Skip to main content

Vantage Plumbing and Heating

Vaillant Boiler Fault Codes: Full List and What to Do

Hertfordshire, Bedfordshire & Cambridgeshire

Fully Stocked Vans12 Month Labour GuaranteeGas Safe Registered 956889

A Vaillant fault code is an F followed by a number, such as F.22 or F.28, and it tells you why the boiler has stopped or locked out. A few codes have simple causes you can check yourself, mainly low water pressure (F.22), failed ignition (F.28 and F.29) and air or low water in the system (F.75), but most point to a sensor, the fan, the gas valve or the electronics and need a Gas Safe registered engineer.

In short

  • F codes are faults. S codes are status messages that show what the boiler is doing, not faults.
  • The codes you can safely check: F.22 (low pressure), F.28 and F.29 (ignition), F.75 (pressure not detected when the pump starts).
  • Vaillant’s manuals allow up to three resets. If the code keeps returning, stop and call an engineer.
  • Codes such as F.00, F.20, F.27, F.32, F.61 and F.62 point to parts inside the boiler.
  • The same code can mean slightly different things on older and newer models, so check your model’s user guide.
Vaillant boiler installed by Vantage with neatly run copper pipework
A Vaillant boiler we installed, with the copper pipework run neatly below it.

New boiler?

Get an instant estimate for a new boiler

Answer a few questions about your home online and see your estimate straight away, fitted by our own engineers.

Instant boiler estimateOr call 01462 506 374

How Vaillant boiler codes work

Most Vaillant boilers you will see in UK homes, including the ecoTEC pro and ecoTEC plus, use two kinds of code:

  • F codes (faults). F.xx on the display means the boiler has found a fault and has either stopped or locked out. The boiler usually shows a warning symbol with it.
  • S codes (status). S.xx tells you what the boiler is doing. On the ecoTEC pro, for example, S.04 means the burner is on for heating and S.14 means it is making hot water. S.46 shows that the boiler has detected a fault and is running in a restricted comfort protection mode.

Some models also show a spanner or maintenance symbol when a service is due. The boiler keeps working while that is displayed.

The codes in this guide come from Vaillant’s installation and maintenance manuals for the ecoTEC pro and ecoTEC plus. Older Vaillant boilers and some newer models use different codes or wording, so if a code on your boiler does not match, check your own user guide. Our boiler repair engineers work on Vaillant boilers of every age.

Check these first

Whatever the code, these checks are safe for any homeowner:

  1. Check the pressure gauge. Vaillant’s ecoTEC pro user guide says the pressure should be between 1 and 2 bar when the system is cold, and the boiler switches off below 0.5 bar. If it is low, top it up with the filling loop as your user guide shows.
  2. Check the gas. Do your other gas appliances work? If you have a prepayment meter, does it have credit?
  3. Check the condensate pipe in cold weather. A frozen condensate pipe stops the boiler working. Thaw it with warm, not boiling, water.
  4. Check the power. Make sure the fused spur next to the boiler is on and the fuse has not blown.
  5. Press reset. Vaillant’s manual says to press the reset button no more than three times. If the code returns, stop.

What not to do

  • Do not keep pressing reset beyond the three attempts the manual allows. It will not fix the cause and can hide the real problem.
  • Never remove the boiler casing or touch anything inside it. Under the Gas Safety (Installation and Use) Regulations 1998, only a Gas Safe registered engineer may work on a gas boiler.
  • Do not pour boiling water on a frozen condensate pipe.
  • If you smell gas, call the National Gas Emergency Service on 0800 111 999, open the windows, do not use electrical switches and turn off the gas at the meter if it is safe to do so.

The codes you are most likely to see

F.22: low water pressure

The boiler has shut down because the pressure in the heating system has dropped too low. Top it up with the filling loop and reset. If it keeps dropping, there is a leak or an expansion vessel problem. See our Vaillant F22 fault code guide.

F.28: ignition failed

The boiler tried to light and did not detect a flame. Common causes are a gas supply problem, a frozen or blocked condensate pipe, air in the gas after meter work, or a worn ignition electrode. Our Vaillant F28 fault code guide covers the checks.

F.29: flame lost during operation

The flame went out while the boiler was running and it could not relight. A temporary break in the gas supply, a blocked condensate pipe or flue gases being drawn back in can cause it. See the Vaillant F29 fault code guide.

F.75: no pressure change when the pump starts

The boiler did not detect the pressure rise it expects when the pump starts. Air in the system, low water, a faulty pump or a faulty pressure sensor are the usual causes. Read the Vaillant F75 fault code guide.

F.32: fan fault

The boiler is not getting the correct signal from the fan. Vaillant’s manual lists a loose plug on the fan or the board, a break in the wiring, a blocked fan, a faulty fan sensor or the electronics as causes, so this one needs an engineer. See the Vaillant F32 fault code guide.

