Yes, an unvented hot water cylinder can be installed in a loft, as long as the loft floor can carry its full weight, there is safe access for servicing, the safety discharge pipe can be run to a safe and visible point outside, and the cylinder and pipework are protected from frost. It must be fitted by an installer qualified for unvented systems, and it is notifiable building work, so it cannot be treated as a DIY job or a quick swap.
In short
- It is allowed, but the loft has to be suitable. Many are not without some work first.
- A full cylinder weighs its capacity in kilograms of water plus the cylinder itself, so the joists and platform must be checked.
- The tundish must be in the same space as the cylinder, and the discharge pipe must fall continuously to a safe outside point.
- You need proper access, boarding and lighting, because an unvented cylinder needs an annual check.
- Mains pressure drops as the water climbs, and long pipe runs from a loft mean a longer wait for hot water.
- Installation must be by a competent person and notified to building control, which a registered installer does for you.

Hot water cylinder or cold water tank?
People searching for a “hot water tank in the loft” usually mean one of two things, and it is worth being clear which.
- A cold water storage tank is the plastic or older galvanised tank found in many lofts. It feeds a traditional vented hot water cylinder in the airing cupboard below, and sometimes the cold taps upstairs. This setup is gravity fed, which is why it often gives weak showers.
- An unvented cylinder is a sealed hot water cylinder fed directly from the mains. It does not need a tank in the loft at all, which is why people choose one to get mains pressure hot water and free up the loft.
Putting an unvented cylinder in the loft is less common than putting it in an airing cupboard, a utility room or a garage, but it is sometimes the only place it will fit, especially when a home has no airing cupboard left after a previous combi install. Our unvented cylinders page explains how they work and when they suit a home.
What makes a loft suitable
The floor must carry the weight
A litre of water weighs a kilogram, so a 210 litre cylinder holds 210kg of water before you add the weight of the cylinder, its fittings and the insulation. That load sits on a small footprint. Ceiling joists in many homes were never designed for it, so the joists and the platform the cylinder stands on need checking, and often strengthening, before installation. If there is any doubt, a structural engineer should confirm what is needed.
There must be safe access
An unvented cylinder has safety devices that need checking every year, and its expansion vessel, valves and controls need servicing. That means proper loft access (usually a fixed loft ladder), boarded walkways to the cylinder, and permanent lighting. A cylinder that an engineer cannot safely reach is a cylinder that will not be maintained.
The discharge pipe has to be possible
This is the part that rules out many lofts. Every unvented cylinder has a temperature and pressure relief valve that can release very hot water if something fails. Building regulations guidance (Approved Document G) sets out how that water must be carried away:
- The tundish, where discharge becomes visible, must be vertical, in the same space as the cylinder, lower than the safety valve and close to it.
- Below the tundish, the discharge pipe needs a vertical section of at least 300mm before any bend, then a continuous fall of at least 1 in 200.
- The pipe gets larger the longer it runs, to keep the resistance within limits.
- It must end somewhere safe and visible, such as a trapped gully below a grating, at low level just above the ground, or at high level into a metal hopper and downpipe or onto a roof that can take very hot water, well away from plastic guttering.
From a loft, getting a pipe that falls all the way to a safe termination can mean a long route through the house or a carefully planned exit at the eaves. If it cannot be done properly, the loft is not the right place.
Frost and heat loss
Most lofts are cold, because the insulation sits between the ceiling joists below them. A cylinder and its pipework above that insulation need protecting from frost, and a hot cylinder in a cold space loses more heat than one inside the house. A well-insulated cylinder and lagged pipework reduce this, but the loss is never zero.
Pressure and the wait for hot water
Mains pressure drops by roughly 0.1 bar for every metre the water has to climb. A cylinder two floors up starts with less incoming pressure than one on the ground floor, and manufacturers set a minimum incoming pressure and flow for their cylinders. The pipe runs from a loft down to the kitchen can also be long, so you wait longer for hot water at the far taps. If your mains is already weak at ground level, our guide to low water pressure in the whole house explains what can be done about it first.
