Worcester Combi Boiler No Hot Water: Causes and What to Check
Hertfordshire, Bedfordshire & Cambridgeshire
When a Worcester Bosch combi gives no hot water, check first whether the heating still works: if it does, the boiler is usually fine and the fault is in the hot water side, most often the diverter valve, the hot water flow sensor or a plate heat exchanger blocked with limescale. If the heating is dead too, look at the display for a fault code, check the pressure, power and gas supply, and in freezing weather the condensate pipe, before calling a Gas Safe engineer.
In short
- Heating works but no hot water points to the diverter valve, the flow sensor or a scaled plate heat exchanger.
- No heating and no hot water points to power, gas, low pressure, a frozen condensate pipe or an ignition fault.
- Eco mode on a Worcester combi switches off preheat, so hot water takes a little longer to arrive. It is not a fault.
- An EA code means the boiler has not detected a flame. Note any code before you reset.
- Check the cold mains is on and flowing well, because a combi needs good flow to fire for hot water.
- Anything inside the casing is a job for a Gas Safe registered engineer.
How a Worcester combi makes hot water
A combi has no hot water tank. When you open a hot tap, cold mains water flows into the boiler and turns a small flow sensor, which Worcester’s service literature calls a flow turbine on its combis. The sensor tells the control board that hot water is wanted, and the board does three things: it moves the diverter valve from heating to hot water, lights the burner and sends the hot heating water through a plate heat exchanger, where it heats the mains water on its way to your tap.
If any link in that chain fails, you get no hot water, or only lukewarm water, even though the boiler may still heat the radiators perfectly well. Knowing the chain makes it much easier to tell a quick fix from a job for a boiler repair engineer.
Check these first
Work through these in order. They are all things Worcester’s own user guides ask you to check, and they are safe for a homeowner.
- Look at the display. If there is a fault code, write it down, along with any number shown with it. Our guide to Worcester Bosch fault codes explains the common ones.
- Check the power. Is the display lit? If not, check the fused spur next to the boiler and the consumer unit.
- Check the hot water setting. On Greenstar 4000 and 8000 models, press the hot water button to see the hot water temperature and make sure it has not been turned right down. On models with a programmer or smart control, check that hot water has not been switched off or scheduled off.
- Understand Eco and Preheat. Worcester explains that in Preheat mode the hot water heat exchanger is kept warm so hot water arrives faster, and Eco mode is an energy saving feature that disables preheat. In Eco, you may run the tap a little longer before it warms. On the Greenstar i, Eco is on by default.
- Check the cold water main. Run the cold kitchen tap. If the flow is weak or has stopped, the boiler may not have enough flow to trigger hot water. Check the stopcock is fully open and whether neighbours have a supply problem.
- Check the pressure gauge. Worcester’s guides ask for a cold pressure of about 1 to 1.5 bar. If it has dropped below 1 bar, top it up with the filling loop following your user guide. If it keeps dropping, see our guide to a boiler that keeps losing pressure.
- Check the gas. Do other gas appliances work? If you have a prepayment meter, is there credit?
- In freezing weather, check the condensate pipe. A frozen condensate pipe shuts the boiler down. Worcester suggests thawing it from the outside with a hot water bottle, a microwaveable heat pack or a cloth soaked in hot (not boiling) water. Our frozen condensate pipe guide shows how.
- Reset once or twice. On Greenstar 4000 and 8000 models, Worcester says to press the up and down keys until Reset is displayed. On the Greenstar i, press the reset button briefly. If the fault comes straight back, stop resetting.
- Try more than one tap. If only one tap or shower has no hot water, the problem is that tap, mixer or shower valve, not the boiler.
What not to do
- Do not remove the boiler casing. Under the Gas Safety (Installation and Use) Regulations 1998 only a Gas Safe registered engineer may work on a gas appliance, including the diverter valve, flow sensor and heat exchanger.
- Do not keep resetting a boiler that locks out again straight away. Repeated lockouts point to a real fault.
- Do not pour boiling water on a frozen condensate pipe. It can crack the plastic.
- If you smell gas, call the National Gas Emergency Service on 0800 111 999, open windows, do not use electrical switches and turn the gas off at the meter if it is safe.
Heating works but no hot water
This is the most common version of the problem on any combi, and it narrows things down a lot. Our general guide to no hot water but the heating works covers other boiler types; on a Worcester combi the usual causes are:
- Diverter valve. If it sticks in the heating position, water never gets sent to the plate heat exchanger. A giveaway is radiators getting warm when you run a hot tap in summer.
- Flow sensor or turbine. If it is blocked with debris or scale, or has failed, the boiler never knows you opened a tap, so the burner does not light for hot water.
- Plate heat exchanger. In hard water areas like Hertfordshire, limescale builds up inside it. The early signs are hot water that goes hot and cold or is only lukewarm, and a noisy boiler on hot water. In time the flow through it drops so far that you get almost none.
