For most combi boilers, set the heating (radiator) flow temperature to around 60 degrees, lower it to 50 to 55 in milder weather if the house stays warm, and set the hot water to around 50 degrees. If your boiler heats a hot water cylinder, do not go below about 65 degrees on the flow, because the stored water needs to reach at least 60 degrees to control legionella bacteria.

  • The boiler dial sets the flow temperature: how hot the water sent to your radiators is. The room thermostat sets how warm the house gets.
  • A lower flow temperature lets a condensing boiler condense more and use less gas.
  • Combi boilers: around 60 for heating, 50 to 55 in mild weather, and around 50 for hot water.
  • Boilers with a hot water cylinder: keep the flow at 65 or above so the cylinder reaches 60.
  • Lower gradually, check the house still gets warm, and turn it back up if it does not.
Ideal boiler installed by Vantage in a fitted cupboard, with copper pipework and a magnetic system filter
One of our boiler installations: an Ideal combi in a fitted cupboard with a magnetic system filter.

Flow temperature vs the thermostat

Your boiler has two different temperatures to think about, and people often mix them up.

  • The flow temperature is how hot the water leaving the boiler for your radiators is. It is set on the boiler, usually with a dial or button marked with a radiator symbol.
  • The room temperature is how warm you want the house. It is set on your room thermostat, typically between 18 and 21 degrees for most people, according to the Energy Saving Trust.

Turning the boiler flow temperature right up does not make the house warmer in the end. It makes the radiators hotter so the house reaches the thermostat setting a little quicker, but the boiler burns more gas to get there.

Why a lower flow temperature saves gas

Almost every boiler fitted since 2005 is a condensing boiler. It gets its high efficiency by cooling the flue gases enough for the water vapour in them to condense, which releases extra heat. For that to happen properly, the water coming back from the radiators needs to be around 55 degrees or cooler.

If the flow temperature is very high, the return water is too hot, the boiler barely condenses and a lot of that extra efficiency is lost up the flue. Vaillant advises that running the heating hotter than 60 to 70 degrees stops a boiler entering condensing mode, and the Energy Saving Trust cites research showing that turning the flow temperature down to 60 improves boiler efficiency by nearly 4%.

Recommended settings

Your systemHeating flow temperatureHot water setting
Combi boiler, older homeAround 60 in winter, 50 to 55 in spring and autumnAround 50
Combi boiler, well insulated home50 to 55 may be enough even in winterAround 50
System or regular boiler with a hot water cylinderAt least 65, so the cylinder reaches 60Cylinder thermostat at 60 or above
Boiler with weather or load compensationSet up by the installer, the boiler adjusts itselfAs above for your system

These are starting points. Every home is different, and the right setting is the lowest one that keeps your home comfortable in the weather you are having. If you are unsure, ask for your settings to be checked at your next boiler service.

Combi boilers

A combi heats radiators and hot water separately, so you can lower the heating flow without affecting your showers. Vaillant suggests 60 to 70 degrees for heating in colder months and around 50 to 55 in spring and autumn, with hot water at around 50. Some well insulated homes stay comfortable at 50 to 55 all winter.

Boilers with a hot water cylinder

If you have a system or regular boiler with a cylinder, the boiler’s flow temperature also heats your stored hot water. The Health and Safety Executive’s guidance is that hot water should be stored at 60 degrees or more to kill legionella bacteria. The Energy Saving Trust advises keeping the flow temperature at least 65 on these systems. You can still save energy by making sure the heating and hot water are only on when needed, and by checking the cylinder thermostat is set correctly rather than too high.

How to change your boiler flow temperature

Every boiler is different, so check your user manual first. In general:

  1. Take a photo of the current settings on the boiler display or dials, so you can go back if needed.
  2. Find the heating control. It is usually marked with a radiator symbol. The tap symbol is hot water.
  3. Turn the heating down in steps, for example to 60 first.
  4. Leave it for a few days and see whether rooms still reach the thermostat setting in a reasonable time.
  5. Go lower in mild weather if the house stays comfortable, to 55 or 50.
  6. Turn it back up if rooms are cold or take too long to warm, especially in a cold snap.

