Skip to main content

Vantage Plumbing and Heating

Vaillant F05 Fault Code: Flue Gas Sensor Fault Explained

Hertfordshire, Bedfordshire & Cambridgeshire

Fully Stocked Vans12 Month Labour GuaranteeGas Safe Registered 956889

Vaillant F05 (F.05, shown as F.5 in some manuals) means the boiler has lost the signal from its external flue gas sensor, the safety sensor that watches for flue gases spilling back into the room on Vaillant’s open-flued atmoTEC boilers. Treat it seriously: the boiler cannot run safely without that sensor working, so reset it once at most and have a Gas Safe registered engineer test the sensor and the flue.

In short

  • Vaillant’s installation manual for the atmoTEC range lists F.5 as “Interruption at external flue gas sensor”.
  • The causes Vaillant gives are a faulty sensor, a plug not connected or a damaged cable.
  • These sensors protect you from flue gas spillage, which can include carbon monoxide.
  • F05 is not an overheat code. On Vaillant boilers the overheat cut-out is F.20.
  • The ecoTEC plus condensing manuals we checked do not list F.05, so if you see it on an ecoTEC, confirm the exact code.
  • Do not keep resetting. Check your carbon monoxide alarm and call an engineer.
Vaillant boiler installed by Vantage with neatly run copper pipework
A Vaillant boiler we installed, with the copper pipework run neatly below it.

What F05 means on a Vaillant boiler

Most Vaillant boilers in UK homes are ecoTEC condensing boilers. They are room-sealed: they take air from outside and push flue gases out through a sealed flue using a fan. Since 2005, new gas boilers fitted in England have generally had to be high-efficiency condensing models under the Building Regulations, so room-sealed condensing boilers are now the norm.

Vaillant’s atmoTEC boilers are different. They are open-flued, which means they draw combustion air from the room they are in and send their flue gases up a flue or chimney using natural draught. If the flue is blocked or the draught fails, those gases can spill back into the room. To guard against that, atmoTEC boilers have flue gas sensors that detect spillage and shut the boiler down.

F05 is the code for a fault in one of those sensors. Vaillant’s installation and maintenance manual for the atmoTEC exclusive and atmoTEC plus lists F.5 as “Interruption at external flue gas sensor”, with the causes “Sensor defective, plug not connected, cable defective”. Interruption means an open circuit: the circuit board is getting no signal from the sensor, so it cannot tell whether flue gases are spilling or not. The safe response is to stop.

Its sister code, F.15, is a short circuit in the same external flue gas sensor. A third code, F.36, means the sensors have actually detected flue gas escaping. The manual lists causes such as a faulty or blocked flue, not enough supply air, or air being pulled back down the flue by an extractor fan or cooker hood.

You may read elsewhere that F05 is an overheat lockout. That does not match Vaillant’s manuals. On Vaillant boilers the overheat safety cut-out is F20.

Seeing F05 on an ecoTEC?

The ecoTEC plus installation manuals we checked list F.00, F.01, F.02, F.03, F.10 and onwards, with no F.05. If your ecoTEC shows something that looks like F05, write down exactly what the display says, including any dots, letters and how many digits. Small displays can be misread, and Vaillant’s newest controls show three-digit codes (for example F.022 rather than F.22). An engineer can read the fault list and confirm the real code.

Check these first

  1. Check your carbon monoxide alarm. If you have one near the boiler, make sure it is working and not sounding. If it is sounding, follow the safety steps in the box below straight away.
  2. Note the exact code and model. Write down what the display shows and the model name on the front of the boiler.
  3. Reset once. Press the reset button once. If F05 comes back, do not try again.
  4. Check the room’s air vents. An open-flued boiler needs a permanent air supply. Make sure any vents in the room or door are not blocked, covered or taped over. Never block them.
  5. Think about extractor fans. If a cooker hood or extractor fan has been fitted in the same room or next door recently, mention it. Fans can pull air back down an open flue.
  6. Look at the flue from outside. Without climbing, check whether the flue terminal or chimney looks damaged or blocked, for example by a bird’s nest. Tell the engineer what you see.

Then book a Vaillant boiler repair. F05 is not a code to live with.

