Combi Boiler Flow Rate Explained: What You Need and How to Check It

Hertfordshire, Bedfordshire & Cambridgeshire

Fully Stocked Vans12 Month Labour GuaranteeGas Safe Registered 956889

A combi boiler’s flow rate is how many litres of hot water a minute it can deliver, usually quoted at a 35°C temperature rise, and most domestic combis sit somewhere between about 10 and 16 litres a minute. The figure you actually get at the tap is limited by two things: the boiler’s hot water output in kW and the flow of cold mains water coming into your home, so a big combi on a weak mains supply will not perform any better than a smaller one.

In short

  • Flow rate is litres per minute of hot water at a stated temperature rise, normally 35°C.
  • The boiler’s hot water output decides it: roughly 24kW gives about 10 litres a minute, 30kW about 12 and 35kW about 14.
  • Your incoming mains flow is the ceiling. If the mains cannot supply more, a bigger combi will not help.
  • In winter the mains is colder, so the same boiler gives slightly less hot water at the same temperature.
  • A combi serves one outlet well. Two showers at once halves what each one gets.
  • Test your mains with a bucket and a timer before choosing a boiler size.
Ideal boiler installed by Vantage in a fitted cupboard, with copper pipework and a magnetic system filter
One of our boiler installations: an Ideal combi in a fitted cupboard with a magnetic system filter.

What flow rate means on a combi boiler

A combi heats mains water as it passes through, with no stored hot water. The flow rate on the data sheet tells you how much water it can heat per minute by a set amount, which is almost always 35°C. That figure is chosen because mains water in the UK arrives at around 10°C for much of the year, and 10°C plus 35°C gives 45°C, a comfortable hot tap or shower temperature.

When you see “12.2 litres per minute” on a boiler spec, it means: at full hot water output, this boiler can raise 12.2 litres of water every minute by 35°C. It does not mean every tap in the house will run at 12.2 litres a minute.

How kW turns into litres per minute

The hot water flow rate follows directly from the boiler’s hot water output. Heating one litre of water by one degree takes a fixed amount of energy, so the calculation is simple physics.

Hot water outputApproximate flow at 35°C riseApproximate flow at 40°C rise (cold winter mains)
24kW9.8 litres a minute8.6 litres a minute
28kW11.5 litres a minute10.0 litres a minute
30kW12.3 litres a minute10.8 litres a minute
35kW14.3 litres a minute12.5 litres a minute
40kW16.4 litres a minute14.3 litres a minute

Manufacturers’ published figures land very close to these numbers. Note that many combis have a higher hot water output than heating output. A boiler sold as a “30” is usually rated around 30kW for hot water and less for the radiators.

Why your mains supply matters more than the boiler

A combi can only heat the water it receives. If your mains delivers 9 litres a minute at the kitchen tap, a boiler rated for 16 litres a minute still gives you about 9, just hotter.

This is why a proper survey for a new combi boiler starts with a flow test, not a brochure. It is also why a friend’s combi may run a great shower while the same model in your house does not.

Pressure and flow are different things. Pressure (in bar) is the push behind the water when nothing is running. Flow (in litres a minute) is how much actually comes out when a tap is open. A supply can show good pressure on a gauge and still give poor flow because of a narrow or old supply pipe, a partly closed stopcock or a long shared supply. If flow is weak across the whole house, our guide to low water pressure in the whole house explains the usual causes.

How to test your mains flow rate

You can get a good idea of your flow with a bucket and a phone timer.

  1. Make sure no other taps, showers, toilets or appliances are using water.
  2. Use the kitchen cold tap, which is normally fed directly from the mains.
  3. Open the tap fully.
  4. Time how long it takes to fill a container of known size, such as a 10 litre bucket.
  5. Divide 600 by the number of seconds. That is your flow in litres per minute. Filling 10 litres in 50 seconds gives 12 litres a minute.
  6. Repeat with another tap running at the same time to see how much the flow drops when two outlets are open.

Do it at a busy time of day too. Flow can drop in the morning when the whole street is using water.

How much flow rate do you need?

It depends on how many people want hot water at the same time, not on the size of the house.

HomeWhat usually worksNotes
Flat or small house, one bathroomCombi with around 10 to 12 litres a minuteGood choice where only one outlet is used at a time
Family home, one bathroom plus en suiteLarger combi, around 14 litres a minute or more, on a strong mainsTwo showers at once will still share the flow
Two or more bathrooms used togetherSystem boiler with an unvented cylinderStored hot water copes better with several outlets at once

One boiler manufacturer’s advice is that a good shower from a combi needs at least 12 to 15 litres a minute. A mixer shower also blends in cold water, so the hot flow a shower needs depends on the temperature you set and the shower head.

If your home regularly runs two showers at once, a combi is often the wrong tool. A system boiler with an unvented cylinder stores hot water at mains pressure and can supply more than one outlet without the drop.

Can you increase a combi’s flow rate?

Sometimes. What helps depends on where the limit is.

  • If the mains is the limit: a wider supply pipe from the stopcock, a fully open stopcock or a new mains connection can help. A pump or booster fitted to the supply is controlled by the water regulations, and one drawing more than 12 litres a minute must be notified to your water company first, so speak to a plumber before buying one.
  • If the boiler is the limit: a larger output combi, as long as the mains can keep up.
  • If flow varies or the hot water goes lukewarm: the problem may be the boiler rather than its size. A scaled heat exchanger, a sticking diverter valve or a faulty flow sensor all reduce hot water performance. That is a repair job, not a sizing one.
  • If the shower is weak but taps are fine: a clogged shower head, a restrictor in the shower hose or a thermostatic valve that needs servicing are more likely culprits.

