Viessmann Boiler Fault Codes: What They Mean and What to Do
Hertfordshire, Bedfordshire & Cambridgeshire
A Viessmann fault code is a short two-character code, such as F4 or 30, that the boiler shows when it has stopped or limited itself because of a fault, and each code points to a specific part of the boiler. Some you can safely deal with yourself, such as a frozen condensate pipe or low pressure behind F4 or F2, but most codes point to sensors, the fan, the flame or the controls and need a Gas Safe registered engineer.
In short
- On the Viessmann Vitodens 100-W, the display shows a fault symbol and the code. If the symbol flashes and “R” appears, the burner is locked out and needs a reset.
- Codes starting with F are mostly burner faults: F2 overheat, F4 no flame, F9 and FA fan faults.
- Number codes such as 30, 38, 50 and 58 are sensor faults. A 0 in the second place usually means a short circuit, an 8 usually means a broken lead.
- You can check the gas, power, pressure, condensate pipe and controls, and reset once or twice.
- Anything inside the casing is a job for a Gas Safe registered engineer.
New boiler?
Get an instant estimate for a new boiler
Answer a few questions about your home online and see your estimate straight away, fitted by our own engineers.
How Viessmann fault codes work
This guide is based on Viessmann’s installation and service instructions for the Vitodens 100-W (types B1HC and B1KC), a Viessmann boiler found in many UK homes. According to the manual, when there is a fault the display shows a fault symbol and a code. If the symbol flashes and an “R” appears, the burner has locked out, and it will not restart until it is reset.
Viessmann codes fall into a few families. Once you know the family, you know roughly where the problem is.
- Sensor codes (numbers): the boiler has lost a sensible reading from a temperature sensor. The manual pairs them: 30 is a short circuit in the boiler water temperature sensor and 38 is a lead break in the same sensor. 50 and 58 do the same for the cylinder sensor.
- Burner and safety codes (F codes): the burner could not light, lost its flame, overheated, or the fan did not behave as expected.
- Electronics codes: internal faults in the control unit or burner control unit.
- Supply codes: problems with the power or gas coming into the boiler.
Other Viessmann boilers, including newer Vitodens generations and the Vitodens 050-W, have their own manuals, and some use different displays and codes. The meanings below are for the Vitodens 100-W. If your boiler is a different model, check its own user manual or give the engineer the exact code and model.
Viessmann Vitodens 100-W fault codes
The table lists the codes in Viessmann’s manual, grouped by type, with what each one means in plain English.
| Code | What Viessmann says | What it means for you |
|---|---|---|
| F1 | Max. flue gas temperature exceeded | The flue gases got too hot. Often linked to low water or poor circulation. |
| F2 | Temperature limiter has responded | The boiler overheated and the safety limiter cut in. |
| F3 | Flame signal already present at burner start | The boiler sees a flame before it has lit. A sensing fault. |
| F4 | No flame signal | The boiler tried to light but did not detect a flame. |
| F8 | Fuel valve closes too late | A gas valve problem. Engineer only. |
| F9 | Fan speed too low during burner start | The fan is not reaching the speed it needs. |
| FA | Fan idle state not reached | The fan did not stop when it should have. |
| FC | Electrical fan control faulty | A fault in the fan control or its cable. |
| Fd, FF | Burner control unit fault | A control fault. Viessmann also mentions electrical interference near the boiler. |
| F0 | Internal fault | An internal control unit fault. |
| E3 | Fault in safety chain | A problem with the temperature limiter circuit or its leads. |
| E5 | Internal fault | Viessmann points to the ionisation electrode and its leads. |
| b7 | Burner control unit fault | The boiler runs in emergency mode. |
| 30, 38 | Boiler water temperature sensor, short circuit or lead break | The burner is blocked until the sensor is fixed. |
| 52, 5A | Flow sensor, short circuit or lead break | The burner is blocked. |
| 50, 58 | Cylinder temperature sensor, short circuit or lead break | No hot water heating from a cylinder. |
| 51, 59 | Outlet temperature sensor, short circuit or lead break | No hot water heating. |
| b0, b8 | Flue gas temperature sensor, short circuit or lead break | The burner is blocked. |
| A3 | Flue gas temperature sensor incorrectly positioned | The sensor needs refitting correctly. |
| 10, 18 | Outside temperature sensor, short circuit or lead break | The boiler keeps running, but weather compensation cannot work properly. |
| A9 | Communication error, OpenTherm device | The boiler has lost contact with an OpenTherm thermostat or control. |
| 0C | Mains voltage too low | Check the power supply to the boiler. |
| 0A | CO limiter or gas pressure switch has responded | Either carbon monoxide or low gas pressure. Treat as urgent. |
The most searched code, F4, has its own guide: Viessmann F4 explained.
Check these first
These checks are safe for a homeowner and match the basics Viessmann’s manual tells engineers to rule out.
- Write down the code and whether “R” is showing. A flashing fault symbol with “R” means a lockout.
- Check the gas. Try the hob or another gas appliance, and check a prepayment meter has credit. No gas explains F4 straight away.
- Check the power. Make sure the fused spur is on. Code 0C means low mains voltage, which can come from the supply rather than the boiler.
- Check the pressure gauge. Low system pressure can lead to overheating codes like F1 and F2. If the pressure is low and your user guide allows it, repressurise using the filling loop.
