Skip to main content

Vantage Plumbing and Heating

Vaillant F00 Fault Code: What It Means and What to Do

Hertfordshire, Bedfordshire & Cambridgeshire

Fully Stocked Vans12 Month Labour GuaranteeGas Safe Registered 956889

Vaillant F00 (shown as F.00) means the boiler has lost the signal from its flow temperature sensor, the sensor that measures the water leaving the heat exchanger. Without that reading the boiler cannot control its temperature safely, so it stops, and while there is little a homeowner can fix, the repair is usually straightforward: a loose plug, a damaged wire or a faulty sensor, all of which need a Gas Safe registered engineer.

In short

  • F.00 is listed in Vaillant’s manuals as “flow temperature sensor interruption”, an open circuit between the sensor and the board.
  • The boiler stops heating and, on a combi, stops making hot water.
  • The causes are a loose or disconnected plug, a broken wire, a faulty sensor or, less often, the circuit board.
  • You can note the code, check the power and try the reset up to three times. After that, call an engineer.
  • A sensor or wiring repair is one of the simpler Vaillant repairs and is rarely a reason to replace the boiler.
Vaillant boiler installed by Vantage with neatly run copper pipework
A Vaillant boiler we installed, with the copper pipework run neatly below it.

New boiler?

Get an instant estimate for a new boiler

Answer a few questions about your home online and see your estimate straight away, fitted by our own engineers.

Instant boiler estimateOr call 01462 506 374

What F00 means

Your Vaillant boiler has two main temperature sensors on the heating side: one on the flow, measuring the hot water leaving the boiler, and one on the return, measuring the water coming back from the radiators. They are thermistors, often called NTC sensors, whose electrical resistance changes with temperature. The circuit board reads that resistance and uses it to control the burner, protect against overheating and work out how the system is running.

Vaillant’s installation manuals for the ecoTEC pro and ecoTEC plus list F.00 as “flow temperature sensor interruption”. In plain terms, the board is no longer receiving a signal from the flow sensor. That is an open circuit: something between the sensor and the board has broken or come apart, or the sensor itself has failed.

Because the boiler cannot tell how hot the water in the heat exchanger is, it shuts down rather than risk overheating. Our boiler repair engineers see this code on Vaillant boilers of all ages.

F.00 is the open circuit version of a sensor fault. If the sensor or its wiring has shorted instead, you are more likely to see F.10. A fault on the return sensor shows as F.01 or F.11.

Check these first

There is not much a homeowner can safely do for F.00, but these checks are worthwhile:

  1. Write down the code and any other code that appears. It helps the engineer.
  2. Check the power. Make sure the fused spur next to the boiler is on. If the boiler has been switched off and on at the spur recently, note that too.
  3. Reset the boiler. Press the reset button. Vaillant’s manual says to try no more than three times. A sensor plug that is only just making contact can occasionally clear, but if F.00 comes back, the fault is real.
  4. Think about recent work. If the boiler was serviced or repaired shortly before F.00 appeared, a plug may have been disturbed. Tell the engineer who did the work, as it may be a quick fix for them.
  5. Look for water. If you can see water dripping from the boiler or pipework below it, switch the boiler off at the spur and call an engineer. Water and electrical connections do not mix.
  6. Check the pressure gauge. It will not cause F.00, but if it is low the engineer will want to know. See our guide to a boiler that keeps losing pressure.

What not to do

  • Never remove the boiler casing to check the sensor or its plug. Under the Gas Safety (Installation and Use) Regulations 1998, only a Gas Safe registered engineer may work on a gas boiler, and there are live electrical parts inside.
  • Do not keep resetting beyond the three attempts the manual allows.
  • Do not try to bypass or bridge a sensor. It is there to stop the boiler overheating.
  • If you smell gas, call the National Gas Emergency Service on 0800 111 999, open the windows, do not use electrical switches and turn off the gas at the meter if it is safe to do so.

