Radiator Not Heating Up

Hertfordshire, Bedfordshire & Cambridgeshire

Fully Stocked Vans2 Year Labour GuaranteeGas Safe Registered 956889

A single cold radiator when the rest of the house is warm is almost always one of four things, and where the radiator is cold tells you which.

Thermal image of a radiator before a Vantage power flush, reading 24.8C with heat reaching only the bottom of the panel.
Before: heat only at the bottom, 24.8°C
Thermal image of a radiator at 54.2C after a Vantage power flush, with dust sheets protecting the carpet below.
After: 54.2°C across the whole panel
New copper radiator tails fitted beneath lifted floorboards during a Vantage heating installation.
New copper tails on the radiator

Cold at the top, warm at the bottom

Air. Hot water rises, air collects at the top and stops the radiator filling. Bleed it and check the boiler pressure afterwards, because bleeding drops it.

Vantage engineer working on radiator pipework
A radiator cold at the bottom is a different problem from one cold at the top.

Cold at the bottom, warm at the top

Sludge. Corrosion settles in the bottom of the radiator and blocks the flow. Bleeding will not shift it and it gets worse over time.

This normally needs a power flush, which cleans the whole system rather than one radiator.

Cold all over, while others are fine

Usually a valve. Check the thermostatic valve is open, and check the lockshield valve at the other end has not been closed. On a system that has been balanced badly, one radiator can be starved while the rest run hot.

A stuck TRV pin is common and free to fix. Take the head off the thermostatic valve and you will see a small pin. If it is stuck down, the valve is shut. Free it gently with pliers, moving it up and down a few times. Radiators that have been off all summer do this every autumn.

Cold downstairs but fine upstairs, or the reverse

That is a system-wide issue rather than one radiator: often the pump, a zone valve that has failed, or a system that has never been balanced. It needs an engineer.

All the radiators are cold

Then it is not the radiators. Check the boiler is firing, the pressure is 1 to 1.5 bar, and the thermostat and programmer are calling for heat. See boiler not firing up.

How Vantage can help

We cover Hertfordshire, Bedfordshire and Cambridgeshire and we carry out power flushing and system balancing as well as repairs.

Call us on 01462 506374. See also power flushing and boiler repair.

Frequently asked questions

Why is my radiator cold at the bottom?

Sludge. Bleeding will not fix it and it needs flushing.

Should I bleed a radiator that is cold at the bottom?

It will not help. Cold at the top is air, cold at the bottom is sludge.

What is a lockshield valve?

The valve at the opposite end to the thermostatic one, used to balance flow between radiators.

Why do radiators stop working after summer?

Thermostatic valve pins seize when they have been closed for months. Freeing the pin usually fixes it.

Want it sorted properly?

If the fault keeps returning after a reset, it is telling you something is degrading rather than broken. Call 01462 506374 and we will diagnose it properly rather than swapping parts and hoping. Gas Safe registered 956889, 2 years on our own labour.

Need help today?

Call and speak to a person, any hour, any day of the year, or get a fixed price quote online.

Get a fixed price quote Call 01462 506 374
Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.