | Gas valve connection cable | No |
| 15 | Gas valve fault | No |
| 20 | Central heating temperature sensor fault | No |
| 28 | Flue temperature sensor fault | No |
| 40 | Central heating return temperature sensor fault | No |
| 83 | Communication error | Reset once |
| 109 | Pre-circulation fault | Check pressure and bleed radiators |
| 110 | Safety thermostat operated | Check pressure, reset once |
| 118 | Primary system water pressure too low | Usually yes, repressurise |
| 125 | Circulation fault in the primary circuit | Check pressure and bleed radiators |
| 128 | Flame failure | Check the gas supply and condensate pipe |
| 130 | Flue temperature sensor operated | Reset once only |
| 133 | Interruption of gas supply or flame failure | Check the gas supply and condensate pipe, reset once |
| 135 | Interruption of gas supply (internal error) | Reset once |
| 154 | Flow and return sensor temperature test | Check pressure and bleed radiators |
| 160 | Fan or fan wiring fault | No |
| 270 | Circulation fault (dry fire) | Check pressure, then call an engineer |
| 321 | Hot water temperature sensor fault | No |
| 384 | False flame | No |
The faults we see most on Potterton boilers
Low pressure (E119 or 118)
This is the most common one. The heating system is a sealed circuit that should hold its pressure, and if it drops too low the boiler stops. The Promax guide gives a normal working pressure of between 1 and 2 bar, and the Assure guide says the same. Top up with the filling loop as your user guide shows, and close it fully afterwards. If the pressure keeps dropping, there is a leak or a faulty expansion vessel or pressure relief valve. Our Baxi and Potterton E119 guide goes through the top-up step by step.
No ignition or flame failure (E133 or 128)
The boiler tried to light and could not detect a flame, or lost it. Before calling anyone, check that your hob or other gas appliances work and that a prepayment meter has credit. In freezing weather, a frozen condensate pipe is a very common cause, because the boiler cannot drain and shuts down. If the gas supply is fine, the cause is usually the ignition or flame sensing electrode, the gas valve or the flue. See our Baxi E133 guide for the full list of causes.
Circulation and overheat faults (E125, E110 and related codes)
These appear when water is not moving through the boiler properly, so it heats up too fast. Air in the system, low pressure, sludge, a sticking pump or a closed valve are the usual causes. Bleed any radiators that are cold at the top and check the pressure, then reset once. If it returns, the pump or the system needs attention. Our guides to Baxi E125 and Baxi E110 apply to Potterton boilers of the same family.
Fan faults (E160)
A fan fault means the boiler cannot prove the fan is running at the right speed, so it will not light. This is an engineer job, and our Baxi E160 guide explains what gets tested.
Sensor faults (E20, E28, E50 and 321)
Temperature sensors are small parts, but the boiler cannot run safely without them. A sensor fault usually means the sensor or its wiring needs testing and replacing.
Check these first
- Write down the full code. On older displays, watch for both halves.
- Check the pressure gauge. With the system cold it should be within the range in your user guide, usually 1 to 2 bar. If it is low, top it up.
- Check the gas supply. Try the hob or another gas appliance, and check a prepayment meter.
- Check the condensate pipe in cold weather. If the plastic pipe outside is frozen, pour warm, not boiling, water over it. Our guide to a frozen condensate pipe shows how.
- Bleed radiators that are cold at the top, then recheck the pressure.
- Reset once. On the Promax and Gold, turn the selector switch to the reset position and hold for about 5 seconds. On the Assure, press the reset button for about 1 second; the guide warns that holding it for more than 2 seconds will not reset the boiler. If the code comes back, stop.
What not to do
- Do not keep resetting. Repeated resets will not fix the cause and can lock the boiler out.
- Do not remove the casing or touch the fan, gas valve, pump, circuit board, heat exchanger or flue. Under the Gas Safety (Installation and Use) Regulations 1998 only a Gas Safe registered engineer may work on a gas appliance.
- Do not overfill when topping up, or the pressure relief valve may open.
- If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows, do not use electrical switches, and turn the gas off at the meter if it is safe to do so.
What an engineer will check
A good engineer uses the full code and Potterton’s fault-finding chart for your exact model. Depending on the code, that means checking the system pressure and expansion vessel, the pump and circulation, the temperature sensors and safety thermostat, the gas pressure at the boiler, the ignition and flame sensing electrodes, the fan, the flue and the condensate trap. After any gas-side repair, combustion is checked with a flue gas analyser.
Repair or replace?
Most Potterton faults are routine repairs: a sensor, a pump, an electrode, a fan or a pressure top-up. Replacement makes more sense when the boiler is well over ten years old, needs a major part such as the heat exchanger or circuit board, or keeps breaking down. We repair and service Potterton boilers along with all the other major brands.
What we charge to fix it
Our prices, before you ring
| Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee | £150 + VAT £180 inc VAT |
| Evenings and weekends, first hour including the call-out | £297.60 inc VAT |
| Overnight, first hour including the call-out | £330 inc VAT |
| If a new boiler is the better answer, fitted | from £2,780 inc VAT |
The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.
Frequently asked questions
Where is the reset button on a Potterton boiler?
It depends on the model. On older boilers such as the Promax HE Plus and Gold Combi HE, there is no separate button: you turn the selector switch to the reset position and hold it. On the Assure, there is a reset button on the control panel. Your user guide shows exactly where it is.
What is the most common Potterton boiler fault?
Low water pressure, shown as E119 on older models and 118 on the Assure. It is usually fixed by topping up the pressure with the filling loop, but if it keeps happening there is a leak or a failing part to find.
Why does my Potterton boiler keep showing E133?
E133 means the boiler could not light or lost its flame. If other gas appliances work and the condensate pipe is not frozen, the cause is usually inside the boiler, such as the ignition electrode, the gas valve or the flue, and needs an engineer.
Are Potterton and Baxi fault codes the same?
Many are, because both brands are made by the same group and use similar parts. E119, E133, E125 and E160 mean much the same on Potterton and older Baxi boilers. Newer ranges use different numbers, so always check the user guide for your model.
Is it safe to leave a Potterton boiler showing a fault code?
Yes. When a fault code is showing, the boiler has shut down and is not burning gas. It is safe to leave it off until an engineer arrives. If you smell gas at any point, call 0800 111 999.
Potterton boiler repairs in Hertfordshire, Bedfordshire and Cambridgeshire
If your Potterton boiler is showing a code that keeps coming back, our own Gas Safe registered engineers (registration 956889) can find the cause and fix it. We cover Hertfordshire, Bedfordshire and Cambridgeshire from our Stevenage base. Book a boiler repair or call 01462 506374, answered 24 hours a day, 7 days a week.
Need help today?
Call and speak to a person, any hour, any day of the year, or get a fixed price quote online.
Get a fixed price quote Call 01462 506 374Rather have an engineer look at it?
Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town: