Vaillant Boiler Fault Codes: Full List and What to Do
Hertfordshire, Bedfordshire & Cambridgeshire
A Vaillant fault code is an F followed by a number, such as F.22 or F.28, and it tells you why the boiler has stopped or locked out. A few codes have simple causes you can check yourself, mainly low water pressure (F.22), failed ignition (F.28 and F.29) and air or low water in the system (F.75), but most point to a sensor, the fan, the gas valve or the electronics and need a Gas Safe registered engineer.
In short
- F codes are faults. S codes are status messages that show what the boiler is doing, not faults.
- The codes you can safely check: F.22 (low pressure), F.28 and F.29 (ignition), F.75 (pressure not detected when the pump starts).
- Vaillant’s manuals allow up to three resets. If the code keeps returning, stop and call an engineer.
- Codes such as F.00, F.20, F.27, F.32, F.61 and F.62 point to parts inside the boiler.
- The same code can mean slightly different things on older and newer models, so check your model’s user guide.

New boiler?
Get an instant estimate for a new boiler
Answer a few questions about your home online and see your estimate straight away, fitted by our own engineers.
How Vaillant boiler codes work
Most Vaillant boilers you will see in UK homes, including the ecoTEC pro and ecoTEC plus, use two kinds of code:
- F codes (faults). F.xx on the display means the boiler has found a fault and has either stopped or locked out. The boiler usually shows a warning symbol with it.
- S codes (status). S.xx tells you what the boiler is doing. On the ecoTEC pro, for example, S.04 means the burner is on for heating and S.14 means it is making hot water. S.46 shows that the boiler has detected a fault and is running in a restricted comfort protection mode.
Some models also show a spanner or maintenance symbol when a service is due. The boiler keeps working while that is displayed.
The codes in this guide come from Vaillant’s installation and maintenance manuals for the ecoTEC pro and ecoTEC plus. Older Vaillant boilers and some newer models use different codes or wording, so if a code on your boiler does not match, check your own user guide. Our boiler repair engineers work on Vaillant boilers of every age.
Check these first
Whatever the code, these checks are safe for any homeowner:
- Check the pressure gauge. Vaillant’s ecoTEC pro user guide says the pressure should be between 1 and 2 bar when the system is cold, and the boiler switches off below 0.5 bar. If it is low, top it up with the filling loop as your user guide shows.
- Check the gas. Do your other gas appliances work? If you have a prepayment meter, does it have credit?
- Check the condensate pipe in cold weather. A frozen condensate pipe stops the boiler working. Thaw it with warm, not boiling, water.
- Check the power. Make sure the fused spur next to the boiler is on and the fuse has not blown.
- Press reset. Vaillant’s manual says to press the reset button no more than three times. If the code returns, stop.
What not to do
- Do not keep pressing reset beyond the three attempts the manual allows. It will not fix the cause and can hide the real problem.
- Never remove the boiler casing or touch anything inside it. Under the Gas Safety (Installation and Use) Regulations 1998, only a Gas Safe registered engineer may work on a gas boiler.
- Do not pour boiling water on a frozen condensate pipe.
- If you smell gas, call the National Gas Emergency Service on 0800 111 999, open the windows, do not use electrical switches and turn off the gas at the meter if it is safe to do so.
The codes you are most likely to see
F.22: low water pressure
The boiler has shut down because the pressure in the heating system has dropped too low. Top it up with the filling loop and reset. If it keeps dropping, there is a leak or an expansion vessel problem. See our Vaillant F22 fault code guide.
F.28: ignition failed
The boiler tried to light and did not detect a flame. Common causes are a gas supply problem, a frozen or blocked condensate pipe, air in the gas after meter work, or a worn ignition electrode. Our Vaillant F28 fault code guide covers the checks.
F.29: flame lost during operation
The flame went out while the boiler was running and it could not relight. A temporary break in the gas supply, a blocked condensate pipe or flue gases being drawn back in can cause it. See the Vaillant F29 fault code guide.
F.75: no pressure change when the pump starts
The boiler did not detect the pressure rise it expects when the pump starts. Air in the system, low water, a faulty pump or a faulty pressure sensor are the usual causes. Read the Vaillant F75 fault code guide.
F.32: fan fault
The boiler is not getting the correct signal from the fan. Vaillant’s manual lists a loose plug on the fan or the board, a break in the wiring, a blocked fan, a faulty fan sensor or the electronics as causes, so this one needs an engineer. See the Vaillant F32 fault code guide.
Full list of Vaillant ecoTEC fault codes
| Code | What it means | Can you do anything? |
|---|---|---|
| F.00 | Flow temperature sensor interruption | No, engineer |
| F.01 | Return temperature sensor interruption | No, engineer |
| F.02, F.03 | Cylinder or store sensor interruption (models with an actoSTOR hot water store) | No, engineer |
| F.10 | Flow temperature sensor short circuit | No, engineer |
| F.11 | Return temperature sensor short circuit | No, engineer |
| F.13 | Cylinder or warm start sensor short circuit | No, engineer |
| F.20 | Safety switch-off, temperature limiter (overheat) | Check pressure and bleed radiators once, then engineer |
| F.22 | Low water pressure | Yes, top up the pressure |
| F.23 | Temperature difference between flow and return too great | Check pressure and bleed radiators, then engineer |
| F.24 | Temperature rising too fast | Check pressure and bleed radiators, then engineer |
| F.25 | Flue gas temperature too high | No, engineer |
| F.26 | Gas valve not working | No, engineer |
| F.27 | Flame detected when the gas valve is closed | No, engineer |
| F.28 | Ignition unsuccessful at start-up | Check gas and condensate pipe, reset |
| F.29 | Flame lost and re-ignition unsuccessful | Check gas and condensate pipe, reset |
| F.32 | Fan fault | No, engineer |
| F.42 | Output coding resistor fault | No, engineer |
| F.49 | eBUS fault (controls communication) | No, engineer |
| F.52, F.53, F.56 | Mass flow sensor, combustion regulation or combustion component fault | No, engineer |
| F.54 | Gas supply fault | Check other gas appliances and the meter |
| F.57 | Comfort protection mode ended, regulation fault | No, engineer |
| F.61, F.62 | Gas valve control or switch-off fault | No, engineer |
| F.63, F.64, F.65, F.67 | Electronics faults (memory, sensor, temperature, flame signal) | No, engineer |
| F.68 | Unstable flame signal | No, engineer |
| F.70 | Invalid device specific number (after parts replaced) | No, engineer |
| F.71, F.72 | Flow or return temperature sensor readings wrong | No, engineer |
| F.73, F.74 | Water pressure sensor signal out of range | No, engineer |
| F.75 | No pressure change detected when the pump starts | Check pressure, bleed radiators, reset |
| F.77 | Flue non-return flap or condensate pump fault | No, engineer |
| F.83 | No temperature change at the flow and return sensors on start-up | Check pressure, then engineer |
| F.84, F.85 | Flow and return sensors implausible or fitted incorrectly | No, engineer |
| F.92, F.93 | Gas coding or combustion quality fault | No, engineer |
| Communication fault | Display and main board not communicating | No, engineer |
Not every code appears on every model. The F.02, F.03 and F.13 codes, for instance, relate to boilers with a built-in or connected hot water store.
Common causes, grouped
| Group | Codes | What you might notice | What the engineer does |
|---|---|---|---|
| Water pressure and circulation | F.22, F.23, F.24, F.75, F.83 | Low pressure, cold radiators, noisy boiler | Tops up, bleeds, checks pump, pressure sensor and expansion vessel |
| Ignition and gas | F.28, F.29, F.54, F.68 | No heating or hot water, boiler tries to light | Checks gas pressure, electrode, condensate route and flue |
| Temperature sensors | F.00, F.01, F.10, F.11, F.71, F.72 | Boiler locks out straight away | Tests sensors and wiring, replaces faulty sensor |
| Fan and flue | F.25, F.32, F.77 | Boiler will not start its sequence | Tests fan and wiring, checks flue and condensate |
| Gas valve and electronics | F.26, F.27, F.61 to F.67 | Lockout, sometimes blank or frozen display | Tests gas valve and board, replaces as needed |
Our engineers work from fully stocked vans, and if a part is needed that we do not carry, we quote it before ordering and fitting it.
What an engineer will check
A Gas Safe engineer starts with the code and the boiler’s fault history, which many Vaillant boilers store. They check the pressure, gas supply and condensate route, then test the part the code points to: sensor resistance, fan signal, electrode condition, gas pressure at the valve, and the wiring between them and the board. On a lockout that keeps returning, they also check the flue and combustion readings with an analyser.
Repair or replace?
Most Vaillant faults are routine repairs: a sensor, an electrode, a pressure sensor, a fan or a pump. On a boiler that has otherwise been reliable, repairing is usually the right answer. Replacement is worth considering when the boiler is well into its working life and needs a major part such as the main board or heat exchanger, or when several different faults have appeared in a short time. We will always tell you honestly which makes more sense.
What it costs with Vantage
In normal working hours there is no call-out fee. Gas faults start with a fixed-price Gas Safe diagnostic visit, and if we can fix it on the same visit, part of that diagnostic charge comes off the repair. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive.
Frequently asked questions
How do I reset a Vaillant boiler?
Press the reset button on the control panel, usually marked with a flame and a line through it, or the reset symbol on newer models. Vaillant’s manual says to try no more than three times. If the fault keeps coming back, call a Gas Safe engineer.
What is the most common Vaillant fault code?
F.22 (low water pressure) and F.28 (ignition failure) are two of the most common. Both have causes a homeowner can check, such as topping up the pressure or thawing a frozen condensate pipe.
What is the difference between an F code and an S code?
An F code is a fault that has stopped or limited the boiler. An S code is a status message showing what the boiler is doing, such as heating or making hot water. S codes are normal.
Why does my Vaillant boiler keep showing F.22?
The pressure keeps dropping, which means water is leaving the system. The usual causes are a leak on a radiator, valve or pipe, a pressure relief valve letting by, or an expansion vessel that has lost its charge. An engineer can find it.
Where can I find the fault codes for my model?
Your Vaillant user guide lists the codes a homeowner may see. The full list is in the installation and maintenance manual, which your engineer will have. You can also browse our boiler advice guides for individual codes.
Vaillant boiler repairs in Hertfordshire, Bedfordshire and Cambridgeshire
If your Vaillant is showing a fault code that will not clear, our own Gas Safe registered engineers (registration 956889) can diagnose and repair it. We are a Vaillant myREWARDS installer, rated 4.9 on Google, and our phone is answered 24 hours a day, 7 days a week, with 24/7 emergency cover. See our boiler repair page or call 01462 506374.
What our customers say
Rather have an engineer look at it?
Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374