Common causes of F00

CauseWhat you might noticeCan you fix it yourself?What the engineer does
Sensor plug loose or not pushed homeF.00 after a service or repair, or appearing on and offNoReseats and checks the plug
Multi-plug on the circuit board looseF.00, sometimes with other sensor codesNoReseats the plug on the board and checks the pins
Break in the wiring harnessF.00 that will not clearNoTests the wiring for continuity and repairs or replaces the harness
Faulty flow temperature sensorF.00 that will not clear, wiring tests fineNoTests the sensor’s resistance and replaces it
Corrosion or moisture at the connectorF.00 after a leak or in a damp locationNoCleans or replaces the connector and fixes the source of the water
Circuit board faultF.00 with a sensor and wiring that test fineNoDiagnoses and replaces the board if needed

The first four causes are the ones Vaillant lists in its manuals. Most F.00 repairs end up being a plug, a wire or the sensor itself.

What an engineer will check

A Gas Safe engineer will usually:

  1. Confirm the code and check the boiler’s fault history.
  2. Isolate the power and open the case.
  3. Check the plug on the flow sensor is fully seated and not corroded.
  4. Check the multi-plug where the harness joins the circuit board.
  5. Test the wiring between the sensor and the board for continuity.
  6. Measure the sensor’s resistance and compare it with Vaillant’s data for the water temperature.
  7. Replace the sensor or repair the wiring as needed, then run the boiler through heating and hot water to confirm the fault has cleared.

If the sensor and wiring are both fine, the engineer looks at the circuit board. That is less common, and a board is a bigger part, so the engineer will quote it before fitting it.

Repair or replace?

A flow sensor or a plug is one of the less costly parts on a Vaillant boiler, and the repair is quick once the cause is found. On its own, F.00 is almost never a reason to replace a boiler.

If F.00 turns out to be a failed circuit board on an older boiler that has had several other faults, it may be time to compare the repair with a new boiler. Our guide to boiler repair versus replacement explains how we help customers decide.

What it costs with Vantage

In normal working hours there is no call-out fee. Gas faults start with a fixed-price Gas Safe diagnostic visit, and if we can fix it on the same visit, part of that diagnostic charge comes off the repair. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive.

Our repairs carry a 12 month labour guarantee.

Related Vaillant codes

CodeMeaning
F.01Return temperature sensor interruption
F.10Flow temperature sensor short circuit
F.11Return temperature sensor short circuit
F.20Safety switch-off, temperature limiter
F.71Flow sensor reading a constant value
F.72Flow and return sensor fault

For more on the sensor faults, read our Vaillant F72 fault code and Vaillant F20 fault code guides.

Frequently asked questions

Can I still use my boiler with an F00 fault?

No. The boiler stops because it cannot read the flow temperature. On a combi that means no heating and no hot water until the fault is repaired. If you have an immersion heater on a hot water cylinder, you can use that for hot water in the meantime.

Is F00 dangerous?

The code itself means the boiler has protected itself by shutting down, which is what it should do. The risk comes from anyone trying to bypass the sensor or open the boiler without being Gas Safe registered.

Will resetting clear F00?

Sometimes briefly, if a plug is only just making contact. Vaillant’s manual says to try no more than three times. If F.00 keeps returning, the cause needs finding and fixing.

What is the difference between F00 and F10?

F.00 means the flow sensor circuit is open, so no signal is reaching the board. F.10 means the flow sensor or its wiring has short circuited. Both relate to the same sensor and are diagnosed in a similar way.

Does F00 mean I need a new boiler?

Almost never. It is usually a plug, a wire or the sensor, all of which are routine repairs. Only a failed circuit board on an older boiler with other problems would make replacement worth considering.

Vaillant F00 repairs in Hertfordshire, Bedfordshire and Cambridgeshire

If your Vaillant is showing F.00 and will not clear, our own Gas Safe registered engineers (registration 956889) can find the fault and fix it, with parts quoted before we fit them. We are a Vaillant myREWARDS installer, rated 4.9 on Google, and our phone is answered 24 hours a day, 7 days a week, with 24/7 emergency cover. See our boiler repair page or call 01462 506374.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.