Some combis have a flow restrictor or an adjustable hot water setting that an engineer can change. It is set for a reason: restricting flow keeps the water hot enough at the outlet, so opening it up on a weak boiler just gives more lukewarm water.

For shower-specific problems, see our guide to a shower running hot and cold.

Hard water and flow rate Hard water across most of Hertfordshire leaves limescale on the plate heat exchanger inside a combi over time. As it builds up, the boiler struggles to heat water at its rated flow. A combi that used to give hot water at full flow and now only manages it with the tap half open is worth having checked.

Choosing the right combi for your flow

  • Test your mains flow before you choose a size.
  • Match the boiler to what the mains can deliver, with a little headroom for winter.
  • Think about how many outlets are used together, not how many bathrooms you have.
  • If two showers at once is normal in your house, consider a system boiler and cylinder instead.
  • Compare published hot water flow rates at the same temperature rise. Our guide to the best combi boilers covers the models we recommend.

When we survey for a new boiler, we check your flow and the number of outlets used together before recommending a size.

How we price it

Installations are quoted as a fixed price after a free survey, so the price you agree is the price you pay. You can get your price online in a couple of minutes with our boiler quote tool. Our published rates for repairs and diagnostic visits are on our prices page.

Trusted & Accredited Professionals
Checkatrade approved trader
City and Guilds qualified engineers
BPEC certified engineers
Gas Safe registered engineers
Elite CHAS accreditation
London and South East England Prestige Awards 2022 winner
Veriforce CHAS accredited contractor

Frequently asked questions

What is a good flow rate for a combi boiler?

For a home where one shower or tap is used at a time, around 10 to 12 litres a minute at a 35°C rise is usually comfortable. Larger homes with an en suite benefit from 14 litres a minute or more, provided the mains supply can deliver it.

What is the flow rate of a 24kW combi?

A 24kW hot water output gives roughly 9.8 litres a minute at a 35°C temperature rise. In winter, when the mains is colder, expect a little less at the same outlet temperature.

How do I know the flow rate of my boiler?

Look for the model name on the front or underneath the boiler and find the data sheet or installation manual. The hot water flow rate is usually listed in litres a minute at a 35°C rise, next to the hot water output in kW.

Does a bigger combi boiler give better water pressure?

Not on its own. A bigger combi can heat more water per minute, but it cannot increase the flow coming in from the mains. If your mains flow is low, fix that first or consider a stored hot water system.

Why is my combi hot water good in summer but weaker in winter?

In winter the mains water arrives colder, so the boiler has to raise it by more degrees. With the same output, it can heat fewer litres a minute to the same temperature, so the flow at a comfortable temperature drops.

Help choosing the right boiler in Hertfordshire

If you are not sure whether a combi suits your home, or which size to choose, we will test your supply and recommend the right system on a free survey. We cover Hertfordshire, Bedfordshire and Cambridgeshire from our base in Stevenage. See our boiler installation page or call 01462 506374.

Rather have an engineer look at it?

Call the office, message us on WhatsApp or ask for a callback. We cover Hertfordshire, Bedfordshire and the surrounding areas.

Why choose Vantage

Rated 4.9 on Google from more than 700 reviews across Google, Checkatrade and Trustatrader. Qualified, accredited engineers, a fixed price before any work begins and a labour guarantee on every job, from an established local company with an office team you can actually reach. No job too small.

The Vantage Plumbing and Heating fleet of five fully stocked liveried vans

Gas Safe registered

Company registration 956889. Every gas engineer carries their own Gas Safe ID card, and you can ask to see it.

Refcom F-Gas certified

REF1024550. Legally required for air conditioning installation and servicing, and we hold it.

CHAS Elite accredited

Veriforce CHAS assessed for health and safety, which is why commercial clients and landlords use us.

City & Guilds and BPEC qualified

Qualified, insured engineers on every job. No subcontracted strangers.

700+ reviews, 4.9 on Google

Across Google, Checkatrade and Trustatrader. Read them before you book.

Labour guarantee on every job

12 months on repairs, installations and everything else. Two years on a full bathroom refit. If anything we did develops a fault, we come back and put it right.

Fixed price before we start

The price is agreed with you before any work begins. No hidden extras on the invoice.

24/7, answered by a person

The emergency line is answered every day of the year by someone who can send an engineer, not a call centre.

Fully stocked vans

Five vans carrying the parts that fail most often, so most jobs are fixed on the first visit.

An office team behind every job

An established local business with multiple engineers and a dedicated office team to keep you informed.

Vaillant myREWARDS and Ideal Max accredited

Accredited installer status means extended manufacturer warranties on the boilers we fit.

Emergency response within the hour

Our average response to an emergency call is under an hour across Hertfordshire, Bedfordshire and Cambridgeshire.

What our customers say

Speak to a local engineer

Vantage Plumbing and Heating covers Hertfordshire, Bedfordshire and the surrounding areas. Call and talk to an engineer, or send us the details and we will come back to you with a price.

Gas Safe registered, number 956889. Emergency line answered 24/7.

Quick check

Do we cover your postcode?

We work across Hertfordshire, Bedfordshire, Cambridgeshire, Milton Keynes and North, East and West London, including Hitchin, Stevenage, St Albans, Luton and Cambridge. Pop your postcode in and see straight away.

If we cover you, tell us what you need and how soon, and we will ring you back. Prefer to talk now? Call 01462 506 374, answered by a person 24/7.

✓ Yes, we cover you. Fill in the short form below and we will ring you back.
We might not cover your area yet. Send it anyway: fill in the short form below and we will ring you back and tell you honestly whether we can reach you.
Sorry, we do not work in South London. For anything else, ring 01462 506 374.