Safety first

  • Carbon monoxide has no smell. Symptoms include headaches, dizziness, nausea, breathlessness, collapse and loss of consciousness. If you suspect it, turn off the boiler, open doors and windows, leave the room, call the National Gas Emergency Service on 0800 111 999 and get medical advice.
  • If you smell gas, call 0800 111 999, open windows, do not use electrical switches and turn off the gas at the meter if it is safe.
  • Do not remove the casing, unplug or bridge a sensor, or cover the flue. Under the Gas Safety (Installation and Use) Regulations 1998 only a Gas Safe registered engineer may work on a gas appliance.
  • Do not keep resetting. The boiler has stopped because it cannot confirm it is safe.

Common causes of F05

CauseWhat you might noticeCan you fix it yourself?What the engineer does
Failed external flue gas sensorCode returns straight after a resetNoTests the sensor and replaces it
Plug not connectedCode after a service, repair or flue workNoReconnects and checks the plug
Damaged sensor cableIntermittent code, or damage near the flueNoTests continuity and replaces the cable
Control board faultSensor and cable test correctlyNoTests the board input before any replacement

The first three causes are the ones Vaillant lists. Even when the fault is simply the sensor, a careful engineer checks the flue and ventilation too, because the sensor exists to protect against spillage.

What an engineer will check

  1. Confirm the model and fault history. The engineer checks that the boiler is an open-flued model and looks for related codes, especially F.15 and F.36.
  2. Inspect the sensor, plug and cable. With the power isolated, they check the external flue gas sensor is fitted correctly and the connections are sound.
  3. Test the sensor. The sensor and its cable are tested electrically. A failed sensor is replaced with the correct Vaillant part.
  4. Check the flue and ventilation. Because the sensor is a spillage safeguard, a proper engineer does not stop at the part. They check the flue route, the chimney or terminal and the room’s ventilation, and look for fans that could affect the draught.
  5. Test the safety function. Vaillant’s manual describes a check in which the flue route is deliberately blocked with a restrictor and the boiler must switch itself off within 3.5 minutes. This is an engineer’s test only.
  6. Spillage and combustion checks. The engineer confirms the flue is drawing properly and the boiler is burning correctly before leaving it running.

Repair or replace?

A failed flue gas sensor can be repaired. The harder question is the age of the boiler. Open-flued, non-condensing boilers like the atmoTEC are less efficient than a modern condensing boiler, and an older open-flued boiler with flue or ventilation problems is often a good candidate for replacement. Our repair or replace guide sets out the honest way to decide, and how long a boiler lasts gives you a sense of typical lifespans.

If you choose to replace it, a room-sealed condensing boiler takes its air from outside and does not rely on natural draught up an open flue. We are a Vaillant myREWARDS installer, and selected Vaillant boilers carry a manufacturer guarantee of up to 10 years. Every new boiler installation package includes a magnetic system filter, the first year’s service and removal of the old boiler.

What it costs with Vantage

In normal working hours there is no call-out fee. Gas faults start with a fixed-price Gas Safe diagnostic visit, and if we can fix it on the same visit, part of that diagnostic charge comes off the repair. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive.

If replacement makes more sense, installations are quoted as a fixed price after a free survey, so the price you agree is the price you pay. You can get your price online in a couple of minutes with our boiler quote tool.

Frequently asked questions

Is Vaillant F05 dangerous?

The code itself means the boiler has shut down, which is the safe outcome. The concern is why the sensor failed and whether the flue is working properly, because the sensor is there to catch flue gas spilling into the room. Have it checked promptly and make sure you have a working carbon monoxide alarm.

Is F05 an overheating fault?

No. Vaillant’s manual lists F.5 as an interruption at the external flue gas sensor. The overheat cut-out on Vaillant boilers is F.20, and it has its own causes and checks.

What is the difference between F05, F15 and F36?

F.5 is an open circuit in the external flue gas sensor, and F.15 is a short circuit in the same sensor. F.36 means the sensors have detected flue gas escaping, which points at the flue, the air supply or an extractor fan rather than at the sensor.

Can an extractor fan cause problems with my boiler?

On an open-flued boiler, yes. Vaillant’s manual lists air being pulled back through an extractor fan or cooker hood as a cause of F.36, the flue gas escape code. An engineer can carry out a spillage test with the fans running to check.

Help in Hertfordshire, Bedfordshire and Cambridgeshire

If your Vaillant is showing F05, or you are unsure which code it is, a Gas Safe registered engineer should check the sensor and the flue. We are Gas Safe registered (956889), we repair and service Vaillant boilers across Hertfordshire, Bedfordshire and Cambridgeshire, and our phone is answered 24 hours a day, 7 days a week. Book a boiler repair or call 01462 506374.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.