Full list of Vaillant ecoTEC fault codes

CodeWhat it meansCan you do anything?
F.00Flow temperature sensor interruptionNo, engineer
F.01Return temperature sensor interruptionNo, engineer
F.02, F.03Cylinder or store sensor interruption (models with an actoSTOR hot water store)No, engineer
F.10Flow temperature sensor short circuitNo, engineer
F.11Return temperature sensor short circuitNo, engineer
F.13Cylinder or warm start sensor short circuitNo, engineer
F.20Safety switch-off, temperature limiter (overheat)Check pressure and bleed radiators once, then engineer
F.22Low water pressureYes, top up the pressure
F.23Temperature difference between flow and return too greatCheck pressure and bleed radiators, then engineer
F.24Temperature rising too fastCheck pressure and bleed radiators, then engineer
F.25Flue gas temperature too highNo, engineer
F.26Gas valve not workingNo, engineer
F.27Flame detected when the gas valve is closedNo, engineer
F.28Ignition unsuccessful at start-upCheck gas and condensate pipe, reset
F.29Flame lost and re-ignition unsuccessfulCheck gas and condensate pipe, reset
F.32Fan faultNo, engineer
F.42Output coding resistor faultNo, engineer
F.49eBUS fault (controls communication)No, engineer
F.52, F.53, F.56Mass flow sensor, combustion regulation or combustion component faultNo, engineer
F.54Gas supply faultCheck other gas appliances and the meter
F.57Comfort protection mode ended, regulation faultNo, engineer
F.61, F.62Gas valve control or switch-off faultNo, engineer
F.63, F.64, F.65, F.67Electronics faults (memory, sensor, temperature, flame signal)No, engineer
F.68Unstable flame signalNo, engineer
F.70Invalid device specific number (after parts replaced)No, engineer
F.71, F.72Flow or return temperature sensor readings wrongNo, engineer
F.73, F.74Water pressure sensor signal out of rangeNo, engineer
F.75No pressure change detected when the pump startsCheck pressure, bleed radiators, reset
F.77Flue non-return flap or condensate pump faultNo, engineer
F.83No temperature change at the flow and return sensors on start-upCheck pressure, then engineer
F.84, F.85Flow and return sensors implausible or fitted incorrectlyNo, engineer
F.92, F.93Gas coding or combustion quality faultNo, engineer
Communication faultDisplay and main board not communicatingNo, engineer

Not every code appears on every model. The F.02, F.03 and F.13 codes, for instance, relate to boilers with a built-in or connected hot water store.

Common causes, grouped

GroupCodesWhat you might noticeWhat the engineer does
Water pressure and circulationF.22, F.23, F.24, F.75, F.83Low pressure, cold radiators, noisy boilerTops up, bleeds, checks pump, pressure sensor and expansion vessel
Ignition and gasF.28, F.29, F.54, F.68No heating or hot water, boiler tries to lightChecks gas pressure, electrode, condensate route and flue
Temperature sensorsF.00, F.01, F.10, F.11, F.71, F.72Boiler locks out straight awayTests sensors and wiring, replaces faulty sensor
Fan and flueF.25, F.32, F.77Boiler will not start its sequenceTests fan and wiring, checks flue and condensate
Gas valve and electronicsF.26, F.27, F.61 to F.67Lockout, sometimes blank or frozen displayTests gas valve and board, replaces as needed

Our engineers work from fully stocked vans, and if a part is needed that we do not carry, we quote it before ordering and fitting it.

What an engineer will check

A Gas Safe engineer starts with the code and the boiler’s fault history, which many Vaillant boilers store. They check the pressure, gas supply and condensate route, then test the part the code points to: sensor resistance, fan signal, electrode condition, gas pressure at the valve, and the wiring between them and the board. On a lockout that keeps returning, they also check the flue and combustion readings with an analyser.

Repair or replace?

Most Vaillant faults are routine repairs: a sensor, an electrode, a pressure sensor, a fan or a pump. On a boiler that has otherwise been reliable, repairing is usually the right answer. Replacement is worth considering when the boiler is well into its working life and needs a major part such as the main board or heat exchanger, or when several different faults have appeared in a short time. We will always tell you honestly which makes more sense.

What it costs with Vantage

In normal working hours there is no call-out fee. Gas faults start with a fixed-price Gas Safe diagnostic visit, and if we can fix it on the same visit, part of that diagnostic charge comes off the repair. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive.

Frequently asked questions

How do I reset a Vaillant boiler?

Press the reset button on the control panel, usually marked with a flame and a line through it, or the reset symbol on newer models. Vaillant’s manual says to try no more than three times. If the fault keeps coming back, call a Gas Safe engineer.

What is the most common Vaillant fault code?

F.22 (low water pressure) and F.28 (ignition failure) are two of the most common. Both have causes a homeowner can check, such as topping up the pressure or thawing a frozen condensate pipe.

What is the difference between an F code and an S code?

An F code is a fault that has stopped or limited the boiler. An S code is a status message showing what the boiler is doing, such as heating or making hot water. S codes are normal.

Why does my Vaillant boiler keep showing F.22?

The pressure keeps dropping, which means water is leaving the system. The usual causes are a leak on a radiator, valve or pipe, a pressure relief valve letting by, or an expansion vessel that has lost its charge. An engineer can find it.

Where can I find the fault codes for my model?

Your Vaillant user guide lists the codes a homeowner may see. The full list is in the installation and maintenance manual, which your engineer will have. You can also browse our boiler advice guides for individual codes.

Vaillant boiler repairs in Hertfordshire, Bedfordshire and Cambridgeshire

If your Vaillant is showing a fault code that will not clear, our own Gas Safe registered engineers (registration 956889) can diagnose and repair it. We are a Vaillant myREWARDS installer, rated 4.9 on Google, and our phone is answered 24 hours a day, 7 days a week, with 24/7 emergency cover. See our boiler repair page or call 01462 506374.

What our customers say

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.