Central Heating Winter Checklist: How to Get Your Heating Ready
Hertfordshire, Bedfordshire & Cambridgeshire
To get your central heating ready for winter, run it for an hour in early autumn, check the boiler pressure, bleed any radiators that are cold at the top, set your thermostat and timer, protect the condensate pipe and book a boiler service before the cold weather arrives. Doing this in September or October finds faults while engineers are less busy, rather than on the first freezing night.
In short
- Turn the heating on for a test run before you need it, and note anything unusual.
- Most sealed systems sit around 1 to 1.5 bar when cold, but check the figure in your boiler’s user guide.
- Bleed radiators that are cold at the top, then recheck the pressure.
- Set the thermostat to the lowest comfortable temperature, which the Energy Saving Trust puts at 18C to 21C for most people.
- An annual boiler service before winter is the best way to avoid a breakdown when you need heat most.
Why prepare your heating before winter
A boiler that has sat idle all summer can develop small faults that only show up when it has to work hard. Pumps and valves can stick, air collects in radiators, and pressure drops slowly. Finding this in early autumn means a planned fix. Finding it in December means a cold house while you wait. An annual boiler service before the heating season is the single most useful thing you can book.
Your central heating winter checklist
1. Do a test run
Pick a mild day in September or October. Turn the thermostat up and let the heating run for at least an hour.
- Does the boiler fire up straight away?
- Do all the radiators get warm?
- Does the hot water still work while the heating is on?
- Is there any banging, gurgling or whistling?
- Does a fault code appear on the display?
Write down anything odd. It helps the engineer and saves time. If the boiler will not start at all, check the gas supply to other appliances, the thermostat and the fused spur, then call an engineer.
2. Check the boiler pressure
On a combi or system boiler, look at the pressure gauge with the heating off and cold. Most manufacturers give a cold pressure of around 1 to 1.5 bar, but your user guide has the right figure for your boiler.
- Too low: you can usually top it up with the filling loop if the user guide explains how. Open the valves slowly, watch the gauge, and close them fully when it reaches the right level.
- Keeps dropping: there is a leak on the system or a fault with the expansion vessel or pressure relief valve. See why a boiler keeps losing pressure.
- Too high when hot: it can indicate an expansion vessel problem, which needs an engineer.
3. Bleed the radiators
With the heating on, feel each radiator. A radiator that is cold at the top and warm at the bottom has air in it. Turn the heating off, let it cool, then bleed it with a radiator key until water appears. Our step-by-step guide on how to bleed a radiator shows you how. Bleeding lets water out, so check the boiler pressure afterwards and top up if needed.
A radiator that is cold at the bottom or in the middle is different. That usually means sludge, and bleeding will not fix it. Our article on a radiator not heating up explains the causes.
4. Free the valves
Thermostatic radiator valves (TRVs) can stick after a summer on the same setting. Turn each one fully open and fully closed a few times. If a radiator stays cold with the valve fully open, the pin inside the head may be stuck, which a plumber can free or replace.
5. Set your controls
- Thermostat: the Energy Saving Trust suggests the lowest comfortable temperature, which for most people is between 18C and 21C.
- Timer or programmer: match it to when you are actually at home and awake. Heating the house while everyone is out wastes gas.
- TRVs: turn them down in spare rooms and hallways, but avoid leaving rooms completely unheated for long periods, which can lead to condensation and mould.
- Frost setting: if your boiler or thermostat has frost protection, make sure it is switched on.
If your controls are old or confusing, a smart thermostat can make it easier to heat only the rooms and times you need.
6. Protect the condensate pipe
Modern condensing boilers drain acidic water through a plastic pipe. Where that pipe runs outside, it can freeze in a cold snap and stop the boiler. Check it is insulated, as short as possible and not sagging. If it has frozen before, ask the engineer about rerouting or upsizing it. Our guide to a frozen condensate pipe explains how to thaw it safely.
7. Protect pipes and tanks
- Lag exposed pipes in lofts, garages and under floors.
