A Viessmann fault code is a short two-character code, such as F4 or 30, that the boiler shows when it has stopped or limited itself because of a fault, and each code points to a specific part of the boiler. Some you can safely deal with yourself, such as a frozen condensate pipe or low pressure behind F4 or F2, but most codes point to sensors, the fan, the flame or the controls and need a Gas Safe registered engineer.

In short

  • On the Viessmann Vitodens 100-W, the display shows a fault symbol and the code. If the symbol flashes and “R” appears, the burner is locked out and needs a reset.
  • Codes starting with F are mostly burner faults: F2 overheat, F4 no flame, F9 and FA fan faults.
  • Number codes such as 30, 38, 50 and 58 are sensor faults. A 0 in the second place usually means a short circuit, an 8 usually means a broken lead.
  • You can check the gas, power, pressure, condensate pipe and controls, and reset once or twice.
  • Anything inside the casing is a job for a Gas Safe registered engineer.

New boiler?

Get an instant estimate for a new boiler

Answer a few questions about your home online and see your estimate straight away, fitted by our own engineers.

Instant boiler estimateOr call 01462 506 374

How Viessmann fault codes work

This guide is based on Viessmann’s installation and service instructions for the Vitodens 100-W (types B1HC and B1KC), a Viessmann boiler found in many UK homes. According to the manual, when there is a fault the display shows a fault symbol and a code. If the symbol flashes and an “R” appears, the burner has locked out, and it will not restart until it is reset.

Viessmann codes fall into a few families. Once you know the family, you know roughly where the problem is.

  • Sensor codes (numbers): the boiler has lost a sensible reading from a temperature sensor. The manual pairs them: 30 is a short circuit in the boiler water temperature sensor and 38 is a lead break in the same sensor. 50 and 58 do the same for the cylinder sensor.
  • Burner and safety codes (F codes): the burner could not light, lost its flame, overheated, or the fan did not behave as expected.
  • Electronics codes: internal faults in the control unit or burner control unit.
  • Supply codes: problems with the power or gas coming into the boiler.

Other Viessmann boilers, including newer Vitodens generations and the Vitodens 050-W, have their own manuals, and some use different displays and codes. The meanings below are for the Vitodens 100-W. If your boiler is a different model, check its own user manual or give the engineer the exact code and model.

Viessmann Vitodens 100-W fault codes

The table lists the codes in Viessmann’s manual, grouped by type, with what each one means in plain English.

CodeWhat Viessmann saysWhat it means for you
F1Max. flue gas temperature exceededThe flue gases got too hot. Often linked to low water or poor circulation.
F2Temperature limiter has respondedThe boiler overheated and the safety limiter cut in.
F3Flame signal already present at burner startThe boiler sees a flame before it has lit. A sensing fault.
F4No flame signalThe boiler tried to light but did not detect a flame.
F8Fuel valve closes too lateA gas valve problem. Engineer only.
F9Fan speed too low during burner startThe fan is not reaching the speed it needs.
FAFan idle state not reachedThe fan did not stop when it should have.
FCElectrical fan control faultyA fault in the fan control or its cable.
Fd, FFBurner control unit faultA control fault. Viessmann also mentions electrical interference near the boiler.
F0Internal faultAn internal control unit fault.
E3Fault in safety chainA problem with the temperature limiter circuit or its leads.
E5Internal faultViessmann points to the ionisation electrode and its leads.
b7Burner control unit faultThe boiler runs in emergency mode.
30, 38Boiler water temperature sensor, short circuit or lead breakThe burner is blocked until the sensor is fixed.
52, 5AFlow sensor, short circuit or lead breakThe burner is blocked.
50, 58Cylinder temperature sensor, short circuit or lead breakNo hot water heating from a cylinder.
51, 59Outlet temperature sensor, short circuit or lead breakNo hot water heating.
b0, b8Flue gas temperature sensor, short circuit or lead breakThe burner is blocked.
A3Flue gas temperature sensor incorrectly positionedThe sensor needs refitting correctly.
10, 18Outside temperature sensor, short circuit or lead breakThe boiler keeps running, but weather compensation cannot work properly.
A9Communication error, OpenTherm deviceThe boiler has lost contact with an OpenTherm thermostat or control.
0CMains voltage too lowCheck the power supply to the boiler.
0ACO limiter or gas pressure switch has respondedEither carbon monoxide or low gas pressure. Treat as urgent.

The most searched code, F4, has its own guide: Viessmann F4 explained.

Check these first

These checks are safe for a homeowner and match the basics Viessmann’s manual tells engineers to rule out.

  1. Write down the code and whether “R” is showing. A flashing fault symbol with “R” means a lockout.
  2. Check the gas. Try the hob or another gas appliance, and check a prepayment meter has credit. No gas explains F4 straight away.
  3. Check the power. Make sure the fused spur is on. Code 0C means low mains voltage, which can come from the supply rather than the boiler.
  4. Check the pressure gauge. Low system pressure can lead to overheating codes like F1 and F2. If the pressure is low and your user guide allows it, repressurise using the filling loop.
  5. Check the condensate pipe in cold weather. Viessmann’s manual lists the condensate drain among the checks for F4. A frozen outside pipe can stop the boiler. See our guide to a frozen condensate pipe.
  6. Bleed radiators if the system has air. Viessmann’s measures for F1 and F2 include venting the system. Our guide on how to bleed a radiator explains how.
  7. Check your thermostat. For A9, check the thermostat has power or fresh batteries.
  8. Reset once or twice. On the Vitodens 100-W, the manual says to press and hold R for about two seconds. If the fault is still there, the symbol stays or another code appears.