- Hot water temperature sensor. Worcester’s service literature describes an A7 code as a faulty hot water sensor, and notes the boiler carries on producing hot water, but the temperature control becomes less accurate.
No heating and no hot water
If the boiler will not do anything, the fault is common to both. The usual causes are loss of power, no gas, low system pressure, a frozen or blocked condensate pipe, or an ignition problem. Worcester uses the EA code when the boiler has not detected a flame during operation; our Worcester EA fault code guide explains what an engineer checks.
Common causes at a glance
| Cause | What you might notice | Can you fix it yourself? | What the engineer does |
|---|---|---|---|
| Hot water turned down or off | Water only warm, or no demand shown | Yes | Nothing needed |
| Eco mode | Hot water takes longer to arrive | Yes, switch to Preheat if you prefer | Nothing needed |
| Low mains flow | Weak cold flow too, hot water cuts out when other taps run | Partly, check the stopcock | Checks incoming flow and pipe sizes |
| Low system pressure | Gauge below 1 bar, possibly a code | Yes, if the user guide allows topping up | Finds the leak or failed part |
| Frozen condensate pipe | Cold weather, boiler locks out | Yes, thaw with warm water | Insulates or reroutes the pipe |
| Diverter valve fault | Heating works, radiators warm when taps run | No | Repairs or replaces the diverter valve |
| Flow sensor or turbine fault | Burner does not light when a tap opens | No | Cleans or replaces the sensor |
| Scaled plate heat exchanger | Hot water fluctuates, lukewarm, noisy | No | Replaces the heat exchanger and advises on scale protection |
| Ignition or gas fault | EA code, no heating or hot water | No | Checks gas supply, ignition and flame sensing |
What an engineer will check
A Gas Safe engineer reads the fault history, checks that the boiler is seeing hot water demand when a tap is opened and measures the flow rate the boiler detects. They then test the diverter valve, the flow sensor and the hot water sensor, check the gas pressure and combustion, and look at how well the plate heat exchanger is transferring heat. If limescale is the root cause, they will talk to you about scale protection or a water softener so the new part lasts.
If your boiler is still within its manufacturer guarantee, contact Worcester Bosch first, because repairs by someone else can affect the guarantee. We repair and service all the major brands, including Worcester Bosch, once it is outside the guarantee or if you would rather use a local engineer.
Repair or replace?
On a boiler under about ten years old, a diverter valve, flow sensor or plate heat exchanger is usually well worth repairing. On an older boiler with other problems, or one that needs several major parts at once, it can make more sense to replace it. We will always tell you which parts are needed before we fit them, so you can decide.
What we charge to fix it
Our prices, before you ring
| Weekday repair visit, Monday to Friday 8am to 5pm, no call-out fee | £150 + VAT £180 inc VAT |
| Evenings and weekends, first hour including the call-out | £297.60 inc VAT |
| Overnight, first hour including the call-out | £330 inc VAT |
| If a new boiler is the better answer, fitted | from £2,780 inc VAT |
The weekday visit is a fixed price. A Gas Safe engineer comes out, finds the fault and does any small fix that needs no parts, with up to an hour on site. If the repair needs parts or more time, you get a fixed price before anything else is done. We cover Hertfordshire, Bedfordshire, Cambridgeshire and North London. Book a boiler repair, see every rate, or get a new boiler price online.
Frequently asked questions
Why is my Worcester combi heating working but no hot water?
The heating side is fine, so the fault is in the parts that only work for hot water: usually the diverter valve, the flow sensor or turbine, or a plate heat exchanger blocked with scale. All of these are inside the casing and need a Gas Safe engineer.
How do I reset my Worcester combi boiler?
It depends on the model. On Greenstar 4000 and 8000 boilers, press the up and down keys until Reset is shown; on the Greenstar i, press the reset button briefly. Reset only a couple of times, and call an engineer if the fault returns.
What does Eco mode do on a Worcester boiler?
Eco switches off the preheat function, which keeps the hot water heat exchanger warm when you are not using it. It saves energy, but hot water takes a little longer to reach the tap. Switch to Preheat if you would rather have faster hot water.
Why does my Worcester combi hot water go hot and cold?
Fluctuating hot water is often limescale in the plate heat exchanger, low mains flow or a sticking diverter valve. Running more than one hot tap at once can also exceed what a combi can heat, so try a single tap first.
Can low water pressure stop hot water on a combi?
Yes, in two ways. Low pressure in the heating system can stop the boiler running at all, and low flow from the cold mains can mean the boiler does not detect enough demand to fire for hot water.
Worcester combi repairs in Hertfordshire, Bedfordshire and Cambridgeshire
If your Worcester combi has stopped giving hot water and the simple checks have not helped, our Gas Safe engineers can find the faulty part and fix it. See our boiler repair page or call 01462 506374. The phone is answered 24 hours a day, 7 days a week.
Need help today?
Call and speak to a person, any hour, any day of the year, or get a fixed price quote online.
Get a fixed price quote Call 01462 506 374Rather have an engineer look at it?
Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374