- Insulate the loft tank, but not directly underneath it.
- Know where your stop tap is and check it turns.
- If you are away in winter, leave the heating on low rather than off.
8. Check your carbon monoxide alarm
Test your CO alarm and check its expiry date. You should have one in any room with a gas boiler, gas fire or other fuel-burning appliance. An alarm is a backup, not a replacement for a service.
9. Book the boiler service
A service checks that the boiler is burning gas safely and efficiently, cleans parts that clog over time and spots wear before it becomes a breakdown. Most manufacturers require an annual service to keep the guarantee valid. Book it for early autumn, before demand peaks.
Stay safe
- Only a Gas Safe registered engineer may work on your boiler, gas pipes or flue. Never remove the boiler casing.
- If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows, do not use switches, and turn off the gas at the meter if it is safe to do so.
- A yellow or orange flame, sooty marks around the boiler or a CO alarm going off mean you should stop using the appliance and get it checked.
- Headaches, dizziness or nausea that ease when you leave the house can be carbon monoxide poisoning. Get outside and get medical advice.
Problems a winter check often finds
| What you notice | Likely cause | Can you fix it yourself? | What an engineer does |
|---|---|---|---|
| Radiators cold at the top | Air in the system | Yes, bleed them | Checks why air keeps getting in |
| Radiators cold at the bottom | Sludge | No | Cleans the system, may recommend a power flush |
| Pressure keeps dropping | Leak, expansion vessel or relief valve | Top up only | Finds and repairs the fault |
| Boiler locks out on cold nights | Frozen condensate pipe | Thaw with warm water | Insulates or reroutes the pipe |
| Banging or kettling noises | Scale or sludge in the heat exchanger, pump issue | No | Diagnoses and cleans or repairs |
| Some rooms never get warm | Poor balancing, stuck valves, undersized radiators | Free TRVs | Balances the system, checks radiator sizes |
If several radiators have cold patches and the water is dark when you bleed them, a power flush may be worth considering before winter.
When to call an engineer rather than wait
- The boiler shows a fault code that comes back after a reset.
- The pressure falls below the minimum more than once.
- You can see water leaking from the boiler or pipework.
- There is any sign of a gas or carbon monoxide problem.
- The boiler has not been serviced in over a year.
What we charge to fix it
Our prices, before you ring
| Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee | £150 + VAT £180 inc VAT |
| Evenings and weekends, first hour including the call-out | £297.60 inc VAT |
| Overnight, first hour including the call-out | £330 inc VAT |
| If a new boiler is the better answer, fitted | from £2,780 inc VAT |
The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.
Frequently asked questions
When should I turn my central heating on for winter?
There is no fixed date. Most people start using it when evenings regularly feel cold, often in October. Do a test run in September or early October so any fault is found before you rely on it.
What pressure should my boiler be at in winter?
Pressure does not change with the season. Most sealed systems sit around 1 to 1.5 bar when cold and rise a little when hot, but your user guide gives the right figure for your boiler. If it keeps dropping, get it checked.
Should I bleed my radiators every year?
Only if they need it. Feel each radiator when the heating is on, and bleed any that are cold at the top. If you find yourself bleeding the same radiators often, air is getting into the system and an engineer should find out why.
Is it cheaper to leave the heating on low all day?
For most homes, heating only when you need it, using a timer and thermostat, uses less energy than leaving it on all day. The exception is protecting against frost when you are away, when leaving it on low is sensible.
Do I need a boiler service every year?
Manufacturers recommend an annual service, and most require it to keep the guarantee valid. It is also the best way to make sure the boiler is running safely before winter.
Boiler servicing in Hertfordshire, Bedfordshire and Cambridgeshire
If your heating needs a pre-winter check, our Gas Safe engineers service all the major boiler brands. See our boiler servicing page or call 01462 506374. The phone is answered 24 hours a day, 7 days a week, with 24/7 emergency cover if your heating fails.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374