- Check the condensate pipe in cold weather. Viessmann’s manual lists the condensate drain among the checks for F4. A frozen outside pipe can stop the boiler. See our guide to a frozen condensate pipe.
- Bleed radiators if the system has air. Viessmann’s measures for F1 and F2 include venting the system. Our guide on how to bleed a radiator explains how.
- Check your thermostat. For A9, check the thermostat has power or fresh batteries.
- Reset once or twice. On the Vitodens 100-W, the manual says to press and hold R for about two seconds. If the fault is still there, the symbol stays or another code appears.
If the code returns after one or two resets, book a boiler repair rather than resetting again.
Safety and what not to do
- If the code is 0A, or a carbon monoxide alarm sounds, turn off the boiler, open windows and doors, leave the room and call the National Gas Emergency Service on 0800 111 999. Get medical advice if anyone has headaches, dizziness, nausea or breathlessness.
- If you smell gas, call 0800 111 999, open windows, do not use electrical switches and turn off the gas at the meter if it is safe.
- Do not remove the casing or touch the fan, gas valve, electrodes, sensors or control unit. Under the Gas Safety (Installation and Use) Regulations 1998 only a Gas Safe registered engineer may work on a gas appliance.
- Do not keep resetting a lockout. Each reset is another attempt at something that has already failed.
Common causes behind the codes
| Cause | Codes you might see | Can you fix it yourself? | What the engineer does |
|---|---|---|---|
| No gas or low gas pressure | F4, 0A | Only a prepay top-up or a meter valve left off | Measures gas pressure at the meter and boiler |
| Frozen or blocked condensate | F4 | Thaw with warm, not boiling, water | Clears the trap and improves the pipe run |
| Low pressure or air in the system | F1, F2 | Repressurise and bleed radiators | Finds the leak or failed expansion vessel |
| Poor circulation or a failed pump | F1, F2 | No | Checks and replaces the circulation pump |
| Electrode or lead fault | F3, F4, E5 | No | Inspects, cleans or replaces the electrode |
| Fan or fan wiring fault | F9, FA, FC | No | Tests the fan, its cable and control |
| Failed temperature sensor | 30, 38, 50, 58, 52, 5A, b0, b8 | No | Tests resistance and replaces the sensor |
| Control unit fault | F0, Fd, FF, b7 | No | Tests the controls, replaces the unit if needed |
What an engineer will check
A Gas Safe engineer starts with the code and the boiler’s history, then works from the simplest cause to the most expensive.
- Confirm the code and lockout. They note whether the fault is a lockout or a block, and check the fault history.
- Check the basics. Gas pressure, power, system pressure and the condensate route are checked first, because these are common and quick to rule out.
- Test the relevant part. For sensor codes that means measuring resistance and checking leads. For F4 it means the ignition and ionisation electrode, gas train and condensate. For fan codes it means the fan, its supply and its cable.
- Combustion check. Once the boiler runs, a flue gas analyser confirms it is burning safely and correctly.
- Quote before fitting parts. Any part is explained and priced before it goes in.
We repair and service all the major brands, including Viessmann, and our vans are fully stocked with common parts.
Repair or replace?
Most Viessmann faults are worth repairing on a boiler in good condition. Sensors and electrodes are small parts. A fan or control unit is a bigger repair but still often worthwhile. Replacement starts to make sense on an older boiler with repeated faults, or where a major part fails near the end of the boiler’s life. Our honest repair or replace guide explains how to decide.
What it costs with Vantage
In normal working hours there is no call-out fee. Gas faults start with a fixed-price Gas Safe diagnostic visit, and if we can fix it on the same visit, part of that diagnostic charge comes off the repair. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive. Our work carries a 12 month labour guarantee.
Frequently asked questions
How do I reset a Viessmann boiler?
On the Vitodens 100-W, Viessmann’s manual says to press and hold the R button for about two seconds. If the fault has cleared, the fault symbol disappears. Reset once or twice at most, and if the code returns, call an engineer.
What does the flashing R mean on a Viessmann boiler?
It means the burner has locked out after a fault, commonly after failing to light. The boiler will not restart until it is reset. If it locks out again, the cause needs finding rather than resetting.
What does Viessmann F4 mean?
F4 means the boiler tried to light but did not detect a flame. It can be caused by something as simple as no gas or a frozen condensate pipe, or by an electrode, gas valve or ignition fault that needs an engineer.
Why does my Viessmann show code 10 or 18 but still work?
Codes 10 and 18 relate to the outside temperature sensor. Viessmann’s manual says the boiler carries on running, but it can no longer adjust to the outdoor temperature properly. It is not urgent, but it should be fixed so the boiler runs efficiently.
Is a Viessmann F2 code dangerous?
F2 means the temperature limiter has cut the boiler out because it overheated, so the boiler has already made itself safe. Check the pressure and bleed any air, then reset once. If it returns, a pump, circulation or limiter fault needs an engineer.
Help in Hertfordshire, Bedfordshire and Cambridgeshire
If a Viessmann fault code keeps coming back, a Gas Safe registered engineer should find the cause. We repair and service Viessmann boilers across Hertfordshire, Bedfordshire and Cambridgeshire, and our phone is answered 24 hours a day, 7 days a week. Book a boiler repair or call 01462 506374.
What our customers say
Rather have an engineer look at it?
Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374