Skip to main content

Vantage Plumbing and Heating

Boiler Electrodes Explained: Ignition and Flame Sensing Faults

Hertfordshire, Bedfordshire & Cambridgeshire

Fully Stocked Vans12 Month Labour GuaranteeGas Safe Registered 956889

Boiler electrodes are the small metal probes inside the combustion chamber that light the gas (the ignition electrode) and confirm there is a flame (the flame sensing electrode). When one wears or gets dirty, the boiler usually tries to light, fails and locks out with an ignition or flame loss fault code, and because the electrodes sit inside the sealed part of the boiler, checking or replacing them is a job for a Gas Safe registered engineer.

In short

  • Most gas boilers have an ignition electrode that makes the spark and a flame sensing electrode that proves the flame is lit. Some combine both in one.
  • Electrodes wear with every start, and can crack, bend or build up deposits.
  • The usual sign is a boiler that clicks, fails to light and locks out, or lights then cuts out.
  • The same symptoms can come from a gas supply problem or a frozen condensate pipe, which you can check yourself.
  • Electrodes are inside the sealed case. Only a Gas Safe engineer should inspect, clean or replace them.
Ideal boiler installed by Vantage in a fitted cupboard, with copper pipework and a magnetic system filter
One of our boiler installations: an Ideal combi in a fitted cupboard with a magnetic system filter.

New boiler?

Get an instant estimate for a new boiler

Answer a few questions about your home online and see your estimate straight away, fitted by our own engineers.

Instant boiler estimateOr call 01462 506 374

What boiler electrodes do

Every time your boiler fires, a short sequence runs in a few seconds. The fan starts, the gas valve opens, a spark lights the gas at the burner, and the boiler then checks that a flame is actually there. If it cannot confirm a flame within its safety time, it shuts the gas off and tries again or locks out. Electrodes handle the spark and the check.

The ignition electrode

The ignition electrode is a metal rod held in a ceramic insulator, set a precise distance from the burner or from a second electrode. The boiler’s ignition unit sends a high voltage to it, and a spark jumps the gap and lights the gas and air mixture. That is the clicking you sometimes hear when a boiler starts.

The flame sensing electrode

The flame sensing electrode (also called the flame rectification or ionisation electrode) sits in the flame. A lit gas flame conducts a very small electric current. The control board measures that current through the electrode, and as long as it sees it, it knows there is a flame and keeps the gas valve open. If the current drops away, it closes the gas valve within seconds. This is one of the boiler’s most important safety features, because it stops unburnt gas building up.

Combined electrodes

Some boilers use a single electrode for both jobs, or a combined assembly with two probes on one mounting. The principle is the same.

If your boiler is locking out and you want it sorted, our boiler repair service covers all the major brands, with the phone answered 24 hours a day, 7 days a week.

Signs an electrode may be failing

  • The boiler clicks but does not light, then locks out.
  • It lights, then cuts out after a few seconds, because the flame is not being detected.
  • It takes several attempts to light, sometimes with a louder ignition than usual.
  • It works one day and not the next, especially when the electrode is on its way out.
  • An ignition or flame fault code. Examples include Vaillant F28 (failed to light), Vaillant F29 (flame lost during operation), Ideal L2 (ignition lockout), Worcester Bosch EA (no flame detected) and Baxi E133.

None of these signs prove the electrode is at fault. The same codes appear when gas is not reaching the boiler, when the condensate pipe is frozen, or when the flue or air supply is blocked. That is why the simple checks come first.

Check these first

These checks are safe and do not involve opening the boiler.

  1. Check the gas is on. Try the hob or another gas appliance. If you have a prepayment meter, make sure it has credit.
  2. Check the condensate pipe in cold weather. A frozen condensate pipe is one of the most common reasons for an ignition lockout in winter. Thaw it with warm (not boiling) water. Our frozen condensate pipe guide shows how.
  3. Check the flue terminal outside is not blocked by leaves, a nest or an object pushed against it. Look, but do not touch or dismantle it.
  4. Check the power. Make sure the fused spur is on and the display is lit.
  5. Reset once or twice. Use the reset button as your user guide describes. If the same code keeps returning, stop and call an engineer.