Loft or somewhere else? A quick comparison
| Location | Advantages | Things to check |
|---|---|---|
| Airing cupboard | Warm, easy access, short pipe runs, discharge route often simple | Space, and the floor if the cylinder is larger than the old one |
| Utility room or garage | Plenty of space, easy access | Frost in a garage, pipe run lengths |
| Loft | Frees up living space | Floor strength, access, discharge route, frost, pressure at height |
| No cylinder (combi) | No storage needed at all | Only suits homes where one outlet is used at a time |
If you have the option, most engineers will recommend an airing cupboard or utility space over a loft. A loft is a workable choice when it is the only realistic space and it passes the checks above. Whoever you use, our guide on how to choose a plumber in Hertfordshire lists the questions worth asking before you agree to the work.
Horizontal cylinders for low lofts
Some manufacturers make horizontal unvented cylinders for spaces without the height for an upright one. They still need the same safety devices, discharge arrangement, support and access, and their installation instructions will set out how they must be mounted.
Why this is not a DIY job
- Building regulations require unvented systems to be installed by a competent person, shown by membership of a competent person scheme for this work or a current skills card for unvented systems.
- Installing an unvented system is notifiable building work. Building control must be told before work starts, unless your installer is registered to self-certify it.
- Never cap, block or reroute a relief valve discharge pipe. It is there to release scalding water safely if a control fails.
- If you see water running from the tundish or the discharge pipe outside, turn off the heat source to the cylinder and call an engineer.
What the installer will check on a survey
- The loft floor, joists and the space for a platform
- Access, boarding and lighting
- A workable route for the discharge pipe with the right fall and termination
- Incoming mains pressure and flow at the point of entry
- Where the boiler, immersion heater and controls will connect
- Frost protection for the cylinder and every pipe in the cold space
- Whether the water company needs to be notified, which the installer handles
A cylinder in a loft sits above living space. Any leak shows up through a ceiling, so a good installation also plans how a leak would be noticed. If you already have water marks on an upstairs ceiling, our leak detection service can find the source.
How we price it
Installations are quoted as a fixed price after a free survey, so the price you agree is the price you pay. The survey is where we find out whether your loft is suitable, what strengthening or access work is needed and how the discharge pipe would run. Our published rates for other work are on our prices page.
If you are changing your boiler at the same time, you can get a price for the boiler with our boiler quote tool, and we will cover the cylinder on the survey.
Frequently asked questions
Can a hot water tank go in the loft?
A hot water cylinder can go in a loft if the floor is strong enough, there is safe access, it is protected from frost and the discharge pipe can be run safely. For an unvented cylinder, the installer must be qualified for unvented work and the job must be notified to building control.
Do I need building regulations approval for an unvented cylinder in the loft?
Installing an unvented cylinder is notifiable building work wherever it goes. A registered installer can self-certify the work and notify building control for you. Otherwise building control must be told before work starts.
How much does a full hot water cylinder weigh?
Each litre of water weighs a kilogram, so a 150 litre cylinder carries 150kg of water and a 250 litre cylinder 250kg, plus the weight of the cylinder itself. That is why the loft floor must be checked.
Will I get good pressure from an unvented cylinder in the loft?
It runs at mains pressure, reduced a little by the height it sits at. If your incoming mains is strong, you will usually get good pressure. If it is weak, the installer will test it on the survey, because the cylinder can only deliver what the mains supplies.
Can I move my old cold water tank out of the loft?
When you switch to an unvented cylinder or a combi, the cold water tank and feed and expansion tank in the loft are usually no longer needed and can be removed. The old vented cylinder is usually removed too.
Hot water cylinder installation in Hertfordshire
If you are thinking about a cylinder in the loft, or want to know whether your home suits unvented hot water at all, we will survey it and give you an honest answer. We cover Hertfordshire, Bedfordshire and Cambridgeshire from our base in Stevenage. See our unvented cylinders page or call 01462 506374.
What our customers say
Speak to a local engineer
Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.
Gas Safe registered, number 956889. Emergency line answered 24/7.
Boiler engineers near you
Boiler playing up? Book a local Gas Safe engineer
We cover Hertfordshire, Bedfordshire and Cambridgeshire. Choose your town:
Not listed? See all the areas we cover or call 01462 506 374