If the code returns after one or two resets, book a boiler repair rather than resetting again.

Safety and what not to do

  • If the code is 0A, or a carbon monoxide alarm sounds, turn off the boiler, open windows and doors, leave the room and call the National Gas Emergency Service on 0800 111 999. Get medical advice if anyone has headaches, dizziness, nausea or breathlessness.
  • If you smell gas, call 0800 111 999, open windows, do not use electrical switches and turn off the gas at the meter if it is safe.
  • Do not remove the casing or touch the fan, gas valve, electrodes, sensors or control unit. Under the Gas Safety (Installation and Use) Regulations 1998 only a Gas Safe registered engineer may work on a gas appliance.
  • Do not keep resetting a lockout. Each reset is another attempt at something that has already failed.

Common causes behind the codes

CauseCodes you might seeCan you fix it yourself?What the engineer does
No gas or low gas pressureF4, 0AOnly a prepay top-up or a meter valve left offMeasures gas pressure at the meter and boiler
Frozen or blocked condensateF4Thaw with warm, not boiling, waterClears the trap and improves the pipe run
Low pressure or air in the systemF1, F2Repressurise and bleed radiatorsFinds the leak or failed expansion vessel
Poor circulation or a failed pumpF1, F2NoChecks and replaces the circulation pump
Electrode or lead faultF3, F4, E5NoInspects, cleans or replaces the electrode
Fan or fan wiring faultF9, FA, FCNoTests the fan, its cable and control
Failed temperature sensor30, 38, 50, 58, 52, 5A, b0, b8NoTests resistance and replaces the sensor
Control unit faultF0, Fd, FF, b7NoTests the controls, replaces the unit if needed

What an engineer will check

A Gas Safe engineer starts with the code and the boiler’s history, then works from the simplest cause to the most expensive.

  1. Confirm the code and lockout. They note whether the fault is a lockout or a block, and check the fault history.
  2. Check the basics. Gas pressure, power, system pressure and the condensate route are checked first, because these are common and quick to rule out.
  3. Test the relevant part. For sensor codes that means measuring resistance and checking leads. For F4 it means the ignition and ionisation electrode, gas train and condensate. For fan codes it means the fan, its supply and its cable.
  4. Combustion check. Once the boiler runs, a flue gas analyser confirms it is burning safely and correctly.
  5. Quote before fitting parts. Any part is explained and priced before it goes in.

We repair and service all the major brands, including Viessmann, and our vans are fully stocked with common parts.

Repair or replace?

Most Viessmann faults are worth repairing on a boiler in good condition. Sensors and electrodes are small parts. A fan or control unit is a bigger repair but still often worthwhile. Replacement starts to make sense on an older boiler with repeated faults, or where a major part fails near the end of the boiler’s life. Our honest repair or replace guide explains how to decide.

What it costs with Vantage

In normal working hours there is no call-out fee. Gas faults start with a fixed-price Gas Safe diagnostic visit, and if we can fix it on the same visit, part of that diagnostic charge comes off the repair. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive. Our work carries a 12 month labour guarantee.

Frequently asked questions

How do I reset a Viessmann boiler?

On the Vitodens 100-W, Viessmann’s manual says to press and hold the R button for about two seconds. If the fault has cleared, the fault symbol disappears. Reset once or twice at most, and if the code returns, call an engineer.

What does the flashing R mean on a Viessmann boiler?

It means the burner has locked out after a fault, commonly after failing to light. The boiler will not restart until it is reset. If it locks out again, the cause needs finding rather than resetting.

What does Viessmann F4 mean?

F4 means the boiler tried to light but did not detect a flame. It can be caused by something as simple as no gas or a frozen condensate pipe, or by an electrode, gas valve or ignition fault that needs an engineer.

Why does my Viessmann show code 10 or 18 but still work?

Codes 10 and 18 relate to the outside temperature sensor. Viessmann’s manual says the boiler carries on running, but it can no longer adjust to the outdoor temperature properly. It is not urgent, but it should be fixed so the boiler runs efficiently.

Is a Viessmann F2 code dangerous?

F2 means the temperature limiter has cut the boiler out because it overheated, so the boiler has already made itself safe. Check the pressure and bleed any air, then reset once. If it returns, a pump, circulation or limiter fault needs an engineer.

Help in Hertfordshire, Bedfordshire and Cambridgeshire

If a Viessmann fault code keeps coming back, a Gas Safe registered engineer should find the cause. We repair and service Viessmann boilers across Hertfordshire, Bedfordshire and Cambridgeshire, and our phone is answered 24 hours a day, 7 days a week. Book a boiler repair or call 01462 506374.

What our customers say

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.