What not to do

  • Do not remove the boiler casing or touch the electrodes, burner, gas valve, fan, ignition leads or control board. Under the Gas Safety (Installation and Use) Regulations 1998 only a Gas Safe registered engineer may work on a gas appliance.
  • Do not keep resetting a boiler that will not light. Each attempt releases gas into the combustion chamber before it is proved to be lit.
  • If you smell gas, call the National Gas Emergency Service on 0800 111 999, open doors and windows, do not use electrical switches and turn the gas off at the meter if it is safe to do so.

Why electrodes fail

CauseWhat happensWhat you might noticeWhat the engineer does
Normal wearThe tip erodes with every spark and years of heatSlow or unreliable lighting on an older boilerReplaces the electrode and its seal
Deposits on the probeA coating builds up and weakens the flame signalLights, then cuts out after a few secondsCleans or replaces it, as the manufacturer’s service instructions say
Wrong gap or bent electrodeThe spark is weak or jumps to the wrong placeClicks without lightingReplaces or sets it to the manufacturer’s measurement
Cracked ceramic insulatorThe spark tracks to earth instead of the burnerClicking but no ignition, sometimes intermittentReplaces the electrode
Damaged lead or loose connectionThe high voltage or the flame signal does not get throughIntermittent lockoutsReplaces the lead or remakes the connection
Poor earthThe flame signal cannot be measured properlyFlame loss faults with a good-looking flameChecks and repairs the earth path
Combustion problemThe flame is not sitting on the electrode properlyRepeated flame lossChecks gas pressure, the flue and combustion readings

A faulty ignition unit, gas valve or control board can produce the same symptoms, which is why an engineer tests rather than guesses.

What an engineer will check

A Gas Safe engineer will normally:

  • Read the fault history, if the boiler stores one.
  • Check the gas pressure at the meter and at the boiler.
  • Check the condensate route, flue and air intake.
  • Open the sealed case and inspect the electrodes, their position, gap, insulators and leads.
  • Measure the flame signal, where the boiler allows it, to see whether it is strong enough.
  • Replace the electrode with the correct manufacturer’s part and a new seal or gasket.
  • Run a combustion analysis to confirm the boiler is burning safely before handing it back.

On many boilers the electrodes are checked as part of the annual service. A weak or worn electrode is often spotted before it causes a breakdown, which is one good reason to keep up with boiler servicing.

Repair or replace?

An electrode is a relatively small part. On a boiler that is otherwise in good condition, replacing it is a normal repair, not a reason to replace the boiler. The picture changes only if the electrode is one of several faults, or if the boiler is old and parts are becoming hard to get. If that is the case, the engineer should explain the options plainly before any work is done.

What it costs with Vantage

In normal working hours there is no call-out fee. Gas faults start with a fixed-price Gas Safe diagnostic visit, and if we can fix it on the same visit, part of that diagnostic charge comes off the repair. After the first hour, time is charged in half-hour steps, and parts are quoted before we fit them. Evening, weekend and overnight visits are charged at the out-of-hours rates. Every rate is published on our prices page, so you know what you will pay before we arrive.

Frequently asked questions

How do I know if my boiler electrode is faulty?

The usual signs are a boiler that clicks without lighting, lights and then cuts out, or shows an ignition or flame loss code. Because a gas supply problem or frozen condensate pipe can cause the same symptoms, rule those out first, then have an engineer test the electrode.

Can I clean a boiler electrode myself?

No. The electrodes are inside the sealed combustion chamber, and opening it is work on a gas appliance that only a Gas Safe registered engineer may do. The seal must also be replaced and the combustion checked afterwards.

How long do boiler electrodes last?

It varies with the boiler, how often it starts and the condition of the combustion. Many last for years, and they are inspected at each annual service, so wear is often picked up before it causes a lockout.

What is the difference between an ignition electrode and a flame sensor?

The ignition electrode makes the spark that lights the gas. The flame sensing electrode sits in the flame and lets the control board confirm the flame is there. Some boilers combine both jobs in one electrode.

Why does my boiler light and then go out?

Often because the boiler cannot detect the flame, which can be a worn or dirty flame sensing electrode, a poor connection or earth, or a combustion problem. A frozen condensate pipe or low gas pressure can cause the same thing, so check those first.

Help with ignition faults in Hertfordshire, Bedfordshire and Cambridgeshire

If your boiler keeps failing to light or cuts out after lighting, a Gas Safe engineer can test the electrodes, ignition and gas supply and put it right. We are Gas Safe registered (956889), based in Stevenage, with 24/7 emergency cover. Book through our boiler repair page or call 01462 506374.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.