Egg Timer Symbol on a Vaillant Boiler: What It Means
Hertfordshire, Bedfordshire & Cambridgeshire
The egg timer (hourglass) symbol on a Vaillant boiler display means the burner anti-cycling time is active: the boiler has just reached temperature on the heating and is deliberately waiting before it lights again, so it does not keep switching on and off. It is normal, it is not a fault, and the heating will start again on its own once the timer runs out, which is 20 minutes at most on the factory setting.
In short
- Vaillant’s operating instructions list this symbol as “burner anti-cycling time is active”, to avoid frequent switching on and off and extend the boiler’s life.
- It only applies to central heating. On a combi, hot water should still work while the egg timer is showing.
- The maximum wait is set by the installer. The factory setting is 20 minutes, and the actual wait is often shorter.
- Seeing it now and then is normal. Seeing it all the time while the house stays cold points to short cycling, which has a cause worth finding.
- If the display shows an F code instead, that is a fault, not anti-cycling.

What the egg timer means
A boiler is sized to heat the whole house on a cold day. Much of the time, especially in spring and autumn or once rooms have warmed up, the radiators need far less heat than the boiler can give. Without any control, the boiler would light, reach its target temperature in a minute or two, switch off, cool slightly and light again, over and over. That is called short cycling, and it wastes gas and wears out ignition parts, fans and the gas valve.
To stop that, Vaillant boilers have a burner anti-cycling time. When the boiler switches off because the heating water has reached temperature, it will not relight for a set period, even if the water cools a little. While that timer is running, the display shows the egg timer.
Vaillant’s operating instructions for the ecoTEC plus and ecoTEC pro ranges list the symbol as “burner anti-cycling time is active”, with the explanation that it is there to avoid frequent switching on and off, which increases the product’s working life. The same state appears as a status code: S.08 on the ecoTEC pro, and S.008 on the current ecoTEC plus, described as heating mode active with the unit in burner anti-cycling time.
How long does the egg timer last?
The installer sets the maximum anti-cycling time in the boiler’s installer menu (diagnostic code d.02). Vaillant’s installation instructions give the factory setting as 20 minutes, adjustable from 2 to 60 minutes. The actual wait each time depends on the flow temperature the boiler is aiming for, so it is often shorter than the maximum. On some models the display or the live monitor shows the minutes remaining.
So if you have just seen the egg timer appear, the simplest thing to do is wait. Within 20 minutes on a boiler at the factory setting, the burner should light again if the heating is still calling for heat.
Does the egg timer stop hot water?
No. Anti-cycling only applies to heating mode. On a Vaillant combi, turning on a hot tap while the egg timer is showing should still light the burner for hot water. If you have no hot water at all while the egg timer is showing, something else is going on and it is worth a check. On a system or heat only boiler with a cylinder, heating the cylinder is a separate demand, and it is controlled by your programmer and cylinder thermostat.
When the egg timer is normal, and when it is not
| What you see | What it probably means | What to do |
|---|---|---|
| Egg timer for a few minutes after the heating has been on a while | Normal anti-cycling, rooms nearly up to temperature | Nothing |
| Egg timer on a mild day with most radiators turned down | Normal, the heat demand is low | Nothing |
| Egg timer almost every time you look, house not warming | Short cycling: the boiler reaches temperature too quickly | Check pressure, bleed radiators, open radiator valves, then get it checked |
| Egg timer with low pressure on the display | Poor circulation or a pressure problem | Top up to the pressure in your user guide |
| Egg timer and an F code, or an F code alone | A fault, not anti-cycling | Look up the code and follow the advice for it |
| Egg timer and no hot water on a combi | Something other than anti-cycling | Book an engineer |
If the egg timer is showing most of the time and the house never warms up, book a boiler repair so an engineer can work out why the boiler is reaching temperature so quickly.
Why a Vaillant boiler short cycles
If the egg timer seems to be on constantly, the boiler is heating the water in its heat exchanger faster than the radiators can take the heat away. Common reasons are:
- Low system pressure or air in the system. Poor circulation means hot water does not move away from the boiler, so it reaches temperature quickly. Check the pressure, and see our guide to a boiler that keeps losing pressure if it keeps dropping.
- Sludge in the system. Black iron oxide sludge restricts flow through radiators and the boiler. Cold patches at the bottom of radiators are a clue, and our guide on a radiator not heating up explains the causes.
