Vaillant F03 Fault Code: Cylinder Sensor Fault Explained
Hertfordshire, Bedfordshire & Cambridgeshire
Vaillant F03 (F.03, or F.3 on older models) means the boiler has lost the signal from the temperature sensor in its hot water cylinder or built-in hot water store. It is an open circuit in the sensor or its wiring, so the boiler can no longer tell how hot the stored water is, and the repair is a sensor, plug or cable fix that needs a Gas Safe registered engineer.
In short
- Vaillant’s manuals describe F.03 as an “interruption” in the cylinder sensor: the circuit board sees an open circuit.
- On ecoTEC plus models with a built-in actoSTOR store, F.03 is the actoSTOR cylinder sensor and appears only together with F.91.
- On Vaillant’s older atmoTEC boilers, F.3 covers the cylinder temperature sensor or the warm start sensor.
- The usual causes are a failed sensor, a damaged cable or a loose plug.
- Reset once or twice at most. The sensor and wiring are inside the appliance, so leave them to an engineer.

New boiler?
Get an instant estimate for a new boiler
Answer a few questions about your home online and see your estimate straight away, fitted by our own engineers.
What F03 means on a Vaillant boiler
A boiler that heats a store of hot water needs to know how hot that water is. It uses an NTC thermistor, a sensor whose resistance drops as the temperature rises, fitted to the cylinder or store. The circuit board reads the resistance and turns it into a temperature, then decides when to heat the water and when to stop.
If that sensor circuit is broken, the board sees an open circuit and cannot read the stored water temperature at all. Rather than heat water blind, it raises F03.
The exact sensor depends on your boiler.
| Vaillant model | How Vaillant describes F.03 or F.3 | Where the sensor is |
|---|---|---|
| ecoTEC plus with actoSTOR (VUI store models) | Interruption in the actoSTOR cylinder sensor, only in combination with F.91 | In the hot water store built into the boiler |
| atmoTEC boilers | Interruption in the cylinder temperature sensor or warm start temperature sensor | On a connected cylinder, or on the hot water side of a combi with warm start |
For the ecoTEC plus, Vaillant’s installation manual lists F.03 as “Interruption cylinder sensor actoSTOR (NTC) only in combination with F.91”. The causes it gives are a defective sensor, a defective sensor cable, a bad plug connection at the sensor and a bad plug connection on the actoSTOR electronics. The actoSTOR is Vaillant’s hot water store with its own electronics, fitted inside certain ecoTEC plus models.
For the atmoTEC range, the installation manual gives F.3 as “Interruption in cylinder temperature sensor/warm start temperature sensor”. A warm start sensor is used on some combis to keep the hot water side ready so hot water arrives at the tap sooner.
F03 has a sister code. F13 is a short circuit in the same cylinder or warm start sensor, where the reading goes the other way. Vaillant’s own fault code page describes F13 as the cylinder temperature sensor having short-circuited. F03 is the open circuit. The same sensor and wiring are tested for both.
If your display shows three digits, such as F.022 rather than F.22, you have one of Vaillant’s newest controls. Give the engineer the exact code you see.
Check these first
- Write down every code you see. On an actoSTOR model, F.03 should come with F.91. Note both, plus the model name on the front of the boiler.
- Reset once. Press the reset button and let the boiler restart. If F03 returns, reset once more at most, then stop.
- Check the power. Make sure the fused spur next to the boiler is switched on.
- Check your controls. If you have a separate cylinder, make sure the hot water programmer or timer is set to on. This will not clear a sensor fault, but it rules out a simple settings problem if the code clears.
- Look for leaks. Check for water on the outside of the boiler, the store or a separate cylinder, and around its pipework. Water can reach connectors. Do not open any covers.
- Note what still works. Tell the engineer whether you have heating, hot water, both or neither.
If F03 keeps returning, book a Vaillant boiler repair and have the codes and model ready.
What not to do
- Do not open the boiler casing or the store cover. Under the Gas Safety (Installation and Use) Regulations 1998 only a Gas Safe registered engineer may work on a gas appliance.