If your boiler has an eco mode or is linked to smart controls that adjust the flow temperature, it may already be doing some of this for you.

Before you turn it down

  • Only use the controls on the front of the boiler that the user manual describes. Never remove the casing or change installer or engineer settings.
  • If you have a hot water cylinder, do not lower the flow below about 65 degrees, and do not set the cylinder below 60.
  • Keep homes with babies, older people or anyone unwell warm enough. A lower flow is not worth a cold house.
  • If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows and do not use electrical switches.

When a lower flow temperature does not work well

Turning the flow down suits most homes, but not all of them. It may not work well if:

  • Radiators are undersized. Some rooms just cannot get warm enough at a lower temperature, especially in cold weather.
  • The pipework is microbore. Very small 8mm or 10mm pipes can struggle to deliver enough heat at lower temperatures.
  • Radiators have cold spots from air or sludge. Try bleeding your radiators first, and see our guide to a radiator not heating up.
  • The system is badly balanced, so some radiators get most of the flow and others barely warm.
  • The heating only runs for short periods. A lower flow means slightly longer heat-up times, so you may need to start the heating a little earlier.

If lowering the flow leaves rooms cold, a heating engineer can check the radiators, balance the system, clean it and look at controls such as weather compensation. An engineer can also check your settings as part of the annual service.

Hot water temperature on a combi

Around 50 degrees is enough for most households. Setting it much higher does not give you more hot water, it just means mixing in more cold at the tap, and very hot water can scald. If your showers run hot and cold, or the hot water never gets hot, the setting is unlikely to be the cause. Our guide to no hot water but heating works covers the common faults.

Controls that do it for you

  • Weather compensation uses an outdoor sensor to lower the flow temperature automatically when it is milder outside.
  • Load compensation lowers the flow temperature as the house gets close to the thermostat setting.
  • Smart controls from some manufacturers can adjust the flow temperature as well as switching the heating on and off.

Since 2018, a replacement combi boiler in England has had to be fitted with an extra energy-saving measure, and weather compensation, load compensation or a smart thermostat with automation and optimisation are among the options. If your controls are old, our smart thermostat installation service can upgrade them.

What we charge to fix it

Our prices, before you ring

Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee£150 + VAT
£180 inc VAT
Evenings and weekends, first hour including the call-out£297.60
inc VAT
Overnight, first hour including the call-out£330
inc VAT
If a new boiler is the better answer, fittedfrom £2,780
inc VAT

The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.

If you would like your settings checked, ask during your annual service. It takes little extra time when the engineer is already there.

Frequently asked questions

What is the ideal flow temperature for a boiler?

The lowest temperature that keeps your home comfortable. For most combi boilers that is around 60 in winter and 50 to 55 in milder weather. With a hot water cylinder, keep it at 65 or above.

Is 60 better than 70 on a combi boiler?

Usually, yes. At 60 the return water is cooler, so a condensing boiler condenses more and uses less gas. The Energy Saving Trust cites research showing nearly 4% better efficiency at 60. If rooms do not get warm enough at 60 in very cold weather, turn it up.

Is 50 degrees hot enough for combi hot water?

For most homes, yes. Vaillant suggests around 50 for hot water on a combi. It is hot enough for showers and washing up, and it reduces the risk of scalding.

Will lowering the flow temperature damage my boiler?

No. Condensing boilers are designed to run at lower temperatures, and that is where they are most efficient. The only caution is with a hot water cylinder, where the flow must stay high enough for the stored water to reach 60 degrees.

Why does my house take longer to warm up after lowering the flow temperature?

The radiators are running cooler, so they put out heat more slowly. Set the heating to start a little earlier, or raise the flow a few degrees in the coldest weather. If some rooms never get warm, the radiators or system may need attention.

Help in Hertfordshire, Bedfordshire and Cambridgeshire

If you are not sure what your boiler should be set to, or lowering it leaves rooms cold, our Gas Safe engineers can check and set up your system. See our boiler servicing service or call 01462 506374, answered 24 hours a day, 7 days a week.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.