- Most radiators turned down or off. With only one or two radiators open, there is little for the boiler to heat.
- A pump or valve problem. A sticking pump, a failed diverter valve or a zone valve that is not opening properly all reduce flow.
- A boiler that is too big for the house. An oversized boiler reaches temperature very quickly, particularly in mild weather.
- Controls set up poorly. A thermostat in the wrong place or a flow temperature that does not suit the system can make the boiler switch on and off more than it should.
Check these first
- Wait 20 minutes. If the heating is still calling and the egg timer clears and the burner lights, it was normal anti-cycling.
- Check the pressure. Vaillant’s ecoTEC pro instructions give a cold filling pressure of between 1 and 2 bar, and the ecoTEC plus instructions recommend at least 1 bar. If it is low, top it up with the filling loop as your user guide shows, and see our Vaillant F22 guide for more on low pressure.
- Bleed the radiators that are cold at the top. Our guide on how to bleed a radiator shows how. Check the pressure again afterwards.
- Open the radiator valves in the main rooms, so the boiler has somewhere to send its heat.
- Check the room thermostat is set above the room temperature and is calling for heat.
- Look for an F code. If one is showing, that is a fault and needs its own fix.
What not to do
- Do not try to change the anti-cycling time yourself. It is in the installer menu, and wrong settings can cause other problems.
- Do not keep pressing reset. The egg timer is not a fault, so a reset is not the fix, and repeated resets for real faults can lock the boiler out.
- Do not remove the casing or touch anything inside the boiler. Under the Gas Safety (Installation and Use) Regulations 1998 only a Gas Safe registered engineer may work on a gas appliance.
- If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows, do not use electrical switches, and turn the gas off at the meter if it is safe to do so.
What an engineer will check
An engineer will read the status and fault history in the boiler, check the anti-cycling and flow temperature settings against the system, and look at why the boiler is reaching temperature so quickly. That usually means checking the system pressure and expansion vessel, the pump, the diverter or zone valves, flow through the radiators and signs of sludge, and whether the boiler’s output suits the house. Sometimes the fix is a settings change; sometimes it is a system clean, a new pump or better controls. A regular boiler service is a good time to have the settings checked.
Related codes
- Vaillant F22, low water pressure: see the Vaillant F22 fault code guide.
- Vaillant F75, pressure change not detected when the pump starts: see the Vaillant F75 fault code guide.
What we charge to fix it
Our prices, before you ring
| Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee | £150 + VAT £180 inc VAT |
| Evenings and weekends, first hour including the call-out | £297.60 inc VAT |
| Overnight, first hour including the call-out | £330 inc VAT |
| If a new boiler is the better answer, fitted | from £2,780 inc VAT |
The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.
Frequently asked questions
Why does my Vaillant boiler show an egg timer?
It is showing that the burner anti-cycling time is active. The boiler has just reached its heating temperature and is waiting before it lights again, to avoid switching on and off too often. It is normal and clears on its own.
How long does the Vaillant egg timer last?
Up to 20 minutes on the factory setting, although the installer can set a different maximum of between 2 and 60 minutes. The actual wait depends on the flow temperature and is often shorter.
Can I get rid of the egg timer on my Vaillant boiler?
Not safely by yourself. The anti-cycling time is an installer setting. If it is causing a real problem, such as a house that never warms up, an engineer should find out why the boiler is short cycling rather than just turning the timer down.
Will I still get hot water when the egg timer is showing?
On a Vaillant combi, yes. Anti-cycling only applies to heating, so the boiler should still fire for hot water. If it does not, there is another fault to look at.
Is the egg timer a fault code?
No. Vaillant fault codes start with F, such as F.22 or F.28. The egg timer is a normal operating symbol, and the matching status code is S.08 or S.008 depending on the model.
When to call an engineer
If the egg timer is on most of the time, the house does not warm up, or you have no hot water while it is showing, it is worth getting the boiler looked at. We repair and service Vaillant boilers across Hertfordshire, Bedfordshire and Cambridgeshire from our Stevenage base, and we are Gas Safe registered (956889) and a Vaillant myREWARDS installer. Book a boiler repair or call 01462 506374, answered 24 hours a day, 7 days a week.
Need help today?
Call and speak to a person, any hour, any day of the year, or get a fixed price quote online.
Get a fixed price quote Call 01462 506 374Rather have an engineer look at it?
Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374