- Do not remove or unplug a sensor from a cylinder yourself, even on a separate cylinder. You risk making the fault worse and losing the evidence the engineer needs.
- Do not keep resetting. A broken sensor circuit will not fix itself.
- If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows, do not use electrical switches and turn off the gas at the meter if it is safe.
Common causes of F03
| Cause | What you might notice | Can you fix it yourself? | What the engineer does |
|---|---|---|---|
| Failed cylinder or store sensor | Code returns straight after a reset | No | Measures the sensor’s resistance and replaces it |
| Damaged sensor cable | Code comes and goes, sometimes after work nearby | No | Tests the cable for continuity and repairs or replaces it |
| Loose plug at the sensor | Code after a service or repair | No | Reseats and inspects the connector |
| Loose plug at the actoSTOR electronics | F.03 with F.91 on a store model | No | Checks the connections on the actoSTOR board |
| Corrosion or water on a connector | Code after a leak near the boiler or cylinder | Only by stopping an external leak | Cleans or replaces the connector and fixes the leak source |
| Control electronics fault | Sensor and cable test correctly | No | Tests the board before any replacement |
Where a separate cylinder sits in an airing cupboard, its sensor cable can be crushed or pulled by items stored against it, so keep that area clear.
What an engineer will check
- Confirm the model and read the fault history. This tells the engineer which sensor F03 refers to and whether any related codes, such as F13, have appeared.
- Inspect the sensor and plugs. With the power isolated, they check the sensor is seated properly in its pocket or on its fixing, and that both ends of the cable are firmly connected and clean.
- Measure the sensor. Its resistance is checked with a meter and compared against the value expected at the current water temperature. An open circuit confirms a failed sensor or a broken cable.
- Test the cable. Each core is tested along its length for breaks, crush damage or chafing.
- Check the electronics. On an actoSTOR model the store’s electronics and its link to the main board are checked. The main circuit board is only replaced after the sensor and cable are proven good.
- Heat a full store. After the repair, the engineer lets the boiler heat the water and checks the temperature reading rises sensibly and the boiler switches off when it should.
Repair or replace?
F03 is a repair, not a reason to replace a boiler. The sensor is a small part and cable faults are quick to fix. Replacement is only worth talking about if the electronics have failed on an older boiler with other problems. Our honest repair or replace guide explains how we weigh it up.
If you have a separate hot water cylinder and are wondering about an unvented upgrade at the same time, our unvented cylinder service covers installation and repairs.
What it costs with Vantage
In normal working hours there is no call-out fee. Gas faults start with a fixed-price Gas Safe diagnostic visit, and if we can fix it on the same visit, part of that diagnostic charge comes off the repair. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive. Our work carries a 12 month labour guarantee.
Related Vaillant codes
- Vaillant F20: the overheat safety cut-out has operated.
- Vaillant F22: low water pressure in the heating system.
- Vaillant F23: the temperature difference between flow and return is too great.
Frequently asked questions
What is the difference between Vaillant F03 and F13?
Both relate to the cylinder or warm start sensor. F03 is an interruption, an open circuit where the board gets no signal. F13 is a short circuit. The engineer tests the same sensor and cable for either code.
Will I still have hot water with F03?
Do not count on it. The boiler cannot read the temperature of the stored water, so it cannot control heating it properly. Whether heating still runs depends on the model and how the fault is handled, so check and tell the engineer what you find.
Can I use an immersion heater while I wait?
If you have a separate cylinder with an immersion heater that is wired and working, you can use it for hot water in the meantime. It does not affect the boiler fault. Do not have one fitted in a hurry without a qualified electrician.
Does F03 mean the cylinder needs replacing?
No. F03 is about the sensor and its wiring, not the cylinder itself. The cylinder only needs attention if the engineer finds a separate problem, such as a leak.
When to call an engineer
If F03 returns after a reset or two, the sensor and its wiring need testing by a Gas Safe registered engineer. We repair and service Vaillant boilers across Hertfordshire, Bedfordshire and Cambridgeshire, and our phone is answered 24 hours a day, 7 days a week. Book a boiler repair or call 01462 506374.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374